129 related articles for article (PubMed ID: 19516945)
1. Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study.
Choo KS; Lee TH; Choi CH; Park KP; Kim CW; Kim S
J Korean Neurosurg Soc; 2009 May; 45(5):284-8. PubMed ID: 19516945
[TBL] [Abstract][Full Text] [Related]
2. Assessment of coronary arterial stents by multislice-CT angiography.
Maintz D; Grude M; Fallenberg EM; Heindel W; Fischbach R
Acta Radiol; 2003 Nov; 44(6):597-603. PubMed ID: 14616203
[TBL] [Abstract][Full Text] [Related]
3. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: comparison of a medium-smooth kernel and a sharp kernel.
Yoo WJ; Lim YS; Ahn KJ; Choi BG; Kim JY; Kim SH
Eur J Radiol; 2009 May; 70(2):362-8. PubMed ID: 18359179
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels.
Jang JH; Lim YS; Lee YJ; Yoo WJ; Sung MS; Kim BS
Acta Radiol; 2012 May; 53(4):456-60. PubMed ID: 22393160
[TBL] [Abstract][Full Text] [Related]
5. Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique.
Maintz D; Seifarth H; Flohr T; Krämer S; Wichter T; Heindel W; Fischbach R
Invest Radiol; 2003 Dec; 38(12):790-5. PubMed ID: 14627897
[TBL] [Abstract][Full Text] [Related]
6. Assessment of coronary stents by 64-slice computed tomography: in-stent lumen visibility and patency.
Kong LY; Jin ZY; Zhang SY; Zhang ZH; Wang YN; Song L; Zhang XN; Zhang YQ
Chin Med Sci J; 2009 Sep; 24(3):156-60. PubMed ID: 19848316
[TBL] [Abstract][Full Text] [Related]
7. [Assessment of coronary stent lumen visibility and patency by 64-slice spiral CT angiography].
Kong LY; Jin ZY; Wang YN; Song L; Zhang ZH; Zhang LR; Zhang SY; Lin SB; Wang Y; Zhao WM
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2006 Feb; 28(1):32-5. PubMed ID: 16548184
[TBL] [Abstract][Full Text] [Related]
8. [Assessment of coronary stent lumen visibility and patency by dual-source computed tomographic angiography].
Kong LY; Liu D; Wang YN; Song L; Zhang ZH; Jin ZY; Zhang SY; Ji B
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2010 Dec; 32(6):601-6. PubMed ID: 21219784
[TBL] [Abstract][Full Text] [Related]
9. Personalized 3D printed coronary models in coronary stenting.
Sun Z; Jansen S
Quant Imaging Med Surg; 2019 Aug; 9(8):1356-1367. PubMed ID: 31559165
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings.
Heuschmid M; Wiesinger B; Tepe G; Luz O; Kopp AF; Claussen CD; Duda SH
Eur Radiol; 2007 Jan; 17(1):265-71. PubMed ID: 16733677
[TBL] [Abstract][Full Text] [Related]
11. Thin-section multidetector CT angiography of renal artery stents.
Behar JV; Nelson RC; Zidar JP; DeLong DM; Smith TP
AJR Am J Roentgenol; 2002 May; 178(5):1155-9. PubMed ID: 11959722
[TBL] [Abstract][Full Text] [Related]
12. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.
Maintz D; Seifarth H; Raupach R; Flohr T; Rink M; Sommer T; Ozgün M; Heindel W; Fischbach R
Eur Radiol; 2006 Apr; 16(4):818-26. PubMed ID: 16333623
[TBL] [Abstract][Full Text] [Related]
13. In vivo evaluation of carotid artery stents using multi-detector-row computed tomography angiography: comparison of 3 kernels.
Lee YJ; Lim YS; Jung NY; Yoo WJ; Sung MS; Chung MH; Kim BS
J Comput Assist Tomogr; 2013; 37(3):402-7. PubMed ID: 23674012
[TBL] [Abstract][Full Text] [Related]
14. Intra-arterial DynaCT angiography: an alternative tool to assess the patency of intracranial stent lumen.
Hu J; Shi S; Xie S; Tang X; Chen K; Mu W
Clin Neurol Neurosurg; 2015 Mar; 130():105-9. PubMed ID: 25603123
[TBL] [Abstract][Full Text] [Related]
15. Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.
Hong C; Chrysant GS; Woodard PK; Bae KT
Radiology; 2004 Oct; 233(1):286-91. PubMed ID: 15304660
[TBL] [Abstract][Full Text] [Related]
16. Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents.
Gassenmaier T; Petri N; Allmendinger T; Flohr T; Maintz D; Voelker W; Bley TA
Eur Radiol; 2014 Nov; 24(11):2953-61. PubMed ID: 25038859
[TBL] [Abstract][Full Text] [Related]
17. Stent Lumen Visibility in Single-energy CT Angiography: Does Tube Potential Matter?
Boos J; Kröpil P; Lanzman RS; Aissa J; Schleich C; Antoch G; Thomas C
Acad Radiol; 2016 Jun; 23(6):752-9. PubMed ID: 27161829
[TBL] [Abstract][Full Text] [Related]
18. In Vitro Comparison of Second- and Third-generation Dual-source CT for Coronary Stent Visualization at Different Tube Potentials.
Gassenmaier T; Petri N; Allmendinger T; Flohr T; Weng AM; Kunz AS; Petritsch B; Voelker W; Bley TA
Acad Radiol; 2016 Aug; 23(8):961-8. PubMed ID: 27236611
[TBL] [Abstract][Full Text] [Related]
19. Computed tomography coronary stent imaging with iterative reconstruction: a trade-off study between medium kernel and sharp kernel.
Zhou Q; Jiang B; Dong F; Huang P; Liu H; Zhang M
J Comput Assist Tomogr; 2014; 38(4):604-12. PubMed ID: 24651753
[TBL] [Abstract][Full Text] [Related]
20. [Visualization of the intra-stent lumen in the coronary arteries and detection of restenoses with 64-slices tomography scanners with cardiac synchronization: first experience].
Larchez C; Daoud B; Ghostine S; Caussin C; Lancelin B; Paul JF
Arch Mal Coeur Vaiss; 2006 Dec; 99(12):1184-90. PubMed ID: 18942519
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]