146 related articles for article (PubMed ID: 19544902)
1. Assessing the performance of biological filtration as pretreatment to low pressure membranes for drinking water.
Hallé C; Huck PM; Peldszus S; Haberkamp J; Jekel M
Environ Sci Technol; 2009 May; 43(10):3878-84. PubMed ID: 19544902
[TBL] [Abstract][Full Text] [Related]
2. Reversible and irreversible low-pressure membrane foulants in drinking water treatment: Identification by principal component analysis of fluorescence EEM and mitigation by biofiltration pretreatment.
Peldszus S; Hallé C; Peiris RH; Hamouda M; Jin X; Legge RL; Budman H; Moresoli C; Huck PM
Water Res; 2011 Oct; 45(16):5161-70. PubMed ID: 21835423
[TBL] [Abstract][Full Text] [Related]
3. Assessing the role of feed water constituents in irreversible membrane fouling of pilot-scale ultrafiltration drinking water treatment systems.
Peiris RH; Jaklewicz M; Budman H; Legge RL; Moresoli C
Water Res; 2013 Jun; 47(10):3364-74. PubMed ID: 23615336
[TBL] [Abstract][Full Text] [Related]
4. Pilot-scale investigation of drinking water ultrafiltration membrane fouling rates using advanced data analysis techniques.
Chen F; Peldszus S; Peiris RH; Ruhl AS; Mehrez R; Jekel M; Legge RL; Huck PM
Water Res; 2014 Jan; 48():508-18. PubMed ID: 24188578
[TBL] [Abstract][Full Text] [Related]
5. Membrane fouling in ultrafiltration of natural water after pretreatment to different extents.
Ao L; Liu W; Zhao L; Wang X
J Environ Sci (China); 2016 May; 43():234-243. PubMed ID: 27155429
[TBL] [Abstract][Full Text] [Related]
6. Hydrophilic fraction of natural organic matter causing irreversible fouling of microfiltration and ultrafiltration membranes.
Yamamura H; Okimoto K; Kimura K; Watanabe Y
Water Res; 2014 May; 54():123-36. PubMed ID: 24565803
[TBL] [Abstract][Full Text] [Related]
7. Effect of hydraulically reversible and hydraulically irreversible fouling on the removal of MS2 and φX174 bacteriophage by an ultrafiltration membrane.
ElHadidy AM; Peldszus S; Van Dyke MI
Water Res; 2014 Sep; 61():297-307. PubMed ID: 24967952
[TBL] [Abstract][Full Text] [Related]
8. Further insight into the roles of the chemical composition of dissolved organic matter (DOM) on ultrafiltration membranes as revealed by multiple advanced DOM characterization tools.
Ly QV; Hur J
Chemosphere; 2018 Jun; 201():168-177. PubMed ID: 29524817
[TBL] [Abstract][Full Text] [Related]
9. Effect of ozone on biopolymers in biofiltration and ultrafiltration processes.
Siembida-Lösch B; Anderson WB; Wang YM; Bonsteel J; Huck PM
Water Res; 2015 Mar; 70():224-34. PubMed ID: 25540836
[TBL] [Abstract][Full Text] [Related]
10. Modeling the improvement of ultrafiltration membrane mass transfer when using biofiltration pretreatment in surface water applications.
Netcher AC; Duranceau SJ
Water Res; 2016 Mar; 90():258-264. PubMed ID: 26745174
[TBL] [Abstract][Full Text] [Related]
11. Irreversible membrane fouling during ultrafiltration of surface water.
Kimura K; Hane Y; Watanabe Y; Amy G; Ohkuma N
Water Res; 2004; 38(14-15):3431-41. PubMed ID: 15276760
[TBL] [Abstract][Full Text] [Related]
12. Tracking inorganic foulants irreversibly accumulated on low-pressure membranes for treating surface water.
Yamamura H; Kimura K; Higuchi K; Watanabe Y; Ding Q; Hafuka A
Water Res; 2015 Dec; 87():218-24. PubMed ID: 26414890
[TBL] [Abstract][Full Text] [Related]
13. Biopolymer fouling in dead-end ultrafiltration of treated domestic wastewater.
Zheng X; Ernst M; Huck PM; Jekel M
Water Res; 2010 Oct; 44(18):5212-21. PubMed ID: 20637488
[TBL] [Abstract][Full Text] [Related]
14. Natural organic matter fouling of low-pressure, hollow-fiber membranes: Effects of NOM source and hydrodynamic conditions.
Huang H; Lee N; Young T; Gary A; Lozier JC; Jacangelo JG
Water Res; 2007 Sep; 41(17):3823-32. PubMed ID: 17644151
[TBL] [Abstract][Full Text] [Related]
15. Effect of filtration mode and backwash water on hydraulically irreversible fouling of ultrafiltration membrane.
Chang H; Liu B; Liang H; Yu H; Shao S; Li G
Chemosphere; 2017 Jul; 179():254-264. PubMed ID: 28371709
[TBL] [Abstract][Full Text] [Related]
16. Differential natural organic matter fouling of ceramic versus polymeric ultrafiltration membranes.
Lee SJ; Kim JH
Water Res; 2014 Jan; 48():43-51. PubMed ID: 24238879
[TBL] [Abstract][Full Text] [Related]
17. Microfiltration of different surface waters with/without coagulation: clear correlations between membrane fouling and hydrophilic biopolymers.
Kimura K; Tanaka K; Watanabe Y
Water Res; 2014 Feb; 49():434-43. PubMed ID: 24210507
[TBL] [Abstract][Full Text] [Related]
18. Effect of coagulation on fouling potential and removal of algal organic matter in ultrafiltration pretreatment to seawater reverse osmosis.
Alizadeh Tabatabai SA; Schippers JC; Kennedy MD
Water Res; 2014 Aug; 59():283-94. PubMed ID: 24810744
[TBL] [Abstract][Full Text] [Related]
19. Stabilization of flux during dead-end ultra-low pressure ultrafiltration.
Peter-Varbanets M; Hammes F; Vital M; Pronk W
Water Res; 2010 Jun; 44(12):3607-16. PubMed ID: 20488503
[TBL] [Abstract][Full Text] [Related]
20. Complexity of ultrafiltration membrane fouling caused by macromolecular dissolved organic compounds in secondary effluents.
Haberkamp J; Ernst M; Böckelmann U; Szewzyk U; Jekel M
Water Res; 2008 Jun; 42(12):3153-61. PubMed ID: 18423516
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]