These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 19515440)

  • 1. Quantification of the skin sparing effect achievable with high-energy photon beams when carbon fiber tables are used.
    Mihaylov IB; Penagaricano J; Moros EG
    Radiother Oncol; 2009 Oct; 93(1):147-52. PubMed ID: 19515440
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy.
    Lee EK; Fox T; Crocker I
    Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Carbon fiber couch effects on skin dose for volumetric modulated arcs.
    Mihaylov IB; Bzdusek K; Kaus M
    Med Phys; 2011 May; 38(5):2419-23. PubMed ID: 21776776
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy.
    Mock U; Bogner J; Georg D; Auberger T; Pötter R
    Strahlenther Onkol; 2005 Jul; 181(7):448-55. PubMed ID: 15995838
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Study on surface dose generated in prostate intensity-modulated radiation therapy treatment.
    Chow JC; Grigorov GN; Barnett RB
    Med Dosim; 2006; 31(4):249-58. PubMed ID: 17134664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose escalation in the radiotherapy of non-small-cell lung cancer with aperture-based intensity modulation and photon beam energy optimization for non-preselected patients.
    St-Hilaire J; Sévigny C; Beaulieu F; Germain F; Lavoie C; Dagnault A; Gingras L; Tremblay D; Beaulieu L
    Radiother Oncol; 2009 Jun; 91(3):342-8. PubMed ID: 19135749
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer irradiation.
    Fu W; Dai J; Hu Y
    Biomed Mater Eng; 2004; 14(1):123-6. PubMed ID: 14757959
    [TBL] [Abstract][Full Text] [Related]  

  • 8. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
    Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
    Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Significant improvement in normal tissue sparing and target coverage for head and neck cancer by means of helical tomotherapy.
    Fiorino C; Dell'Oca I; Pierelli A; Broggi S; De Martin E; Di Muzio N; Longobardi B; Fazio F; Calandrino R
    Radiother Oncol; 2006 Mar; 78(3):276-82. PubMed ID: 16546279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can photon IMRT be improved by combination with mixed electron and photon techniques?
    Mu X; Olofsson L; Karlsson M; Sjögren R; Zackrisson B
    Acta Oncol; 2004; 43(8):727-35. PubMed ID: 15764217
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intensity-modulated radiotherapy for soft tissue sarcoma of the thigh.
    Hong L; Alektiar KM; Hunt M; Venkatraman E; Leibel SA
    Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):752-9. PubMed ID: 15183478
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The potential for dose dumping in normal tissues with IMRT for pelvic and H&N cancers.
    Reddy NM; Mazur AK; Sampath S; Osian A; Sood BM; Ravi A; Nori D
    Med Dosim; 2008; 33(1):55-61. PubMed ID: 18262124
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of intensity-modulated radiation therapy as a boost treatment on the lung-dose distributions for non-small-cell lung cancer.
    Choi Y; Kim JK; Lee HS; Hur WJ; Chai GY; Kang KM
    Int J Radiat Oncol Biol Phys; 2005 Nov; 63(3):683-9. PubMed ID: 15927412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rectal wall sparing by dosimetric effect of rectal balloon used during intensity-modulated radiation therapy (IMRT) for prostate cancer.
    Teh BS; Dong L; McGary JE; Mai WY; Grant W; Butler EB
    Med Dosim; 2005; 30(1):25-30. PubMed ID: 15749008
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anal wall sparing effect of an endorectal balloon in 3D conformal and intensity-modulated prostate radiotherapy.
    Smeenk RJ; van Lin EN; van Kollenburg P; Kunze-Busch M; Kaanders JH
    Radiother Oncol; 2009 Oct; 93(1):131-6. PubMed ID: 19523704
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The comparison of radiotherapy techniques for treatment of the prostate cancer: the three-field vs. the four-field.
    Milecki P; Piotrowski T; Dymnicka M
    Neoplasma; 2004; 51(1):64-9. PubMed ID: 15004663
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment-planning study of prostate cancer intensity-modulated radiotherapy with a Varian Clinac operated without a flattening filter.
    Vassiliev ON; Kry SF; Kuban DA; Salehpour M; Mohan R; Titt U
    Int J Radiat Oncol Biol Phys; 2007 Aug; 68(5):1567-71. PubMed ID: 17544596
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proton beam radiotherapy versus three-dimensional conformal stereotactic body radiotherapy in primary peripheral, early-stage non-small-cell lung carcinoma: a comparative dosimetric analysis.
    Macdonald OK; Kruse JJ; Miller JM; Garces YI; Brown PD; Miller RC; Foote RL
    Int J Radiat Oncol Biol Phys; 2009 Nov; 75(3):950-8. PubMed ID: 19801106
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparing 3DCRT and inversely optimized IMRT planning for head and neck cancer: equivalence between step-and-shoot and sliding window techniques.
    Longobardi B; De Martin E; Fiorino C; Dell'oca I; Broggi S; Cattaneo GM; Calandrino R
    Radiother Oncol; 2005 Nov; 77(2):148-56. PubMed ID: 16260056
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is intensity-modulated radiotherapy better than conventional radiation treatment and three-dimensional conformal radiotherapy for mediastinal masses in patients with Hodgkin's disease, and is there a role for beam orientation optimization and dose constraints assigned to virtual volumes?
    Girinsky T; Pichenot C; Beaudre A; Ghalibafian M; Lefkopoulos D
    Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):218-26. PubMed ID: 16169675
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.