These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 19488816)

  • 41. Conversion of temporary hemodialysis catheters to tunneled hemodialysis catheters.
    Falk A; Parthasarathy S
    Clin Nephrol; 2005 Mar; 63(3):209-14. PubMed ID: 15786822
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Comparison of Clinical Performance of VectorFlow and Palindrome Symmetric-Tip Dialysis Catheters: A Multicenter, Randomized Trial.
    Nadolski GJ; Redmond J; Shin B; Shamimi-Noori S; Vance A; Hammelman B; Clark TWI; Cohen R; Rudnick M
    J Vasc Interv Radiol; 2020 Jul; 31(7):1148-1155. PubMed ID: 32534972
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Do AshSplit haemodialysis catheters provide better flow rates in the long term?
    Keeling AN; O'Dwyer H; Lyon S; O'Kelly P; McGrath FP; Conlon PJ; Lee MJ
    Ren Fail; 2007; 29(6):721-9. PubMed ID: 17763168
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Measuring of the heparin leakage into the circulation from central venous catheters--an in vivo study.
    Markota I; Markota D; Tomic M
    Nephrol Dial Transplant; 2009 May; 24(5):1550-3. PubMed ID: 19075195
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Self-centering, split-tip catheter has better patency than symmetric-tip tunneled hemodialysis catheter: single-center retrospective analysis.
    Balamuthusamy S
    Semin Dial; 2014; 27(5):522-8. PubMed ID: 24438081
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A refinement of Hong's technique for the removal of stuck dialysis catheters: an easy solution to a complex problem.
    Quaretti P; Galli F; Fiorina I; Moramarco LP; Spina M; Forneris G; Torresi M; Bellazzi R
    J Vasc Access; 2014; 15(3):183-8. PubMed ID: 24190073
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Using tunneled femoral vein catheters for "urgent start" dialysis patients: a preliminary report.
    Hingwala J; Bhola C; Lok CE
    J Vasc Access; 2014; 15 Suppl 7():S101-8. PubMed ID: 24817465
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Tip Design of Hemodialysis Catheters Influences Thrombotic Events and Replacement Rate.
    Petridis C; Nitschke M; Lehne W; Smith E; Goltz JP; Lehnert H; Meier M
    Eur J Vasc Endovasc Surg; 2017 Feb; 53(2):262-267. PubMed ID: 27876561
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Low dose heparin lock (1000 U/mL) maintains tunnelled hemodialysis catheter patency when compared with high dose heparin (5000 U/mL): A randomised controlled trial.
    Chu G; Fogarty GM; Avis LF; Bergin S; McElduff P; Gillies AH; Choi P
    Hemodial Int; 2016 Jul; 20(3):385-91. PubMed ID: 26833752
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Concomitant placement of dialysis and infusion catheters in the right internal jugular vein in the intensive care setting: Is it safe?
    Spitzer B; Kirkland K; Reyes J; Helmer SD; Ammar C; Subbarao C
    J Vasc Access; 2021 May; 22(3):359-363. PubMed ID: 32667243
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Material thrombogenicity in central venous catheterization. I. A comparison between uncoated and heparin-coated, long antebrachial, polyethylene catheters.
    BennegÄrd K; Curelaru I; Gustavsson B; Linder LE; Zachrisson BF
    Acta Anaesthesiol Scand; 1982 Apr; 26(2):112-20. PubMed ID: 7048839
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Natural history of tunneled dialysis catheters placed for hemodialysis initiation.
    Shingarev R; Barker-Finkel J; Allon M
    J Vasc Interv Radiol; 2013 Sep; 24(9):1289-94. PubMed ID: 23871694
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Immediate-access grafts provide comparable patency to standard grafts, with fewer reinterventions and catheter-related complications.
    Wagner JK; Dillavou E; Nag U; Ali AA; Truong S; Chaer R; Hager E; Yuo T; Makaroun M; Avgerinos ED
    J Vasc Surg; 2019 Mar; 69(3):883-889. PubMed ID: 30528400
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Cathasept Line Lock and Microbial Colonization of Tunneled Hemodialysis Catheters: A Multicenter Randomized Controlled Trial.
    Kanaa M; Wright MJ; Akbani H; Laboi P; Bhandari S; Sandoe JA
    Am J Kidney Dis; 2015 Dec; 66(6):1015-23. PubMed ID: 26141306
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Longitudinal dialysis adequacy and clinical performance of the VectorFlow hemodialysis catheter: a prospective study.
    Ross JR; Puga TA; Philbeck TE
    J Vasc Access; 2017 Nov; 18(6):492-497. PubMed ID: 28862725
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The impact of catheter-restricted filling with cefotaxime and heparin on the lifespan of temporary hemodialysis catheters: a case controlled study.
    Saxena AK; Panhotra BR
    J Nephrol; 2005; 18(6):755-63. PubMed ID: 16358235
    [TBL] [Abstract][Full Text] [Related]  

  • 57. An analysis of potential predictors of tunneled hemodialysis catheter infection or dysfunction.
    Coker MA; Black JR; Li Y; Varma R; Almehmi A; Abdel Aal AK; Gunn AJ
    J Vasc Access; 2019 Jul; 20(4):380-385. PubMed ID: 30421638
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Outcome of Cuffed Tunneled Dialysis Catheters for Hemodialysis Patients at a Tertiary Care Hospital: A Descriptive Cross-sectional Study.
    Shrestha KR; Gurung D; Shrestha UK
    JNMA J Nepal Med Assoc; 2020 Jun; 58(226):390-395. PubMed ID: 32788754
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Exchange over the guidewire from non-tunneled to tunneled hemodialysis catheters can be performed without patency loss.
    Park HS; Choi J; Kim HW; Baik JH; Park CW; Kim YO; Yang CW; Jin DC
    J Vasc Access; 2018 May; 19(3):252-257. PubMed ID: 29529930
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Locking solutions for hemodialysis catheters; heparin and citrate--a position paper by ASDIN.
    Moran JE; Ash SR;
    Semin Dial; 2008; 21(5):490-2. PubMed ID: 18764795
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.