These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 19572881)
1. Re: "Strategy to eliminate inappropriate shocks secondary to T-wave oversensing in a biventricular ICD". Alsheikh T Pacing Clin Electrophysiol; 2009 Jul; 32(7):963; author reply 963. PubMed ID: 19572881 [No Abstract] [Full Text] [Related]
2. T-wave oversensing and inappropriate shocks: a case report. Srivathsan K; Scott LR; Altemose GT Europace; 2008 May; 10(5):552-5. PubMed ID: 18442965 [TBL] [Abstract][Full Text] [Related]
3. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
4. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing. Gilliam FR J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033 [TBL] [Abstract][Full Text] [Related]
5. Hyperkalemia induced T wave oversensing leading to loss of biventricular pacing and inappropriate ICD shocks. Koul AK; Keller S; Clancy JF; Lampert R; Batsford WP; Rosenfeld LE Pacing Clin Electrophysiol; 2004 May; 27(5):681-3. PubMed ID: 15125731 [TBL] [Abstract][Full Text] [Related]
12. T-wave oversensing by an implantable cardioverter defibrillator after successful ablation of idiopathic ventricular fibrillation. Strohmer B; Schernthaner C; Pichler M Pacing Clin Electrophysiol; 2006 Apr; 29(4):431-5. PubMed ID: 16650276 [TBL] [Abstract][Full Text] [Related]
13. Unusual cause for an increase of the sensing integrity counter in a patient with inappropriate implantable cardioverter-defibrillator therapy. Vollmann D; Lüthje L; Zabel M Europace; 2007 May; 9(5):275-7. PubMed ID: 17369268 [TBL] [Abstract][Full Text] [Related]
14. Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions. Rauwolf T; Guenther M; Hass N; Schnabel A; Bock M; Braun MU; Strasser RH Europace; 2007 Nov; 9(11):1041-7. PubMed ID: 17897927 [TBL] [Abstract][Full Text] [Related]
15. Inappropriate shocks in a patient treated with a cardioverter defibrillator. Hutse W; Tavernier R; Jordaens L Heart; 1997 Apr; 77(4):386-7. PubMed ID: 9155627 [No Abstract] [Full Text] [Related]
16. An unusual cause of oversensing leading to inappropriate ICD discharges. Spencker S; Poppelbaum A; Müller D Int J Cardiol; 2008 Sep; 129(1):e24-6. PubMed ID: 17669521 [TBL] [Abstract][Full Text] [Related]
17. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine. Chongtham DS; Bahl A; Kumar RM; Talwar KK Int J Cardiol; 2007 May; 118(2):e44-5. PubMed ID: 17395291 [TBL] [Abstract][Full Text] [Related]
18. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms. Kowalski M; Ellenbogen KA; Wood MA; Friedman PL Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976 [TBL] [Abstract][Full Text] [Related]
20. Inappropriate shock during left ventricular threshold measurement in a patient with coexisting ICD and a biventricular pacemaker. Azizi M; Nägele H Herzschrittmacherther Elektrophysiol; 2007 Jun; 18(2):101-4. PubMed ID: 17646942 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]