BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

275 related articles for article (PubMed ID: 19482857)

  • 41. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.
    Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y
    J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes.
    Suehiro K; Tanaka K; Funao T; Matsuura T; Mori T; Nishikawa K
    Br J Anaesth; 2013 Aug; 111(2):170-7. PubMed ID: 23479677
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.
    Smetkin AA; Hussain A; Fot EV; Zakharov VI; Izotova NN; Yudina AS; Dityateva ZA; Gromova YV; Kuzkov VV; Bjertnæs LJ; Kirov MY
    J Clin Monit Comput; 2017 Apr; 31(2):361-370. PubMed ID: 26951494
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery.
    Greiwe G; Peters V; Hapfelmeier A; Romagnoli S; Kubik M; Saugel B
    J Clin Monit Comput; 2020 Aug; 34(4):643-648. PubMed ID: 31456071
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients.
    van Drumpt A; van Bommel J; Hoeks S; Grüne F; Wolvetang T; Bekkers J; Ter Horst M
    BMC Anesthesiol; 2017 Mar; 17(1):42. PubMed ID: 28288587
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Clinical evaluation of intraoperative cardiac output measurement by a new arterial pressure waveform analysis method( FloTrac/Vigileo) in open heart surgery].
    Furukawa H; Ohkado A; Nagashima M; Ohsawa H; Ichikawa S
    Kyobu Geka; 2013 Aug; 66(9):775-83. PubMed ID: 23917227
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients.
    Monnet X; Anguel N; Jozwiak M; Richard C; Teboul JL
    Br J Anaesth; 2012 Apr; 108(4):615-22. PubMed ID: 22265900
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution.
    Hamm JB; Nguyen BV; Kiss G; Wargnier JP; Jauffroy A; Helaine L; Arvieux CC; Gueret G
    Anaesth Intensive Care; 2010 Mar; 38(2):295-301. PubMed ID: 20369763
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage.
    Mutoh T; Ishikawa T; Nishino K; Yasui N
    J Neurosurg Anesthesiol; 2009 Jul; 21(3):218-25. PubMed ID: 19542999
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution.
    Mekis D; Kamenik M; Starc V; Jeretin S
    Eur J Anaesthesiol; 2008 Mar; 25(3):237-42. PubMed ID: 17850685
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor.
    Zimmermann A; Kufner C; Hofbauer S; Steinwendner J; Hitzl W; Fritsch G; Schistek R; Kirnbauer M; Pauser G
    J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):388-93. PubMed ID: 18503926
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.
    Button D; Weibel L; Reuthebuch O; Genoni M; Zollinger A; Hofer CK
    Br J Anaesth; 2007 Sep; 99(3):329-36. PubMed ID: 17631509
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Cardiac output measurement by arterial waveform analysis in cardiac surgery--a comparison of measurements derived from waveforms of the radial artery versus the ascending aorta.
    Sander M; Spies CD; Foer A; von Heymann C
    J Int Med Res; 2008; 36(3):414-9. PubMed ID: 18534122
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery.
    Broch O; Renner J; Gruenewald M; Meybohm P; Schöttler J; Caliebe A; Steinfath M; Malbrain M; Bein B
    Anaesthesia; 2012 Apr; 67(4):377-83. PubMed ID: 22324797
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Accuracy of Cardiac Output Measured by Fourth-Generation FloTrac and LiDCOrapid, and Their Characteristics Regarding Systemic Vascular Resistance in Patients Undergoing Cardiac Surgery.
    Takei Y; Kumagai M; Suzuki M; Mori S; Sato Y; Tamii T; Tamii A; Saito A; Ogata Y; Kaiho Y; Toyama H; Ejima Y; Yamauchi M
    J Cardiothorac Vasc Anesth; 2023 Jul; 37(7):1143-1151. PubMed ID: 37076386
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Validation of cardiac output estimation using the fourth-generation FloTrac/EV1000™ system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery.
    Wu NH; Hsieh TH; Chang CY; Shih PC; Kao MC; Lin HY
    Heart Vessels; 2023 Mar; 38(3):341-347. PubMed ID: 36181530
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Accuracy and Trending Ability of the Fourth-Generation FloTrac/Vigileo System in Patients With Low Cardiac Index.
    Hattori K; Maeda T; Masubuchi T; Yoshikawa A; Ebuchi K; Morishima K; Kamei M; Yoshitani K; Ohnishi Y
    J Cardiothorac Vasc Anesth; 2017 Feb; 31(1):99-104. PubMed ID: 27612931
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
    Missant C; Rex S; Wouters PF
    Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
    [TBL] [Abstract][Full Text] [Related]  

  • 59. An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation.
    Scolletta S; Franchi F; Taccone FS; Donadello K; Biagioli B; Vincent JL
    Anesth Analg; 2011 Dec; 113(6):1389-95. PubMed ID: 22003226
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Uncalibrated arterial pulse cardiac output measurements in patients with moderately abnormal left ventricular function.
    Vetrugno L; Costa MG; Spagnesi L; Pompei L; Chiarandini P; Gimigliano I; Della Rocca G
    J Cardiothorac Vasc Anesth; 2011 Feb; 25(1):53-8. PubMed ID: 20850989
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.