These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 19560148)

  • 1. Effects of body configuration on pelvic injury in backward fall simulation using 3D finite element models of pelvis-femur-soft tissue complex.
    Majumder S; Roychowdhury A; Pal S
    J Biomech; 2009 Jul; 42(10):1475-1482. PubMed ID: 19560148
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simulation of hip fracture in sideways fall using a 3D finite element model of pelvis-femur-soft tissue complex with simplified representation of whole body.
    Majumder S; Roychowdhury A; Pal S
    Med Eng Phys; 2007 Dec; 29(10):1167-78. PubMed ID: 17270483
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of trochanteric soft tissue thickness and hip impact velocity on hip fracture in sideways fall through 3D finite element simulations.
    Majumder S; Roychowdhury A; Pal S
    J Biomech; 2008 Sep; 41(13):2834-42. PubMed ID: 18718597
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis of hip fracture risk in elderly female: The effects of soft tissue shape, fall direction, and interventions.
    Murakami S; Zhao Y; Mizuno K; Yamada M; Yokoyama Y; Yamada Y; Jinzaki M
    J Biomech; 2024 Jul; 172():112199. PubMed ID: 38959821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact.
    Fleps I; Enns-Bray WS; Guy P; Ferguson SJ; Cripton PA; Helgason B
    PLoS One; 2018; 13(8):e0200952. PubMed ID: 30114192
    [TBL] [Abstract][Full Text] [Related]  

  • 6. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?
    Schileo E; Balistreri L; Grassi L; Cristofolini L; Taddei F
    J Biomech; 2014 Nov; 47(14):3531-8. PubMed ID: 25261321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hip fracture and anthropometric variations: dominance among trochanteric soft tissue thickness, body height and body weight during sideways fall.
    Majumder S; Roychowdhury A; Pal S
    Clin Biomech (Bristol); 2013; 28(9-10):1034-40. PubMed ID: 24139746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preventing fall-related vertebral fractures: effect of floor stiffness on peak impact forces during backward falls.
    Sran MM; Robinovitch SN
    Spine (Phila Pa 1976); 2008 Aug; 33(17):1856-62. PubMed ID: 18670338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of body configuration on the strain magnitude and distribution within the acetabulum during sideways falls: A finite element approach.
    Khakpour S; Tanska P; Saarakkala S; Korhonen RK; Jämsä T
    J Biomech; 2021 Jan; 114():110156. PubMed ID: 33302183
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transmission of force in the lumbosacral spine during backward falls.
    Van Toen C; Sran MM; Robinovitch SN; Cripton PA
    Spine (Phila Pa 1976); 2012 Apr; 37(9):E519-27. PubMed ID: 22076645
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of boundary condition on the biomechanics of a human pelvic joint under an axial compressive load: a three-dimensional finite element model.
    Hao Z; Wan C; Gao X; Ji T
    J Biomech Eng; 2011 Oct; 133(10):101006. PubMed ID: 22070331
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The finite element modeling of human pelvis and its application in medicolegal expertise].
    Li ZD; Zou DH; Liu NG; Huang P; Chen YJ
    Fa Yi Xue Za Zhi; 2010 Dec; 26(6):406-12. PubMed ID: 21425599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Can CT image deblurring improve finite element predictions at the proximal femur?
    Falcinelli C; Schileo E; Pakdel A; Whyne C; Cristofolini L; Taddei F
    J Mech Behav Biomed Mater; 2016 Oct; 63():337-351. PubMed ID: 27450036
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Study of stress variations in single-stance and sideways fall using image-based finite element analysis.
    Faisal TR; Luo Y
    Biomed Mater Eng; 2016 May; 27(1):1-14. PubMed ID: 27175463
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Orthotropic HR-pQCT-based FE models improve strength predictions for stance but not for side-way fall loading compared to isotropic QCT-based FE models of human femurs.
    Luisier B; Dall'Ara E; Pahr DH
    J Mech Behav Biomed Mater; 2014 Apr; 32():287-299. PubMed ID: 24508715
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Penn State Safety Floor: Part II--Reduction of fall-related peak impact forces on the femur.
    Casalena JA; Badre-Alam A; Ovaert TC; Cavanagh PR; Streit DA
    J Biomech Eng; 1998 Aug; 120(4):527-32. PubMed ID: 10412424
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element study of human pelvis model in side impact for Chinese adult occupants.
    Ma Z; Lan F; Chen J; Liu W
    Traffic Inj Prev; 2015; 16(4):409-17. PubMed ID: 25133596
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prediction of the pathological fracture risk during stance and fall-loading configurations for metastases in the proximal femur, using a computed tomography-based finite element method.
    Shinoda Y; Kobayashi H; Kaneko M; Ohashi S; Bessho M; Hayashi N; Oka H; Imanishi J; Sawada R; Ogura K; Tanaka S; Haga N; Kawano H
    J Orthop Sci; 2019 Nov; 24(6):1074-1080. PubMed ID: 31521453
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel sideways fall simulator to study hip fractures ex vivo.
    Fleps I; Vuille M; Melnyk A; Ferguson SJ; Guy P; Helgason B; Cripton PA
    PLoS One; 2018; 13(7):e0201096. PubMed ID: 30040858
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Development and validating of a three-dimensional finite element model of total human pelvis].
    Cheng LM; Jia YW; Yu GR; Du CF; Yu Y; Lou YJ; Ding ZQ
    Zhonghua Yi Xue Za Zhi; 2007 Dec; 87(47):3346-8. PubMed ID: 18478949
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.