These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 1953499)

  • 21. An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements.
    Apipunyasopon L; Srisatit S; Phaisangittisakul N
    J Radiat Res; 2013 Mar; 54(2):374-82. PubMed ID: 23104898
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code.
    Mahur M; Singh M; Gurjar OP; Semwal MK
    J Biomed Phys Eng; 2022 Oct; 12(5):455-464. PubMed ID: 36313413
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Surface dose measurements with GafChromic EBT film for 6 and 18MV photon beams.
    Bilge H; Cakir A; Okutan M; Acar H
    Phys Med; 2009 Jun; 25(2):101-4. PubMed ID: 18571964
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dependences of mucosal dose on photon beams in head-and-neck intensity-modulated radiation therapy: a Monte Carlo study.
    Chow JC; Owrangi AM
    Med Dosim; 2012; 37(2):195-200. PubMed ID: 21993201
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dual scattering foil design for poly-energetic electron beams.
    Kainz KK; Antolak JA; Almond PR; Bloch CD; Hogstrom KR
    Phys Med Biol; 2005 Mar; 50(5):755-67. PubMed ID: 15798252
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation.
    Chow JC; Grigorov GN
    Phys Med Biol; 2007 Jul; 52(13):3965-77. PubMed ID: 17664588
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.
    Mesbahi A
    Appl Radiat Isot; 2007 Sep; 65(9):1029-36. PubMed ID: 17616465
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of immobilization beds on the dose in the entrance and exit dose region for Co-60, 4, 6 and 15 MV photons.
    Bilge H; Yondem S; Kucucuk H; Cakir A; Meral R
    J BUON; 2008; 13(3):385-90. PubMed ID: 18979554
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electron contamination in clinical high energy photon beams.
    Sjögren R; Karlsson M
    Med Phys; 1996 Nov; 23(11):1873-81. PubMed ID: 8947901
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Skin dose from radiotherapy X-ray beams: the influence of energy.
    Butson MJ; Mathur JN; Metcalfe PE
    Australas Radiol; 1997 May; 41(2):148-50. PubMed ID: 9153811
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Investigation on the reduction of electron contamination with a 6-MV x-ray beam.
    Parthasaradhi K; Prasad SG; Rao BM; Lee Y; Ruparel R; Garces R
    Med Phys; 1989; 16(1):123-5. PubMed ID: 2493564
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Sources of electron contamination for the Clinac-35 25-MV photon beam.
    Petti PL; Goodman MS; Sisterson JM; Biggs PJ; Gabriel TA; Mohan R
    Med Phys; 1983; 10(6):856-61. PubMed ID: 6419032
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A measurement and analysis of buildup region dose for open field photon beams (cobalt-60 through 24 MV).
    McCullough EC
    Med Dosim; 1994; 19(1):5-14. PubMed ID: 8003208
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Improving the buildup and depth-dose characteristics of high energy photon beams by using electron filters.
    Ling CC; Biggs PJ
    Med Phys; 1979; 6(4):296-301. PubMed ID: 113657
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Characteristics of secondary electrons produced by 6, 10 and 24 MV x-ray beams.
    Jursinic PA; Mackie TR
    Phys Med Biol; 1996 Aug; 41(8):1499-509. PubMed ID: 8858733
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Magnetic fields with photon beams: Monte Carlo calculations for a model magnetic field.
    Jette D
    Med Phys; 2000 Dec; 27(12):2726-38. PubMed ID: 11190956
    [TBL] [Abstract][Full Text] [Related]  

  • 38. SU-E-T-143: Effect of Physical and Virtual Wedges on the Surface Dose at Various SSD for 6 and 15 MV Photon Beam.
    Yadav G; Sinha SN; Ashokkumar S; Raman K; Mishra M; Thiyagarajan R; Yadav RS
    Med Phys; 2012 Jun; 39(6Part11):3736. PubMed ID: 28517136
    [TBL] [Abstract][Full Text] [Related]  

  • 39. X-ray surface dose measurements using TLD extrapolation.
    Kron T; Elliot A; Wong T; Showell G; Clubb B; Metcalfe P
    Med Phys; 1993; 20(3):703-11. PubMed ID: 8350822
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Contaminant electrons in the build-up region of a 4 MV photon beam.
    Rustgi SN; Gromadzki ZC; Ling CC; Yorke ED
    Phys Med Biol; 1983 Jun; 28(6):659-65. PubMed ID: 6410419
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.