These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
59 related articles for article (PubMed ID: 1953164)
1. [Experimental estimation of the effect of antibiotics, immobilized on the surface of titanium implant, on the development of the inflammatory process]. Samedov TI; Araviĭskaia DD; Tikhonova LS; Guliev BG; Makarov KA Antibiot Khimioter; 1991 May; 36(5):16-8. PubMed ID: 1953164 [TBL] [Abstract][Full Text] [Related]
2. [Immobilization of antibiotics on a titanium surface]. Tikhonova LS; Samedov TI; Galkin VIu; Babkov VV; Makarov KA; Efimov AG Antibiot Khimioter; 1990 Jan; 35(1):27-30. PubMed ID: 2185708 [TBL] [Abstract][Full Text] [Related]
3. Fibrous capsule formation around titanium and copper. Suska F; Emanuelsson L; Johansson A; Tengvall P; Thomsen P J Biomed Mater Res A; 2008 Jun; 85(4):888-96. PubMed ID: 17896778 [TBL] [Abstract][Full Text] [Related]
4. Difference in tissue response to nitrogen-ion-implanted titanium and c.p. titanium in the abdominal wall of the rat. Röstlund T; Thomsen P; Bjursten LM; Ericson LE J Biomed Mater Res; 1990 Jul; 24(7):847-60. PubMed ID: 2144531 [TBL] [Abstract][Full Text] [Related]
5. A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium-coated percutaneous implants. Chehroudi B; Gould TR; Brunette DM J Biomed Mater Res; 1991 Mar; 25(3):387-405. PubMed ID: 2026643 [TBL] [Abstract][Full Text] [Related]
6. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. Thomas KA; Kay JF; Cook SD; Jarcho M J Biomed Mater Res; 1987 Dec; 21(12):1395-414. PubMed ID: 3429474 [TBL] [Abstract][Full Text] [Related]
7. Early inflammatory response in soft tissues induced by thin calcium phosphates. Rydén L; Molnar D; Esposito M; Johansson A; Suska F; Palmquist A; Thomsen P J Biomed Mater Res A; 2013 Sep; 101(9):2712-7. PubMed ID: 23463679 [TBL] [Abstract][Full Text] [Related]
9. Peri-implant reactivity and osteoinductive potential of immobilized rhBMP-2 on titanium carriers. Chatzinikolaidou M; Lichtinger TK; Müller RT; Jennissen HP Acta Biomater; 2010 Nov; 6(11):4405-21. PubMed ID: 20558328 [TBL] [Abstract][Full Text] [Related]
10. Histologic comparison of ceramic and titanium implants in cats. Barth E; Johansson C; Albrektsson T Int J Oral Maxillofac Implants; 1990; 5(3):227-31. PubMed ID: 2098326 [TBL] [Abstract][Full Text] [Related]
11. Cell and matrix reactions at titanium implants in surgically prepared rat tibiae. Masuda T; Salvi GE; Offenbacher S; Felton DA; Cooper LF Int J Oral Maxillofac Implants; 1997; 12(4):472-85. PubMed ID: 9274076 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of the soft tissue interface at titanium implants with different surface treatments: experimental study on rabbits. Ungersböck A; Pohler O; Perren SM Biomed Mater Eng; 1994; 4(4):317-25. PubMed ID: 7950879 [TBL] [Abstract][Full Text] [Related]
13. The bisphosphonate pamidronate on the surface of titanium stimulates bone formation around tibial implants in rats. Kajiwara H; Yamaza T; Yoshinari M; Goto T; Iyama S; Atsuta I; Kido MA; Tanaka T Biomaterials; 2005 Feb; 26(6):581-7. PubMed ID: 15282136 [TBL] [Abstract][Full Text] [Related]
14. [The question of the transmissibility of the results of subcutaneous tests of biomaterials from animals to humans]. Schreiber H; Keller F; Kinzl HP; Hunger H; Knöfler W; Rübling U; Merten W Z Exp Chir Transplant Kunstliche Organe; 1990; 23(1):23-5. PubMed ID: 2219998 [TBL] [Abstract][Full Text] [Related]
15. Titanium-coated micromachined grooves of different dimensions affect epithelial and connective-tissue cells differently in vivo. Chehroudi B; Gould TR; Brunette DM J Biomed Mater Res; 1990 Sep; 24(9):1203-19. PubMed ID: 2211745 [TBL] [Abstract][Full Text] [Related]
16. A one stage versus two stage surgical technique. Tissue reaction to a percutaneous device provided with titanium fiber mesh applicable for peritoneal dialysis. Paquay YC; De Ruijter AE; van der Waerden JP; Jansen JA ASAIO J; 1996; 42(6):961-7. PubMed ID: 8959270 [TBL] [Abstract][Full Text] [Related]
18. Effects of a grooved titanium-coated implant surface on epithelial cell behavior in vitro and in vivo. Chehroudi B; Gould TR; Brunette DM J Biomed Mater Res; 1989 Sep; 23(9):1067-85. PubMed ID: 2777834 [TBL] [Abstract][Full Text] [Related]
19. Histomorphometric analysis of the repair of a segmental diaphyseal defect with ceramic and titanium fibermetal implants: effects of bone marrow. Wolff D; Goldberg VM; Stevenson S J Orthop Res; 1994 May; 12(3):439-46. PubMed ID: 8207598 [TBL] [Abstract][Full Text] [Related]
20. Enhanced osteoconductivity of titanium implant by polarization-induced surface charges. Nozaki K; Wang W; Horiuchi N; Nakamura M; Takakuda K; Yamashita K; Nagai A J Biomed Mater Res A; 2014 Sep; 102(9):3077-86. PubMed ID: 24123807 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]