BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 19535700)

  • 41. Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation.
    Kim YK; Shin WJ; Song JG; Jun IG; Kim HY; Seong SH; Hwang GS
    Transplant Proc; 2009 Dec; 41(10):4220-8. PubMed ID: 20005373
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Thermodilution vs transesophageal echocardiography for cardiac output measurement in patients with good left ventricle function].
    Bródka J; Tułecki Ł; Ciurysek M; Gburek T
    Anestezjol Intens Ter; 2010; 42(1):15-8. PubMed ID: 20608209
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Laparoscopic colon surgery: unreliability of end-tidal CO2 monitoring.
    Klopfenstein CE; Schiffer E; Pastor CM; Beaussier M; Francis K; Soravia C; Herrmann FR
    Acta Anaesthesiol Scand; 2008 May; 52(5):700-7. PubMed ID: 18419725
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass.
    Lorsomradee S; Lorsomradee SR; Cromheecke S; De Hert SG
    Anaesthesia; 2007 Oct; 62(10):979-83. PubMed ID: 17845647
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Disagreement between fourth generation FloTrac and LiDCOrapid measurements of cardiac output and stroke volume variation during laparoscopic colectomy.
    Nakasuji M; Okutani A; Miyata T; Imanaka N; Tanaka M; Nakasuji K; Nagai M
    J Clin Anesth; 2016 Dec; 35():150-156. PubMed ID: 27871513
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effect of xenon anaesthesia on accuracy of cardiac output measurement using partial CO2 rebreathing.
    Bein B; Hanne P; Hanss R; Renner J; Weber B; Steinfath M; Scholz J; Tonner PH
    Anaesthesia; 2004 Nov; 59(11):1104-10. PubMed ID: 15479320
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery.
    Mehta Y; Chand RK; Sawhney R; Bhise M; Singh A; Trehan N
    J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):394-9. PubMed ID: 18503927
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Measurement of cardiac output by transpulmonary arterial thermodilution using a long radial artery catheter. A comparison with intermittent pulmonary artery thermodilution.
    Orme RM; Pigott DW; Mihm FG
    Anaesthesia; 2004 Jun; 59(6):590-4. PubMed ID: 15144300
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.
    Della Rocca G; Costa MG; Chiarandini P; Bertossi G; Lugano M; Pompei L; Coccia C; Sainz-Barriga M; Pietropaoli P
    J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution.
    Estagnasié P; Djedaini K; Mier L; Coste F; Dreyfuss D
    Intensive Care Med; 1997 Jul; 23(7):753-9. PubMed ID: 9290989
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution.
    Broch O; Bein B; Gruenewald M; Masing S; Huenges K; Haneya A; Steinfath M; Renner J
    Biomed Res Int; 2016; 2016():3468015. PubMed ID: 28116294
    [No Abstract]   [Full Text] [Related]  

  • 52. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler.
    Chen G; Meng L; Alexander B; Tran NP; Kain ZN; Cannesson M
    J Clin Anesth; 2012 Jun; 24(4):275-83. PubMed ID: 22608581
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Cardiac output by arterial pulse contour: reliability under hemodynamic derangements.
    Romagnoli S; Romano SM; Bevilacqua S; Ciappi F; Lazzeri C; Peris A; Dini D; Gelsomino S
    Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):642-6. PubMed ID: 19299422
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Is arterial pulse contour analysis using Nexfin a new option in the noninvasive measurement of cardiac output?--A pilot study.
    Trinkmann F; Sampels M; Doesch C; Papavassiliu T; Brade J; Schmid-Bindert G; Hoffmann U; Borggrefe M; Kaden JJ; Saur J
    J Cardiothorac Vasc Anesth; 2013 Apr; 27(2):283-7. PubMed ID: 23063946
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Clinical usefulness of continuous cardiac output measurement: PulseCO].
    Yamagishi A; Kunisawa T; Nagashima M; Takahata O; Iwasaki H
    Masui; 2009 Apr; 58(4):422-5. PubMed ID: 19364001
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique.
    Mantovani MM; Fantoni DT; Gimenes AM; de Castro JR; Flor PB; Ida KK; Schwartz DS
    BMC Vet Res; 2017 Nov; 13(1):325. PubMed ID: 29121915
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Pulse contour-derived cardiac output in hemodialysis patients.
    Cordtz J; Ladefoged SD
    Hemodial Int; 2010 Jan; 14(1):78-83. PubMed ID: 20377651
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo-derived cardiac output measurements: a prospective comparison study.
    Eleftheriadis S; Galatoudis Z; Didilis V; Bougioukas I; Schön J; Heinze H; Berger KU; Heringlake M
    Crit Care; 2009; 13(6):R179. PubMed ID: 19900267
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery - a prospective observational study.
    Lorenzen U; Pohlmann M; Hansen J; Klose P; Gruenewald M; Renner J; Elke G
    BMC Anesthesiol; 2020 Aug; 20(1):196. PubMed ID: 32778047
    [TBL] [Abstract][Full Text] [Related]  

  • 60. The effect of anaesthesia and aortic clamping on cardiac output measurement using arterial pulse power analysis during aortic aneurysm repair.
    Beattie C; Moores C; Thomson AJ; Nimmo AF
    Anaesthesia; 2010 Dec; 65(12):1194-9. PubMed ID: 21182600
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.