BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 1950088)

  • 1. [The information value of the method of forced oscillations in research on respiratory mechanics].
    Baranov VM; D'iachenko AI
    Usp Fiziol Nauk; 1991; 22(3):25-40. PubMed ID: 1950088
    [No Abstract]   [Full Text] [Related]  

  • 2. Forced oscillations, interrupter technique and body plethysmography in the preschool child.
    Marchal F; Schweitzer C; Thuy LV
    Paediatr Respir Rev; 2005 Dec; 6(4):278-84. PubMed ID: 16298311
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Negative impact of the noseclip on high-frequency respiratory impedance measurements.
    Thamrin C; Albu G; Sly PD; Hantos Z
    Respir Physiol Neurobiol; 2009 Jan; 165(1):115-8. PubMed ID: 19010453
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Respiratory impedance and its in vivo distribution measured by forced complex wave oscillations].
    Kinefuchi Y; Nakamura T; Takiguchi M; Yamasaki Y; Amano M; Takaya T
    Iyodenshi To Seitai Kogaku; 1984 Apr; 22(2):117-23. PubMed ID: 6471561
    [No Abstract]   [Full Text] [Related]  

  • 5. Within- and between-day variability of respiratory impedance, using impulse oscillometry in adolescent asthmatics.
    Goldman MD; Carter R; Klein R; Fritz G; Carter B; Pachucki P
    Pediatr Pulmonol; 2002 Oct; 34(4):312-9. PubMed ID: 12205573
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variation of respiratory resistance suggests optimization of airway caliber.
    Johnson AT; Jones SC; Pan JJ; Vossoughi J
    IEEE Trans Biomed Eng; 2012 Aug; 59(8):2355-61. PubMed ID: 22711765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Non-invasive measurement of total respiratory compliance and resistance in cats.
    Epstein A; Godfrey S; Bar-Yishay E; Putilov A; Bark H
    Respir Physiol Neurobiol; 2007 May; 156(2):179-86. PubMed ID: 17113363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The interface between measurement and modeling of peripheral lung mechanics.
    Bates JH; Lutchen KR
    Respir Physiol Neurobiol; 2005 Aug; 148(1-2):153-64. PubMed ID: 15950552
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Guidelines for mechanical lung function measurements in psychophysiology.
    Ritz T; Dahme B; Dubois AB; Folgering H; Fritz GK; Harver A; Kotses H; Lehrer PM; Ring C; Steptoe A; Van de Woestijne KP
    Psychophysiology; 2002 Sep; 39(5):546-67. PubMed ID: 12236321
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Evaluation of respiratory function (respiratory function tests)].
    Orehek J
    Rev Mal Respir; 1998 Sep; 15 Suppl 2():S29-32. PubMed ID: 9809340
    [No Abstract]   [Full Text] [Related]  

  • 11. Clinical applications of forced oscillation technique.
    Demedts M; Van Noord JA; Van De Woestijne KP
    Chest; 1991 Apr; 99(4):795-7. PubMed ID: 2009776
    [No Abstract]   [Full Text] [Related]  

  • 12. Lung function tests in neonates and infants with chronic lung disease: lung and chest-wall mechanics.
    Gappa M; Pillow JJ; Allen J; Mayer O; Stocks J
    Pediatr Pulmonol; 2006 Apr; 41(4):291-317. PubMed ID: 16493664
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of resistive load on the phase difference between chest and mouth flow in patients with chronic obstructive pulmonary disease.
    Mishima M; Higashiya K; Kawakami K; Sugiura N; Sakai N; Hirai T; Oku Y; Chin K; Ohi M; Kuno K
    Front Med Biol Eng; 1997; 8(1):1-18. PubMed ID: 9083797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of filtering and delays on the estimates of a nonlinear respiratory mechanics model.
    Jandre FC; Carvalho AR; Pino AV; Giannella-Neto A
    Respir Physiol Neurobiol; 2005 Oct; 148(3):309-14. PubMed ID: 16143287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A recurrent parameter model to characterize the high-frequency range of respiratory impedance in healthy subjects.
    Ionescu CM; Hernandez A; De Keyser R
    IEEE Trans Biomed Circuits Syst; 2013 Dec; 7(6):882-92. PubMed ID: 24473552
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Perioperative Evaluation of Respiratory Mechanics Using the Forced Oscillation Technique.
    Kuzukawa Y; Nakahira J; Sawai T; Minami T
    Anesth Analg; 2015 Nov; 121(5):1202-6. PubMed ID: 25839180
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measuring end-expiratory lung volume and pulmonary mechanics to detect early lung function impairment in rabbits.
    Habre W; Scalfaro P; Schütz N; Stucki P; Peták F
    Respir Physiol Neurobiol; 2006 May; 152(1):72-82. PubMed ID: 16125476
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Respiratory mechanics in animals. 2. The forced oscillation technique--review].
    Reinhold P
    Berl Munch Tierarztl Wochenschr; 1997; 110(7-8):257-66. PubMed ID: 9324926
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
    Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR
    Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator.
    Cappa P; Sciuto SA; Silvestri S
    J Med Eng Technol; 2006; 30(1):31-40. PubMed ID: 16393851
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.