BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 19536848)

  • 1. Hemoglobin lansing: a novel hemoglobin variant causing falsely decreased oxygen saturation by pulse oximetry.
    Sarikonda KV; Ribeiro RS; Herrick JL; Hoyer JD
    Am J Hematol; 2009 Aug; 84(8):541. PubMed ID: 19536848
    [No Abstract]   [Full Text] [Related]  

  • 2. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge.
    Hladik A; Lynshue K
    J Pediatr Hematol Oncol; 2008 Nov; 30(11):850-2. PubMed ID: 18989162
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Unexpected falsely low pulse oximeter measurements in a child with hemoglobin Cheverly.
    Yodfat UA; Vaida SJ
    Anesth Analg; 2006 Jul; 103(1):259-60. PubMed ID: 16790675
    [No Abstract]   [Full Text] [Related]  

  • 4. A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry.
    Zur B; Hornung A; Breuer J; Doll U; Bernhardt C; Ludwig M; Stoffel-Wagner B
    Clin Chem; 2008 Mar; 54(3):594-6. PubMed ID: 18310146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. First reported case of hemoglobin lansing in Asia detected by false low oxygen saturation on pulse oximetry.
    Ishitsuka K; Uchino J; Kato J; Ikuta M; Watanabe K; Matsunaga A; Tamura K
    Int J Hematol; 2012 Jun; 95(6):731-2. PubMed ID: 22639049
    [No Abstract]   [Full Text] [Related]  

  • 6. Unexpected falsely low pulse oximeter measurements in a child with hemoglobin Southampton.
    Costandi AJ; Mahmoud M
    J Clin Anesth; 2016 Sep; 33():320-1. PubMed ID: 27555186
    [No Abstract]   [Full Text] [Related]  

  • 7. Low oxygen saturation and severe anemia in compound heterozygous Hb Louisville [β42(CD1)Phe→Leu] and Hb La Desirade [β129(H7)Ala→Val].
    Kamseng P; Trakulsrichai S; Trachoo O; Yimniam W; Panthan B; Jittorntam P; Niparuck P; Sanguanwit P; Wananukul W; Jindadamrongwech S
    Hematology; 2017 Mar; 22(2):114-118. PubMed ID: 27670359
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Oxygen saturation in pulse oximetry in hemoglobin anomalies.
    Zur B; Bagci S; Ludwig M; Stoffel-Wagner B
    Klin Padiatr; 2012 Jul; 224(4):259-65. PubMed ID: 22815129
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neonatal cyanosis from a hemoglobin variant.
    Ostrander RJ; Green NS
    N Engl J Med; 2011 Jul; 365(4):378. PubMed ID: 21793761
    [No Abstract]   [Full Text] [Related]  

  • 10. Case-control studies of novel hemoglobin anomalies as differential diagnosis in sleep apnea syndrome.
    Zur B; Ludwig M; Stoffel-Wagner B
    Sleep Breath; 2013 May; 17(2):557-63. PubMed ID: 22581484
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Decreased oxygen saturation as a result of haemoglobin Titusville.
    Avellan-Hietanen H; Aittomaki J; Ekroos H; Aittomäki K; Turpeinen U; Kalkkinen N; Sovijärvi A
    Clin Respir J; 2008 Oct; 2(4):242-4. PubMed ID: 20298341
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemoglobin Denver, a cause of desaturated pulse oximetry. A pediatric case report.
    Rossetti E; Eandi Eberle S; Aguirre F; Pepe C; Díaz L; Harris V; Ávalos V
    Arch Argent Pediatr; 2023 Oct; 121(5):e202202801. PubMed ID: 36857142
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemoglobin Titusville, a low oxygen affinity variant hemoglobin, in a family of Northern European background.
    Luo HY; Irving I; Prior J; Lim E; Eung SH; Skelton TP; Erber WN; Steinberg MH; Chui DH
    Am J Hematol; 2004 Dec; 77(4):384-6. PubMed ID: 15551405
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemoglobinopathy case finding by pulse oximetry.
    Bruns CM; Thet LA; Woodson RD; Schultz J; Hla KM
    Am J Hematol; 2003 Oct; 74(2):142-3. PubMed ID: 14508804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulse oximetry in mixed haemoglobinopathy.
    Corkeron MA; Pavy TJ
    Anaesth Intensive Care; 1996 Oct; 24(5):619-20. PubMed ID: 8909685
    [No Abstract]   [Full Text] [Related]  

  • 16. Diagnosis and clinical presentation of hemoglobin Kirksey.
    Hitaka D; Arai J
    Pediatr Int; 2016 Mar; 58(3):235-237. PubMed ID: 26678362
    [TBL] [Abstract][Full Text] [Related]  

  • 17. First Family Case of Hemoglobinopathy Titusville in China with Falsely Low SpO2 and Unmeasurable SaO2.
    Chen YX; He JJ; Yu YY; Dai W; Zhang G
    Clin Lab; 2024 Mar; 70(3):. PubMed ID: 38469764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemoglobin köln and pregnancy.
    Cheung VYT; Silverman JA
    J Obstet Gynaecol Can; 2008 Oct; 30(10):907-909. PubMed ID: 19038075
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low oxygen saturation by pulse oximetry may be associated with a low oxygen affinity hemoglobin variant, hemoglobin Titusville.
    Deyell R; Jackson S; Spier S; Le D; Poon MC
    J Pediatr Hematol Oncol; 2006 Feb; 28(2):100-2. PubMed ID: 16462584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new beta-chain variant: Hb stockholm [beta 7(A4)GluAsp] causes falsely low Hb A(1c).
    Bergman AC; Beshara S; Byman I; Karim R; Landin B
    Hemoglobin; 2009; 33(2):137-42. PubMed ID: 19373590
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.