These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 19495460)

  • 21. A high throughput perfusion-based microbioreactor platform integrated with pneumatic micropumps for three-dimensional cell culture.
    Wu MH; Huang SB; Cui Z; Cui Z; Lee GB
    Biomed Microdevices; 2008 Apr; 10(2):309-19. PubMed ID: 18026840
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A microfluidic device for depositing and addressing two cell populations with intercellular population communication capability.
    Lovchik RD; Tonna N; Bianco F; Matteoli M; Delamarche E
    Biomed Microdevices; 2010 Apr; 12(2):275-82. PubMed ID: 20013313
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simple, fast and high-throughput single-cell analysis on PDMS microfluidic chips.
    Yu L; Huang H; Dong X; Wu D; Qin J; Lin B
    Electrophoresis; 2008 Dec; 29(24):5055-60. PubMed ID: 19130590
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A microfluidic cell array with individually addressable culture chambers.
    Wang HY; Bao N; Lu C
    Biosens Bioelectron; 2008 Dec; 24(4):613-7. PubMed ID: 18635348
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stable immobilization of rat hepatocytes as hemispheroids onto collagen-conjugated poly-dimethylsiloxane (PDMS) surfaces: importance of direct oxygenation through PDMS for both formation and function.
    Nishikawa M; Yamamoto T; Kojima N; Kikuo K; Fujii T; Sakai Y
    Biotechnol Bioeng; 2008 Apr; 99(6):1472-81. PubMed ID: 17969156
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An agar gel membrane-PDMS hybrid microfluidic device for long term single cell dynamic study.
    Wong I; Atsumi S; Huang WC; Wu TY; Hanai T; Lam ML; Tang P; Yang J; Liao JC; Ho CM
    Lab Chip; 2010 Oct; 10(20):2710-9. PubMed ID: 20664845
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Continuously perfused, non-cross-contaminating microfluidic chamber array for studying cellular responses to orthogonal combinations of matrix and soluble signals.
    Park ES; Brown AC; DiFeo MA; Barker TH; Lu H
    Lab Chip; 2010 Mar; 10(5):571-80. PubMed ID: 20162232
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Versatile, fully automated, microfluidic cell culture system.
    Gómez-Sjöberg R; Leyrat AA; Pirone DM; Chen CS; Quake SR
    Anal Chem; 2007 Nov; 79(22):8557-63. PubMed ID: 17953452
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Development of disposable PDMS micro cell culture analog devices with photopolymerizable hydrogel encapsulating living cells.
    Xu H; Wu J; Chu CC; Shuler ML
    Biomed Microdevices; 2012 Apr; 14(2):409-18. PubMed ID: 22160484
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Microfluidic environment for high density hepatocyte culture.
    Zhang MY; Lee PJ; Hung PJ; Johnson T; Lee LP; Mofrad MR
    Biomed Microdevices; 2008 Feb; 10(1):117-21. PubMed ID: 17682945
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development of high throughput optical sensor array for on-line pH monitoring in micro-scale cell culture environment.
    Wu MH; Lin JL; Wang J; Cui Z; Cui Z
    Biomed Microdevices; 2009 Feb; 11(1):265-73. PubMed ID: 18830696
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Microfluidic alignment of collagen fibers for in vitro cell culture.
    Lee P; Lin R; Moon J; Lee LP
    Biomed Microdevices; 2006 Mar; 8(1):35-41. PubMed ID: 16491329
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fabrication of reversibly adhesive fluidic devices using magnetism.
    Rafat M; Raad DR; Rowat AC; Auguste DT
    Lab Chip; 2009 Oct; 9(20):3016-9. PubMed ID: 19789760
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Controlled deposition of cells in sealed microfluidics using flow velocity boundaries.
    Lovchik RD; Bianco F; Matteoli M; Delamarche E
    Lab Chip; 2009 May; 9(10):1395-402. PubMed ID: 19417906
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In-situ measurement of cellular microenvironments in a microfluidic device.
    Lin Z; Cherng-Wen T; Roy P; Trau D
    Lab Chip; 2009 Jan; 9(2):257-62. PubMed ID: 19107282
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Reproducibility and robustness of a real-time microfluidic cell toxicity assay.
    Cooksey GA; Elliott JT; Plant AL
    Anal Chem; 2011 May; 83(10):3890-6. PubMed ID: 21506521
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An integrated cell culture lab on a chip: modular microdevices for cultivation of mammalian cells and delivery into microfluidic microdroplets.
    Hufnagel H; Huebner A; Gülch C; Güse K; Abell C; Hollfelder F
    Lab Chip; 2009 Jun; 9(11):1576-82. PubMed ID: 19458865
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microvalve-assisted patterning platform for measuring cellular dynamics based on 3D cell culture.
    Kim MS; Lee W; Kim YC; Park JK
    Biotechnol Bioeng; 2008 Dec; 101(5):1005-13. PubMed ID: 18942775
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Millisecond treatment of cells using microfluidic devices via two-step carrier-medium exchange.
    Yamada M; Kobayashi J; Yamato M; Seki M; Okano T
    Lab Chip; 2008 May; 8(5):772-8. PubMed ID: 18432348
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The culture and differentiation of amniotic stem cells using a microfluidic system.
    Wu HW; Lin XZ; Hwang SM; Lee GB
    Biomed Microdevices; 2009 Aug; 11(4):869-81. PubMed ID: 19370418
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.