These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 19494750)

  • 1. Retrieval analysis of a ProDisc-L total disc replacement.
    Choma TJ; Miranda J; Siskey R; Baxter R; Steinbeck MJ; Kurtz SM
    J Spinal Disord Tech; 2009 Jun; 22(4):290-6. PubMed ID: 19494750
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The natural history of polyethylene oxidation in total disc replacement.
    Kurtz SM; MacDonald D; Ianuzzi A; van Ooij A; Isaza J; Ross ER; Regan J
    Spine (Phila Pa 1976); 2009 Oct; 34(22):2369-77. PubMed ID: 19789469
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo functional performance of failed Prodisc-L devices: retrieval analysis of lumbar total disc replacements.
    Lebl DR; Cammisa FP; Girardi FP; Wright T; Abjornson C
    Spine (Phila Pa 1976); 2012 Sep; 37(19):E1209-17. PubMed ID: 22531474
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The mechanical performance of cervical total disc replacements in vivo: prospective retrieval analysis of prodisc-C devices.
    Lebl DR; Cammisa FP; Girardi FP; Wright T; Abjornson C
    Spine (Phila Pa 1976); 2012 Dec; 37(26):2151-60. PubMed ID: 22842559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of a retrieved polyethylene total disc replacement component.
    Kurtz SM; Peloza J; Siskey R; Villarraga ML
    Spine J; 2005; 5(3):344-50. PubMed ID: 15863092
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The lexicon of polyethylene wear in artificial joints.
    McKellop HA
    Biomaterials; 2007 Dec; 28(34):5049-57. PubMed ID: 17706766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Periprosthetic UHMWPE Wear Debris Induces Inflammation, Vascularization, and Innervation After Total Disc Replacement in the Lumbar Spine.
    Veruva SY; Lanman TH; Isaza JE; Freeman TA; Kurtz SM; Steinbeck MJ
    Clin Orthop Relat Res; 2017 May; 475(5):1369-1381. PubMed ID: 27488379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Artificial disc replacement: the new solution for discogenic low back pain?
    Shuff C; An HS
    Am J Orthop (Belle Mead NJ); 2005 Jan; 34(1):8-12. PubMed ID: 15707133
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: a study of 4 patients.
    van Ooij A; Kurtz SM; Stessels F; Noten H; van Rhijn L
    Spine (Phila Pa 1976); 2007 Jan; 32(2):223-9. PubMed ID: 17224818
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study.
    Lin CY; Kang H; Rouleau JP; Hollister SJ; Marca FL
    Spine (Phila Pa 1976); 2009 Jul; 34(15):1554-60. PubMed ID: 19564765
    [TBL] [Abstract][Full Text] [Related]  

  • 11. UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.
    Veruva SY; Lanman TH; Isaza JE; MacDonald DW; Kurtz SM; Steinbeck MJ
    Clin Orthop Relat Res; 2015 Mar; 473(3):987-98. PubMed ID: 25367112
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In situ contact analysis of the prosthesis components of Prodisc-L in lumbar spine following total disc replacement.
    Chen WM; Park C; Lee K; Lee S
    Spine (Phila Pa 1976); 2009 Sep; 34(20):E716-23. PubMed ID: 19752690
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear behaviour in total ankle replacement: a comparison between an in vitro simulation and retrieved prostheses.
    Affatato S; Taddei P; Leardini A; Giannini S; Spinelli M; Viceconti M
    Clin Biomech (Bristol, Avon); 2009 Oct; 24(8):661-9. PubMed ID: 19643517
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distinguishing wear and creep in clinically retrieved polyethylene inserts.
    McDonald MD; Bloebaum RD
    J Biomed Mater Res; 1995 Jan; 29(1):1-7. PubMed ID: 7713947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee.
    Kop AM; Swarts E
    Acta Orthop; 2007 Jun; 78(3):364-70. PubMed ID: 17611851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Periprosthetic tissue reactions observed at revision of total intervertebral disc arthroplasty.
    Punt IM; Cleutjens JP; de Bruin T; Willems PC; Kurtz SM; van Rhijn LW; Schurink GW; van Ooij A
    Biomaterials; 2009 Apr; 30(11):2079-84. PubMed ID: 19155064
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyethylene damage on the nonarticular surface of modular total knee prostheses.
    Cuckler JM; Lemons J; Tamarapalli JR; Beck P
    Clin Orthop Relat Res; 2003 May; (410):248-53. PubMed ID: 12771836
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Polyethylene disease].
    Sosna A; Radonský T; Pokorný D; Veigl D; Horák Z; Jahoda D
    Acta Chir Orthop Traumatol Cech; 2003; 70(1):6-16. PubMed ID: 12764946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical performance of contemporary tibial polyethylene components.
    Crowninshield RD; Wimmer MA; Jacobs JJ; Rosenberg AG
    J Arthroplasty; 2006 Aug; 21(5):754-61. PubMed ID: 16877165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A quantitative evaluation of inflammatory cells in human temporomandibular joint tissues from patients with and without implants.
    Alonso A; Kaimal S; Look J; Swift J; Fricton J; Myers S; Kehl L
    J Oral Maxillofac Surg; 2009 Apr; 67(4):788-96. PubMed ID: 19304036
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.