These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 19493912)

  • 1. Mechanism of attenuation of the QRS voltage in heart failure: a hypothesis.
    Madias JE
    Europace; 2009 Aug; 11(8):995-1000. PubMed ID: 19493912
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrocardiographic predictors of new-onset heart failure in men and in women free of coronary heart disease (from the Atherosclerosis in Communities [ARIC] Study).
    Rautaharju PM; Prineas RJ; Wood J; Zhang ZM; Crow R; Heiss G
    Am J Cardiol; 2007 Nov; 100(9):1437-41. PubMed ID: 17950804
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The resting electrocardiogram in the management of patients with congestive heart failure: established applications and new insights.
    Madias JE
    Pacing Clin Electrophysiol; 2007 Jan; 30(1):123-8. PubMed ID: 17241326
    [TBL] [Abstract][Full Text] [Related]  

  • 4. ECG leads I and II to evaluate diuresis of patients with congestive heart failure admitted to the hospital via the emergency department.
    Lumlertgul S; Chenthanakij B; Madias JE
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):64-71. PubMed ID: 19140915
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Larger cell size in rabbits with heart failure increases myocardial conduction velocity and QRS duration.
    Wiegerinck RF; Verkerk AO; Belterman CN; van Veen TA; Baartscheer A; Opthof T; Wilders R; de Bakker JM; Coronel R
    Circulation; 2006 Feb; 113(6):806-13. PubMed ID: 16461816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On the mechanism of augmentation of electrocardiogram QRS complexes in patients with congestive heart failure responding to diuresis.
    Madias JE
    J Electrocardiol; 2005 Jan; 38(1):54-7. PubMed ID: 15660348
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The importance of the P-waves in the differentiation of attenuation of the QRS voltage due to pericardial effusion versus due to peripheral edema.
    Madias JE
    J Card Fail; 2008 Feb; 14(1):55-60. PubMed ID: 18226774
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low QRS voltage and its causes.
    Madias JE
    J Electrocardiol; 2008; 41(6):498-500. PubMed ID: 18804788
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The synthesized vectorcardiogram resembles the measured vectorcardiogram in patients with dyssynchronous heart failure.
    Engels EB; Alshehri S; van Deursen CJ; Wecke L; Bergfeldt L; Vernooy K; Prinzen FW
    J Electrocardiol; 2015; 48(4):586-92. PubMed ID: 25900820
    [TBL] [Abstract][Full Text] [Related]  

  • 10. QRS duration, an indirect reflection of ventricular synergy, is not altered in decompensated heart failure.
    Lindberg M; Li Z; Amsterdam EA; Srivatsa U
    Crit Pathw Cardiol; 2009 Jun; 8(2):88-90. PubMed ID: 19491575
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temporal and postural variation of 12-lead high-frequency QRS electrocardiographic signals in asymptomatic individuals.
    Douglas PK; Batdorf NJ; Evans RT; Feiveson AH; Arenare B; Schlegel TT
    J Electrocardiol; 2006 Jul; 39(3):259-65. PubMed ID: 16777512
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Heart "timing" versus artery "timing". Neurovegetative effects in compensated and decompensated cardiocirculatory failure.
    Dambrosio M; Federici A
    Funct Neurol; 1991; 6(3):249-53. PubMed ID: 1743537
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standard electrocardiographic and signal-averaged electrocardiographic changes in congestive heart failure.
    Madias JE
    Congest Heart Fail; 2005; 11(5):266-71. PubMed ID: 16230869
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Why recording of an electrocardiogram should be required in every inpatient and outpatient encounter of patients with heart failure.
    Madias JE
    Pacing Clin Electrophysiol; 2011 Aug; 34(8):963-7. PubMed ID: 21605138
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An in-silico analysis of the effect of heart position and orientation on the ECG morphology and vectorcardiogram parameters in patients with heart failure and intraventricular conduction defects.
    Nguyên UC; Potse M; Regoli F; Caputo ML; Conte G; Murzilli R; Muzzarelli S; Moccetti T; Caiani EG; Prinzen FW; Krause R; Auricchio A
    J Electrocardiol; 2015; 48(4):617-25. PubMed ID: 26025201
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of lead aVR "net QRS area" and "peak-to-peak amplitude" as indices of all limb electrocardiogram leads: Implications for the diagnosis, management, and follow-up in patients with heart failure.
    Madias JE
    Med Eng Phys; 2012 Oct; 34(8):1037-40. PubMed ID: 22137676
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determinants of changes in QRS duration resulting from artificial attenuation of ECG voltage.
    Madias JE
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):442-3. PubMed ID: 16650280
    [No Abstract]   [Full Text] [Related]  

  • 18. Air pollution effects on ventricular repolarization.
    Lux RL; Pope CA
    Res Rep Health Eff Inst; 2009 May; (141):3-20; discussion 21-8. PubMed ID: 19579527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparability of the standing and supine standard electrocardiograms and standing sitting and supine stress electrocardiograms.
    Madias JE
    J Electrocardiol; 2006 Apr; 39(2):142-9. PubMed ID: 16580409
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Increased QRS voltage during dehydrating].
    Saltykova MM; At'kov OIu; Karlin EK; Zaruba AIu; Dmitriev AA; Kukharchuk VV
    Ter Arkh; 2007; 79(4):18-23. PubMed ID: 17564013
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.