These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 19536626)

  • 1. Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.
    Lee H; Ikeuchi Y; Akagawa E; Tatsumi E; Taenaka Y; Yamamoto T
    J Artif Organs; 2009; 12(2):98-104. PubMed ID: 19536626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental study on the Reynolds and viscous shear stress of bileaflet mechanical heart valves in a pneumatic ventricular assist device.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2009; 55(4):348-54. PubMed ID: 19521236
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow visualization of a monoleaflet and bileaflet mechanical heart valve in a pneumatic ventricular assist device using a PIV system.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2010; 56(3):186-93. PubMed ID: 20449894
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity.
    Lee H; Homma A; Taenaka Y
    Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.
    Akutsu T; Saito J
    J Artif Organs; 2006; 9(3):165-78. PubMed ID: 16998702
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position.
    Feng Z; Umezu M; Fujimoto T; Tsukahara T; Nurishi M; Kawaguchi D
    Artif Organs; 2000 May; 24(5):346-54. PubMed ID: 10848675
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart.
    Lee H; Tatsumi E; Homma A; Tsukiya T; Taenaka Y
    J Artif Organs; 2006; 9(3):154-60. PubMed ID: 16998700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Application of Bileaflet Mechanical Heart Valves in the Polish Ventricular Assist Device: Physical and Numerical Study and First Clinical Usage.
    Malota Z; Sadowski W; Krzyskow M; Stolarzewicz B
    Artif Organs; 2016 Mar; 40(3):252-60. PubMed ID: 26365391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemodynamic performance of four mechanical bileaflet prosthetic valves in the mitral position: an echocardiographic study.
    Reisner SA; Harpaz D; Skulski R; Borenstein D; Milo S; Meltzer RS
    Eur J Ultrasound; 1998 Dec; 8(3):193-200. PubMed ID: 9971902
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.
    Akutsu T; Saito J; Imai R; Suzuki T; Cao XD
    J Artif Organs; 2008; 11(2):75-90. PubMed ID: 18604612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mitral and mitro-aortic valve replacement with Sorin Bicarbon valves compared with St. Jude Medical valves.
    Camilleri LF; Bailly P; Legault BJ; Miguel B; D'Agrosa-Boiteux MC; de Riberolles CM
    Cardiovasc Surg; 2001 Jun; 9(3):272-80. PubMed ID: 11336851
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of the bileaflet inlet valve angle on the flow of a pediatric ventricular assist device: Experimental analysis.
    Lemos BLHD; Bortolin VAA; Amaral RL; Mazzetto M; Cestari IA; Meneghini JR
    Artif Organs; 2022 Sep; 46(9):1833-1846. PubMed ID: 35524699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of the driving condition of a pneumatic ventricular assist device on the cavitation intensity of the inlet and outlet mechanical heart valves.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2009; 55(4):328-34. PubMed ID: 19506466
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.
    Akagawa E; Lee H; Tatsumi E; Homma A; Tsukiya T; Katagiri N; Kakuta Y; Nishinaka T; Mizuno T; Ota K; Kansaku R; Taenaka Y
    J Artif Organs; 2007; 10(2):85-91. PubMed ID: 17574510
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves.
    Grigioni M; Daniele C; D'Avenio G; Barbaro V
    J Biomech; 2001 May; 34(5):613-21. PubMed ID: 11311702
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical].
    Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A
    G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrodynamic characteristics of the Edwards MIRA bileaflet valve in a pneumatic ventricular assist device.
    Lee H; Taenaka Y
    ASAIO J; 2007; 53(4):397-402. PubMed ID: 17667221
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.