680 related articles for article (PubMed ID: 19521002)
1. Efficient Monte Carlo simulation of multileaf collimators using geometry-related variance-reduction techniques.
Brualla L; Salvat F; Palanco-Zamora R
Phys Med Biol; 2009 Jul; 54(13):4131-49. PubMed ID: 19521002
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric verification of a Monte Carlo electron beam model for an add-on eMLC.
Vatanen T; Traneus E; Lahtinen T
Phys Med Biol; 2008 Jan; 53(2):391-404. PubMed ID: 18184994
[TBL] [Abstract][Full Text] [Related]
3. Benchmark of penelope for low and medium energy X-rays.
Chica U; Anguiano M; Lallena AM
Phys Med; 2009 Jun; 25(2):51-7. PubMed ID: 18495512
[TBL] [Abstract][Full Text] [Related]
4. PRIMO: a graphical environment for the Monte Carlo simulation of Varian and Elekta linacs.
Rodriguez M; Sempau J; Brualla L
Strahlenther Onkol; 2013 Oct; 189(10):881-6. PubMed ID: 24005581
[TBL] [Abstract][Full Text] [Related]
5. Experimental validation of a Monte Carlo proton therapy nozzle model incorporating magnetically steered protons.
Peterson SW; Polf J; Bues M; Ciangaru G; Archambault L; Beddar S; Smith A
Phys Med Biol; 2009 May; 54(10):3217-29. PubMed ID: 19420426
[TBL] [Abstract][Full Text] [Related]
6. Backscattered radiation into a transmission ionization chamber: measurement and Monte Carlo simulation.
Yoshizumi MT; Yoriyaz H; Caldas LV
Appl Radiat Isot; 2010; 68(4-5):586-8. PubMed ID: 19884019
[TBL] [Abstract][Full Text] [Related]
7. Investigation of an efficient source design for Cobalt-60-based tomotherapy using EGSnrc Monte Carlo simulations.
Joshi CP; Darko J; Vidyasagar PB; Schreiner LJ
Phys Med Biol; 2008 Feb; 53(3):575-92. PubMed ID: 18199903
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of the dynamic micro-multileaf collimator of a LINAC Elekta Precise using PENELOPE.
González W; Lallena AM; Alfonso R
Phys Med Biol; 2011 Jun; 56(11):3417-31. PubMed ID: 21572185
[TBL] [Abstract][Full Text] [Related]
9. Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of conjunctival lymphoma.
Brualla L; Palanco-Zamora R; Wittig A; Sempau J; Sauerwein W
Phys Med Biol; 2009 Sep; 54(18):5469-81. PubMed ID: 19706962
[TBL] [Abstract][Full Text] [Related]
10. Study on the tongue and groove effect of the Elekta multileaf collimator using Monte Carlo simulation and film dosimetry.
Haryanto F; Fippel M; Bakai A; Nüsslin F
Strahlenther Onkol; 2004 Jan; 180(1):57-61. PubMed ID: 14704846
[TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans.
Pisaturo O; Moeckli R; Mirimanoff RO; Bochud FO
Phys Med Biol; 2009 Jul; 54(13):4299-310. PubMed ID: 19531844
[TBL] [Abstract][Full Text] [Related]
12. PENLINAC: extending the capabilities of the Monte Carlo code PENELOPE for the simulation of therapeutic beams.
Rodríguez ML
Phys Med Biol; 2008 Sep; 53(17):4573-93. PubMed ID: 18678929
[TBL] [Abstract][Full Text] [Related]
13. Azimuthal particle redistribution for the reduction of latent phase-space variance in Monte Carlo simulations.
Bush K; Zavgorodni SF; Beckham WA
Phys Med Biol; 2007 Jul; 52(14):4345-60. PubMed ID: 17664612
[TBL] [Abstract][Full Text] [Related]
14. Application of voxel phantoms and Monte Carlo method to whole-body counter calibration.
Kinase S; Takagi S; Noguchi H; Saito K
Radiat Prot Dosimetry; 2007; 125(1-4):189-93. PubMed ID: 17522042
[TBL] [Abstract][Full Text] [Related]
15. Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations.
Tacke MB; Szymanowski H; Oelfke U; Schulze C; Nuss S; Wehrwein E; Leidenberger S
Med Phys; 2006 Apr; 33(4):1125-32. PubMed ID: 16696490
[TBL] [Abstract][Full Text] [Related]
16. A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields.
Sempau J; Badal A; Brualla L
Med Phys; 2011 Nov; 38(11):5887-95. PubMed ID: 22047353
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulation using the PENELOPE code with an ant colony algorithm to study MOSFET detectors.
Carvajal MA; García-Pareja S; Guirado D; Vilches M; Anguiano M; Palma AJ; Lallena AM
Phys Med Biol; 2009 Oct; 54(20):6263-76. PubMed ID: 19794247
[TBL] [Abstract][Full Text] [Related]
18. Spatial dependence of MLC transmission in IMRT delivery.
Lorenz F; Nalichowski A; Rosca F; Kung J; Wenz F; Zygmanski P
Phys Med Biol; 2007 Oct; 52(19):5985-99. PubMed ID: 17881814
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo Modeling and Commissioning of a Dual-layer Micro Multileaf Collimator.
Giantsoudi D; Stathakis S; Liu Y; Shi C; Papanikolaou N
Technol Cancer Res Treat; 2009 Apr; 8(2):105-14. PubMed ID: 19334791
[TBL] [Abstract][Full Text] [Related]
20. Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: simplified estimates with PENELOPE Monte Carlo models.
Baumgartner A; Steurer A; Maringer FJ
Appl Radiat Isot; 2009 Nov; 67(11):2007-12. PubMed ID: 19692253
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]