These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

391 related articles for article (PubMed ID: 19520512)

  • 1. Bragg's Law diffraction simulations for electron backscatter diffraction analysis.
    Kacher J; Landon C; Adams BL; Fullwood D
    Ultramicroscopy; 2009 Aug; 109(9):1148-56. PubMed ID: 19520512
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-resolution elastic strain measurement from electron backscatter diffraction patterns: new levels of sensitivity.
    Wilkinson AJ; Meaden G; Dingley DJ
    Ultramicroscopy; 2006 Mar; 106(4-5):307-13. PubMed ID: 16324788
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of residual elastic strain and lattice rotations with high resolution electron backscatter diffraction.
    Britton TB; Wilkinson AJ
    Ultramicroscopy; 2011 Jul; 111(8):1395-404. PubMed ID: 21864783
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reply to comment by Maurice et al. in response to "Bragg's Law Diffraction Simulations for Electron Backscatter Diffraction Analysis".
    Kacher J; Basinger J; Adams BL; Fullwood DT
    Ultramicroscopy; 2010 Jun; 110(7):741-3. PubMed ID: 20189305
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comments on the paper "Bragg's law diffraction simulations for electron backscatter diffraction analysis" by Josh Kacher, Colin Landon, Brent L. Adams & David Fullwood.
    Maurice C; Fortunier R; Driver J; Day A; Mingard K; Meaden G
    Ultramicroscopy; 2010 Jun; 110(7):761-2. PubMed ID: 20223590
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High resolution electron backscatter diffraction measurements of elastic strain variations in the presence of larger lattice rotations.
    Britton TB; Wilkinson AJ
    Ultramicroscopy; 2012 Mar; 114():82-95. PubMed ID: 22366635
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy assessment of elastic strain measurement by EBSD.
    Villert S; Maurice C; Wyon C; Fortunier R
    J Microsc; 2009 Feb; 233(2):290-301. PubMed ID: 19220695
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Factors affecting the accuracy of high resolution electron backscatter diffraction when using simulated patterns.
    Britton TB; Maurice C; Fortunier R; Driver JH; Day AP; Meaden G; Dingley DJ; Mingard K; Wilkinson AJ
    Ultramicroscopy; 2010 Nov; 110(12):1443-53. PubMed ID: 20888125
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Elastic strain tensor measurement using electron backscatter diffraction in the SEM.
    Dingley DJ; Wilkinson AJ; Meaden G; Karamched PS
    J Electron Microsc (Tokyo); 2010 Aug; 59 Suppl 1():S155-63. PubMed ID: 20634548
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The significance of Bragg's law in electron diffraction and microscopy, and Bragg's second law.
    Humphreys CJ
    Acta Crystallogr A; 2013 Jan; 69(Pt 1):45-50. PubMed ID: 23250060
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessing the precision of strain measurements using electron backscatter diffraction--part 1: detector assessment.
    Britton TB; Jiang J; Clough R; Tarleton E; Kirkland AI; Wilkinson AJ
    Ultramicroscopy; 2013 Dec; 135():126-35. PubMed ID: 24018163
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of pattern overlap on the accuracy of high resolution electron backscatter diffraction measurements.
    Tong V; Jiang J; Wilkinson AJ; Britton TB
    Ultramicroscopy; 2015 Aug; 155():62-73. PubMed ID: 25957534
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A 3D Hough transform for indexing EBSD and Kossel patterns.
    Maurice C; Fortunier R
    J Microsc; 2008 Jun; 230(Pt 3):520-9. PubMed ID: 18503678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of Dynamically Simulated Reference Patterns for Cross-Correlation Electron Backscatter Diffraction.
    Jackson BE; Christensen JJ; Singh S; De Graef M; Fullwood DT; Homer ER; Wagoner RH
    Microsc Microanal; 2016 Aug; 22(4):789-802. PubMed ID: 27509538
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limits of simulation based high resolution EBSD.
    Alkorta J
    Ultramicroscopy; 2013 Aug; 131():33-8. PubMed ID: 23676453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The characterization of low-angle boundaries by EBSD.
    Bate PS; Knutsen RD; Brough I; Humphreys FJ
    J Microsc; 2005 Oct; 220(Pt 1):36-46. PubMed ID: 16269062
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Line-rotated remapping for high-resolution electron backscatter diffraction.
    Wang Y; Brodusch N; Gauvin R; Zeng Y
    Ultramicroscopy; 2022 Dec; 242():113623. PubMed ID: 36150291
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Orientation precision of electron backscatter diffraction measurements near grain boundaries.
    Wright SI; Nowell MM; de Kloe R; Chan L
    Microsc Microanal; 2014 Jun; 20(3):852-63. PubMed ID: 24576405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Phase determination in dual phase steels via HREBSD-based tetragonality mapping.
    Adams D; Miles MP; Homer ER; Brown T; Mishra RK; Fullwood DT
    J Microsc; 2021 Apr; 282(1):60-72. PubMed ID: 33226120
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A transmission electron microscope (TEM) calibration standard sample for all magnification, camera constant, and image/diffraction pattern rotation calibrations.
    McCaffrey JP; Baribeau JM
    Microsc Res Tech; 1995 Dec; 32(5):449-54. PubMed ID: 8563043
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.