These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 19475241)

  • 1. [Airflow resistance of double-lumen tracheal tubes.].
    Lustosa KC; Schalch E; Vieira JE; Benseñor FE
    Rev Bras Anestesiol; 2002 Nov; 52(6):700-6. PubMed ID: 19475241
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Airway ventilation pressures during bronchoscopy, bronchial blocker, and double-lumen endotracheal tube use: an in vitro study.
    Kuo AS; Philip JH; Edrich T
    J Cardiothorac Vasc Anesth; 2014 Aug; 28(4):873-9. PubMed ID: 24021918
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Airflow resistance of shortened tracheal tubes.].
    Prado FJ; Vieira JE; Benseñor FE
    Rev Bras Anestesiol; 2004 Apr; 54(2):212-7. PubMed ID: 19471728
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow resistances of disposable double-lumen, single-lumen, and Univent tubes.
    Slinger PD; Lesiuk L
    J Cardiothorac Vasc Anesth; 1998 Apr; 12(2):142-4. PubMed ID: 9583542
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of the flow-resistive properties of double-lumen bronchial tubes in vitro.
    Chiaranda M; Rossi A; Manani G; Pinamonti O; Braschi A
    Anaesthesia; 1989 Apr; 44(4):335-40. PubMed ID: 2719208
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system.
    Banner MJ; Blanch PB; Kirby RR
    Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tracheal pressure control provides automatic and variable inspiratory pressure assist to decrease the imposed resistive work of breathing.
    Banner MJ; Blanch PB; Gabrielli A
    Crit Care Med; 2002 May; 30(5):1106-11. PubMed ID: 12006809
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of a gas leak around the endotracheal tube on the mean tracheal pressure during mechanical ventilation.
    Pérez Fontán JJ; Heldt GP; Gregory GA
    Am Rev Respir Dis; 1985 Aug; 132(2):339-42. PubMed ID: 4026056
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On some factors determining the pressure drop across tracheal tubes during high-frequency percussive ventilation: a flow-independent model.
    Lucangelo U; Ajčević M; Lena E; Ferluga M; Comuzzi L; Accardo A; Zin WA
    J Clin Monit Comput; 2021 Aug; 35(4):885-890. PubMed ID: 32588314
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tracheostomy Tube Type and Inner Cannula Selection Impact Pressure and Resistance to Air Flow.
    Pryor LN; Baldwin CE; Ward EC; Cornwell PL; O'Connor SN; Chapman MJ; Bersten AD
    Respir Care; 2016 May; 61(5):607-14. PubMed ID: 26860399
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The esophageal-tracheal combitube resistance and ventilatory pressures.
    Gaitini LA; Vaida SJ; Mostafa S; Yanovski B; Ben-David B; Benumof JL
    J Clin Anesth; 2005 Feb; 17(1):26-9. PubMed ID: 15721726
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Compensating Artificial Airway Resistance via Active Expiration Assistance.
    Wirth S; Seywert L; Spaeth J; Schumann S
    Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of hypercapnia and flow-resistive loading on tracheal pressure during airway occlusion.
    Altose MD; Kelsen SG; Stanley NN; Cherniack NS; Fishman AP
    J Appl Physiol; 1976 Mar; 40(3):345-51. PubMed ID: 931848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Guidelines for inspiratory flow setting when measuring the pressure-volume relationship.
    Bensenor FE; Vieira JE; Auler JO
    Anesth Analg; 2003 Jul; 97(1):145-50, table of contents. PubMed ID: 12818957
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characteristics of Double-Lumen Tubes Determine Bronchial Airway Pressure.
    Spaeth J; Hojnik A; Ott M; Wirth S; Schneider M; Loop T; Schumann S
    J Cardiothorac Vasc Anesth; 2016 Aug; 30(4):954-60. PubMed ID: 27521966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changes in resistances of endotracheal tubes with reductions in the cross-sectional area.
    El-Khatib MF; Husari A; Jamaleddine GW; Ayoub CM; Bou-Khalil P
    Eur J Anaesthesiol; 2008 Apr; 25(4):275-9. PubMed ID: 18177540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental study of double-lumen, two-stage endotracheal tube during conventional mechanical ventilation in rabbits.
    Chen XN; Wu JC; Geng R; Zhang XP
    Crit Care Med; 1997 Mar; 25(3):492-5. PubMed ID: 9118667
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Airway resistance and work of breathing in tracheostomy tubes.
    Mullins JB; Templer JW; Kong J; Davis WE; Hinson J
    Laryngoscope; 1993 Dec; 103(12):1367-72. PubMed ID: 8246657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size.
    Eberle B; Weiler N; Vogel N; Kauczor HU; Heinrichs W
    J Cardiothorac Vasc Anesth; 1999 Oct; 13(5):532-7. PubMed ID: 10527220
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tracheal tube resistance and airway and alveolar pressures during mechanical ventilation in the neonate.
    Tipping TR; Sykes MK
    Anaesthesia; 1991 Jul; 46(7):565-9. PubMed ID: 1862898
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.