These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 19572932)

  • 21. A clinical determination of optimal fresh gas flow in a baby EAR circuit.
    Theerapongpakdee S; Phanpanusit T; Horatanaruang D; Bunsangjaroen P; Limpkulwathanaporn P; Thananun M; Nonlhaopol D
    J Med Assoc Thai; 2009 May; 92(5):667-71. PubMed ID: 19459529
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Assessing the clinical or pharmaco-economical benefit of target controlled desflurane delivery in surgical patients using the Zeus anaesthesia machine.
    Lortat-Jacob B; Billard V; Buschke W; Servin F
    Anaesthesia; 2009 Nov; 64(11):1229-35. PubMed ID: 19825059
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Inhalation induction using sevoflurane in children: the single-breath vital capacity technique compared to the tidal volume technique*.
    Lejus C; Bazin V; Fernandez M; Nguyen JM; Radosevic A; Quere MF; Le Roux C; Le Corre A; Pinaud M
    Anaesthesia; 2006 Jun; 61(6):535-40. PubMed ID: 16704586
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of the maintenance and recovery charcateristic of sevoflurane-nitrous oxide against isoflurane-nitrous oxide anaesthesia.
    Chiu CL; Chan YK; Ong GS; Delilkan AE
    Singapore Med J; 2000 Nov; 41(11):530-3. PubMed ID: 11284610
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Techniques for administering inhalation anesthetic agents, professional exposure, and early neurobehavioral effects].
    Proietti L; Longo B; Gulino S; Duscio D
    Med Lav; 2003; 94(4):374-9. PubMed ID: 14526496
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Patient disconnect.
    Collins LM; Vaghadia H
    Can J Anaesth; 1998 Nov; 45(11):1135. PubMed ID: 10021974
    [No Abstract]   [Full Text] [Related]  

  • 27. [A comparative analysis of haemodynamics and oxygen transport during xenon and nitrous oxide anaesthesia in endoscopic surgery in gynaecology].
    Belov AV; Sokologorskiĭ SV; Shifman EM
    Anesteziol Reanimatol; 2010; (6):25-9. PubMed ID: 21400793
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Brief review: theory and practice of minimal fresh gas flow anesthesia.
    Brattwall M; Warrén-Stomberg M; Hesselvik F; Jakobsson J
    Can J Anaesth; 2012 Aug; 59(8):785-97. PubMed ID: 22653840
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Model for the administration of low-flow anaesthesia.
    Beams DM; Sasse FJ; Webster JG; Radwin RG
    Br J Anaesth; 1998 Aug; 81(2):161-70. PubMed ID: 9813516
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An alternative method of nitrous oxide delivery into a minimal-flow circle breathing system.
    Nel MR; Watts JD; Lockwood GG
    Anaesthesia; 1997 Jan; 52(1):57-61. PubMed ID: 9014546
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Model-based administration of inhalation anaesthesia. 3. Validating the system model.
    Lerou JG; Booij LH
    Br J Anaesth; 2002 Jan; 88(1):24-37. PubMed ID: 11883376
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Model-based administration of inhalation anaesthesia. 4. Applying the system model.
    Lerou JG; Verheijen R; Booij LH
    Br J Anaesth; 2002 Feb; 88(2):175-83. PubMed ID: 11883384
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Physiologically precise simulation of multiple lung gas exchange during anaesthesia by simultaneous gas infusion and extraction.
    Peyton P; Ramani P; Stuart-Andrews C; Junor P; Robinson G
    Physiol Meas; 2005 Dec; 26(6):965-78. PubMed ID: 16311445
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Uptake of enflurane and isoflurane during spontaneous and controlled ventilation.
    Bengtson JP; Bengtsson A; Stengvist O
    Anaesth Intensive Care; 1992 May; 20(2):191-5. PubMed ID: 1534467
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia.
    Curatolo M; Derighetti M; Petersen-Felix S; Feigenwinter P; Fischer M; Zbinden AM
    Br J Anaesth; 1996 Feb; 76(2):245-50. PubMed ID: 8777105
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Use of medical simulation to explore equipment failures and human-machine interactions in anesthesia machine pipeline supply crossover.
    Mudumbai SC; Fanning R; Howard SK; Davies MF; Gaba DM
    Anesth Analg; 2010 May; 110(5):1292-6. PubMed ID: 20418294
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Oxygen concentrators performance with nitrous oxide at 50:50 volume.
    Moll JR; Vieira JE; Gozzani JL; Mathias LA
    Braz J Anesthesiol; 2014; 64(3):164-8. PubMed ID: 24907874
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Isoflurane in a circle system with low gas flow.
    Revell SP; Tayler DH
    Br J Anaesth; 1987 Oct; 59(10):1219-22. PubMed ID: 3676052
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Field use of isoflurane as an inhalant anesthetic in the American marten (Martes americana).
    Desmarchelier M; Cheveau M; Imbeau L; Lair S
    J Wildl Dis; 2007 Oct; 43(4):719-25. PubMed ID: 17984268
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Economics of low-flow anaesthesia in children.
    Perkins R; Meakin G
    Anaesthesia; 1996 Dec; 51(12):1089-92. PubMed ID: 9038437
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.