These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 1947332)
41. Measurement of masticatory forces and implant loads: a methodologic clinical study. Morneburg TR; Pröschel PA Int J Prosthodont; 2002; 15(1):20-7. PubMed ID: 11887595 [TBL] [Abstract][Full Text] [Related]
42. Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures. Falk H; Laurell L; Lundgren D Int J Oral Maxillofac Implants; 1989; 4(1):55-62. PubMed ID: 2689336 [TBL] [Abstract][Full Text] [Related]
43. [Cantilever resin-bonded bridges with one adhesive surface. A review of the literature]. van Dalen A; Feilzer AJ Ned Tijdschr Tandheelkd; 2003 Apr; 110(4):143-8. PubMed ID: 12723291 [TBL] [Abstract][Full Text] [Related]
44. Effect of magnetic attachment with stress breaker on lateral stress to abutment tooth under overdenture. Gonda T; Ikebe K; Ono T; Nokubi T J Oral Rehabil; 2004 Oct; 31(10):1001-6. PubMed ID: 15387841 [TBL] [Abstract][Full Text] [Related]
45. [Analysis of stresses in modified resin-bonded cast fixed partial dentures]. Yurdukoru B; Uçtaşli S Ankara Univ Hekim Fak Derg; 1990 Jan; 17(1):91-8. PubMed ID: 2104064 [TBL] [Abstract][Full Text] [Related]
46. Effects of resistance form on attachment strength of resin-retained castings. Wilkes PW; Shillingburg HT; Johnson DL J Okla Dent Assoc; 2000; 90(3):16-20, 22, 24-5. PubMed ID: 11314309 [TBL] [Abstract][Full Text] [Related]
48. Multiple cantilevers: an alternative to dental implants. Schweikert ED Dent Today; 1994 Jul; 13(7):38, 40-1. PubMed ID: 9540492 [TBL] [Abstract][Full Text] [Related]
49. The use of attachments in combination implant and natural-tooth fixed partial dentures: a technical report. Cohen SR; Orenstein JH Int J Oral Maxillofac Implants; 1994; 9(2):230-4. PubMed ID: 8206560 [TBL] [Abstract][Full Text] [Related]
50. In vivo forces on implants influenced by occlusal scheme and food consistency. Morneburg TR; Pröschel PA Int J Prosthodont; 2003; 16(5):481-6. PubMed ID: 14651231 [TBL] [Abstract][Full Text] [Related]
51. [Mechanical studies on the dental bridges. (XI) Studies on the apportionment loads to be affected by the supporting conditions of two abutment teeth (author's transl)]. Miyairi H; Muramatsu A Shika Rikogaku Zasshi; 1976 Jan; 17(37):5-10. PubMed ID: 772142 [TBL] [Abstract][Full Text] [Related]
52. Distribution of occlusal forces along unilateral posterior two-unit cantilever segments in cross-arch fixed partial dentures. Laurell L; Lundgren D J Prosthet Dent; 1988 Jul; 60(1):106-12. PubMed ID: 3042968 [TBL] [Abstract][Full Text] [Related]
53. [A photoelastic study of the stress distribution in the surrounding tissues of the abutments of a fixed partial denture with tilted molar abutments]. Woo YJ; Chung HG; Jo KH Taehan Chikkwa Uisa Hyophoe Chi; 1989 Jan; 27(1):49-60. PubMed ID: 2689541 [TBL] [Abstract][Full Text] [Related]
54. [Three dimensional finite element stress analysis on superstructure of the fixed bridge supported by tooth-implant]. Wang XJ; Zhou YM; Liu HY; Wu CL Zhonghua Kou Qiang Yi Xue Za Zhi; 2003 Nov; 38(6):414-6. PubMed ID: 14703470 [TBL] [Abstract][Full Text] [Related]
55. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Rosentritt M; Behr M; Gebhard R; Handel G Dent Mater; 2006 Feb; 22(2):176-82. PubMed ID: 16039706 [TBL] [Abstract][Full Text] [Related]
56. [Measurement of bite forces in Maryland bridges using strain gauge technique]. Yurdukoru B; Kalipçilar B Ankara Univ Hekim Fak Derg; 1987 Sep; 14(3):291-7. PubMed ID: 3333913 [No Abstract] [Full Text] [Related]
57. [Stress analysis of bridge abutment teeth with cemented dowels]. Kataoka S; Iwai K; Ishihara Y; Amari M; Ohshima K Nihon Hotetsu Shika Gakkai Zasshi; 1990 Feb; 34(1):175-85. PubMed ID: 2134918 [TBL] [Abstract][Full Text] [Related]
58. The osteointegrated prosthesis--combination of osteointegrated implants and natural teeth in fixed prostheses. Bechelli AH J Oral Implantol; 1992; 18(1):62-5. PubMed ID: 1289544 [No Abstract] [Full Text] [Related]
59. Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments. Wright KW; Yettram AL J Prosthet Dent; 1979 Oct; 42(4):411-6. PubMed ID: 385842 [TBL] [Abstract][Full Text] [Related]
60. [Measuring three-dimensional displacement of tooth-supported rigid fixed bridge under oblique concentrated loading using digital laser speckle photography]. Xu ZJ; Chen XM; Li AJ; Chen Y; Peng ZZ; Wang J Sichuan Da Xue Xue Bao Yi Xue Ban; 2013 Jan; 44(1):99-103. PubMed ID: 23600220 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]