BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 19556761)

  • 1. Current situation of endotoxin retentive filter.
    Tsuchida K; Nakamura M; Yoshikawa K; Minakuchi J; Takesawa S
    Blood Purif; 2009; 27 Suppl 1():28-35. PubMed ID: 19556761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standard on microbiological management of fluids for hemodialysis and related therapies by the Japanese Society for Dialysis Therapy 2008.
    Kawanishi H; Akiba T; Masakane I; Tomo T; Mineshima M; Kawasaki T; Hirakata H; Akizawa T
    Ther Apher Dial; 2009 Apr; 13(2):161-6. PubMed ID: 19379157
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bacteriological water quality in the central dialysis fluid delivery system from the survey of the Japanese Society for Dialysis Therapy.
    Masakane I; Takemoto Y; Nakai S; Tsubakihara Y; Akiba T; Watanabe Y; Iseki K
    Blood Purif; 2009; 27 Suppl 1():11-6. PubMed ID: 19556757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bacteriological qualities of dialysis fluid in Japan as of 31 December 2006.
    Masakane I; Tsubakihara Y; Akiba T; Watanabe Y; Iseki K
    Ther Apher Dial; 2008 Dec; 12(6):457-63. PubMed ID: 19140843
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Purification of dialysis water in the central dialysis fluid delivery system in Japan: a prospective observation study.
    Uchino J; Kawasaki T
    Blood Purif; 2009; 27 Suppl 1():64-9. PubMed ID: 19556766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Advances and advantages in recent central dialysis fluid delivery system.
    Koda Y; Mineshima M
    Blood Purif; 2009; 27 Suppl 1():23-7. PubMed ID: 19556760
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The performance evaluation of endotoxin retentive filters in haemodialysis.
    Kashiwagi T; Sato K; Kawakami S; Kiyomoto M; Takei H; Suzuki T; Genei H; Nakata H; Iino Y; Katayama Y
    J Nippon Med Sch; 2011; 78(4):214-23. PubMed ID: 21869555
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Standardization of water purification in the central dialysis fluid delivery system: validation and parametric method.
    Tomo T; Shinoda T
    Blood Purif; 2009; 27 Suppl 1():36-40. PubMed ID: 19556762
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Central online hemodiafiltration in Japan: management of water quality and practice.
    Yamashita AC; Sato T
    Blood Purif; 2009; 27 Suppl 1():50-5. PubMed ID: 19556764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The new standard of fluids for hemodialysis in Japan.
    Kawanishi H; Masakane I; Tomo T
    Blood Purif; 2009; 27 Suppl 1():5-10. PubMed ID: 19556756
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Leakage of Endotoxins through the Endotoxin Retentive Filter: An in vitro Study.
    Nozaki H; Tange Y; Inada Y; Uchino T; Azuma N
    Blood Purif; 2022; 51(10):831-839. PubMed ID: 35021168
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Particulates formed in online prepared substitution fluid-Effect of acetic acid cleaning on endotoxin retentive filters.
    Imai M; Yamamoto M; Togo K; Yamashita AC
    Ther Apher Dial; 2022 Dec; 26(6):1193-1201. PubMed ID: 35415877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro assessment of dialysis membrane as an endotoxin transfer barrier: geometry, morphology, and permeability.
    Henrie M; Ford C; Andersen M; Stroup E; Diaz-Buxo J; Madsen B; Britt D; Ho CH
    Artif Organs; 2008 Sep; 32(9):701-10. PubMed ID: 18684209
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fully automated dialysis system based on the central dialysis fluid delivery system.
    Kawanishi H; Moriishi M; Sato T; Taoka M
    Blood Purif; 2009; 27 Suppl 1():56-63. PubMed ID: 19556765
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dialysate purification after introduction of automated hot water disinfection system to central dialysis fluid delivery system.
    Ogawa T; Matsuda A; Yamaguchi Y; Sasaki Y; Kanayama Y; Maeda T; Noiri C; Hasegawa H; Matsumura O; Mitarai T
    ASAIO J; 2012; 58(2):127-31. PubMed ID: 22370682
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Guidance of technical management of dialysis water and dialysis fluid for the Japan Association for Clinical Engineering Technologists.
    Kawasaki T; Uchino J; Shinoda T; Kawanishi H;
    Blood Purif; 2009; 27 Suppl 1():41-9. PubMed ID: 19556763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrapure dialysis fluid: improving conventional and daily dialysis.
    Ledebo I
    Hemodial Int; 2004 Apr; 8(2):159-66. PubMed ID: 19379412
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrapure dialysis fluid--direct and indirect benefits in dialysis therapy.
    Ledebo I
    Blood Purif; 2004; 22 Suppl 2():20-5. PubMed ID: 15655318
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2011 JSDT standard on the management of endotoxin retentive filter for dialysis and related therapies.
    Masakane I; Kawanishi H; Mineshima M; Takemoto Y; Uchino J; Hoshino T; Igoshi T; Hirakata H; Akizawa T;
    Ther Apher Dial; 2013 Apr; 17(2):229-40. PubMed ID: 23551680
    [No Abstract]   [Full Text] [Related]  

  • 20. Ultrapure dialysate: facts and myths.
    Bommer J; Jaber BL
    Semin Dial; 2006; 19(2):115-9. PubMed ID: 16551288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.