145 related articles for article (PubMed ID: 19556800)
1. How to prevent lateral thermal damage to tissue using the harmonic scalpel: experimental study on pig small intestine and abdominal wall.
Pogorelić Z; Perko Z; Druzijanić N; Tomić S; Mrklić I
Eur Surg Res; 2009; 43(2):235-40. PubMed ID: 19556800
[TBL] [Abstract][Full Text] [Related]
2. Lateral thermal damage to rat abdominal wall after harmonic scalpel application.
Perko Z; Pogorelić Z; Bilan K; Tomić S; Vilović K; Krnić D; Druzijanić N; Kraljević D; Juricić J
Surg Endosc; 2006 Feb; 20(2):322-4. PubMed ID: 16333532
[TBL] [Abstract][Full Text] [Related]
3. Noninvasive vasectomy using a focused ultrasound clip: thermal measurements and simulations.
Fried NM; Sinelnikov YD; Pant BB; Roberts WW; Solomon SB
IEEE Trans Biomed Eng; 2001 Dec; 48(12):1453-9. PubMed ID: 11759926
[TBL] [Abstract][Full Text] [Related]
4. Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure.
Družijanić N; Pogorelić Z; Perko Z; Mrklić I; Tomić S
Can J Surg; 2012 Oct; 55(5):317-21. PubMed ID: 22854112
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the ultrasonic scalpel to CO2 laser and electrosurgery in terms of tissue injury and adhesion formation in a rabbit model.
Schemmel M; Haefner HK; Selvaggi SM; Warren JS; Termin CS; Hurd WW
Fertil Steril; 1997 Feb; 67(2):382-6. PubMed ID: 9022618
[TBL] [Abstract][Full Text] [Related]
6. How can we safely use ultrasonic laparoscopic coagulating shears?
Kim JS; Hattori R; Yamamoto T; Yoshino Y; Gotoh M
Int J Urol; 2010 Apr; 17(4):377-81. PubMed ID: 20409232
[TBL] [Abstract][Full Text] [Related]
7. Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic Scalpel and the Ligasure.
Sutton PA; Awad S; Perkins AC; Lobo DN
Br J Surg; 2010 Mar; 97(3):428-33. PubMed ID: 20101674
[TBL] [Abstract][Full Text] [Related]
8. Comparison of safety and efficacy of ultrasonic and bipolar thermal energy: an experimental study.
Diamantis T; Gialikaris S; Kontos M; Gakiopoulou C; Felekouras E; Papalois A; Agrogiannis G; Patsouris E; Bastounis E
Surg Laparosc Endosc Percutan Tech; 2008 Aug; 18(4):384-90. PubMed ID: 18716539
[TBL] [Abstract][Full Text] [Related]
9. Comparison of in vivo clinical performance and shaft temperature and in vitro tissue temperature and transection times between new and reprocessed harmonic scalpels.
Lester BR; Miller K; Boers A; Harris DC; Gamble WG
Surg Laparosc Endosc Percutan Tech; 2010 Oct; 20(5):e150-9. PubMed ID: 20975490
[TBL] [Abstract][Full Text] [Related]
10. Ultrasonic scalpel for sealing of the thoracic duct: evaluation of effectiveness in an animal model.
Nakayama H; Ito H; Kato Y; Tsuboi M
Interact Cardiovasc Thorac Surg; 2009 Sep; 9(3):399-401. PubMed ID: 19564208
[TBL] [Abstract][Full Text] [Related]
11. Tissue response to surgical energy devices.
Phillips CK; Hruby GW; Durak E; Lehman DS; Humphrey PA; Mansukhani MM; Landman J
Urology; 2008 Apr; 71(4):744-8. PubMed ID: 18289646
[TBL] [Abstract][Full Text] [Related]
12. Hereditary hemorrhagic telangiectasis treated by the harmonic scalpel.
Ishibashi T; Takamatsu S
Head Neck; 2003 Apr; 25(4):333-6. PubMed ID: 12658738
[TBL] [Abstract][Full Text] [Related]
13. Can harmonic focus curved shear effectively seal the pancreatic ducts and prevent pancreatic leak? Feasibility evaluation and testing in ex vivo and in vivo porcine models.
Chamberlain RS; Korvick D; Mootoo M; Story S; Dubiel B; Sharpnack D
J Surg Res; 2009 Dec; 157(2):279-83. PubMed ID: 19765731
[TBL] [Abstract][Full Text] [Related]
14. [Laparoscopic manual intestinal anastomosis: experimental study in a pig model].
Fritsch S; Fourquier P; Gossot D; Colomer S; Celerier M; Revillon Y
Ann Chir; 1998; 52(6):574-7. PubMed ID: 9752510
[No Abstract] [Full Text] [Related]
15. Prevention and treatment of abdominal wall bleeding complications at trocar sites: review of the literature.
Vázquez-Frias JA; Huete-Echandi F; Cueto-Garcia J; Padilla-Paz LA
Surg Laparosc Endosc Percutan Tech; 2009 Jun; 19(3):195-7. PubMed ID: 19542844
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the harmonic scalpel and the ultrasonic surgical aspirator in subsegmental lung resections: an experimental study.
Samancilar O; Cakan A; Cetin Y; Cagirici U; Veral A; Zeytunlu M; Turhan K; Kilic M; Askar FZ
Thorac Cardiovasc Surg; 2007 Dec; 55(8):509-11. PubMed ID: 18027338
[TBL] [Abstract][Full Text] [Related]
17. Ultracision: the harmonic scalpel and its possible uses in maxillofacial surgery.
Sherman JA; Davies HT
Br J Oral Maxillofac Surg; 2000 Oct; 38(5):530-2. PubMed ID: 11010788
[TBL] [Abstract][Full Text] [Related]
18. Experimental and clinical evaluation of the harmonic scalpel in thoracic surgery.
Hayashi A; Takamori S; Matsuo T; Tayama K; Mitsuoka M; Shirouzu K
Kurume Med J; 1999; 46(1):25-9. PubMed ID: 10319610
[TBL] [Abstract][Full Text] [Related]
19. Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.
Pons Y; Gauthier J; Ukkola-Pons E; Clément P; Roguet E; Poncet JL; Conessa C
Otolaryngol Head Neck Surg; 2009 Oct; 141(4):496-501. PubMed ID: 19786219
[TBL] [Abstract][Full Text] [Related]
20. Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery.
Hefermehl LJ; Largo RA; Hermanns T; Poyet C; Sulser T; Eberli D
BJU Int; 2014 Aug; 114(2):245-52. PubMed ID: 24127773
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]