These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 19572955)

  • 1. Feasibility and safety of using an esophageal protective system to eliminate esophageal thermal injury: implications on atrial-esophageal fistula following AF ablation.
    Arruda MS; Armaganijan L; Di Biase L; Rashidi R; Natale A
    J Cardiovasc Electrophysiol; 2009 Nov; 20(11):1272-8. PubMed ID: 19572955
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein.
    Yokoyama K; Nakagawa H; Seres KA; Jung E; Merino J; Zou Y; Ikeda A; Pitha JV; Lazzara R; Jackman WM
    Circ Arrhythm Electrophysiol; 2009 Feb; 2(1):41-9. PubMed ID: 19808443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: a pilot study.
    Tsuchiya T; Ashikaga K; Nakagawa S; Hayashida K; Kugimiya H
    J Cardiovasc Electrophysiol; 2007 Feb; 18(2):145-50. PubMed ID: 17239114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation.
    Di Biase L; Saenz LC; Burkhardt DJ; Vacca M; Elayi CS; Barrett CD; Horton R; Bai R; Siu A; Fahmy TS; Patel D; Armaganijan L; Wu CT; Kai S; Ching CK; Phillips K; Schweikert RA; Cummings JE; Arruda M; Saliba WI; Dodig M; Natale A
    Circ Arrhythm Electrophysiol; 2009 Apr; 2(2):108-12. PubMed ID: 19808454
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation.
    Ripley KL; Gage AA; Olsen DB; Van Vleet JF; Lau CP; Tse HF
    J Cardiovasc Electrophysiol; 2007 Jun; 18(6):642-6. PubMed ID: 17428270
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical esophageal displacement during catheter ablation for atrial fibrillation.
    Koruth JS; Reddy VY; Miller MA; Patel KK; Coffey JO; Fischer A; Gomes JA; Dukkipati S; D'Avila A; Mittnacht A
    J Cardiovasc Electrophysiol; 2012 Feb; 23(2):147-54. PubMed ID: 21914018
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retro-cardiac esophageal mobility and deflection to prevent thermal injury during atrial fibrillation ablation: an anatomic feasibility study.
    Kanjwal K; Yeasting R; Maloney JD; Baptista C; Elsamaloty H; Sheikh M; Elahinia M; Anderson W; Maloney JD
    J Interv Card Electrophysiol; 2011 Jan; 30(1):45-53. PubMed ID: 21165685
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Esophageal imaging and strategies for avoiding injury during left atrial ablation for atrial fibrillation.
    Ren JF; Lin D; Marchlinski FE; Callans DJ; Patel V
    Heart Rhythm; 2006 Oct; 3(10):1156-61. PubMed ID: 17018343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safe and effective ablation of atrial fibrillation: importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation.
    Kuwahara T; Takahashi A; Kobori A; Miyazaki S; Takahashi Y; Takei A; Nozato T; Hikita H; Sato A; Aonuma K
    J Cardiovasc Electrophysiol; 2009 Jan; 20(1):1-6. PubMed ID: 18775045
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias.
    Halm U; Gaspar T; Zachäus M; Sack S; Arya A; Piorkowski C; Knigge I; Hindricks G; Husser D
    Am J Gastroenterol; 2010 Mar; 105(3):551-6. PubMed ID: 19888201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanisms of phrenic nerve injury during radiofrequency ablation at the pulmonary vein orifice.
    Bunch TJ; Bruce GK; Mahapatra S; Johnson SB; Miller DV; Sarabanda AV; Milton MA; Packer DL
    J Cardiovasc Electrophysiol; 2005 Dec; 16(12):1318-25. PubMed ID: 16403064
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: comparison between 8 mm tip and open irrigation catheters.
    Cummings JE; Barrett CD; Litwak KN; DI Biase L; Chowdhury P; Oh S; Ching CK; Saliba WI; Schweikert RA; Burkhardt JD; DE Marco S; Armaganijan L; Natale A
    J Cardiovasc Electrophysiol; 2008 Jun; 19(6):641-4. PubMed ID: 18373604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Oesophageal cooling with ice water does not reduce the incidence of oesophageal lesions complicating catheter ablation of atrial fibrillation: randomized controlled study.
    Kuwahara T; Takahashi A; Okubo K; Takagi K; Yamao K; Nakashima E; Kawaguchi N; Takigawa M; Watari Y; Sugiyama T; Handa K; Kimura S; Hikita H; Sato A; Aonuma K
    Europace; 2014 Jun; 16(6):834-9. PubMed ID: 24469436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases.
    Mateos JC; Mateos EI; Peña TG; Lobo TJ; Mateos JC; Vargas RN; Pachón CT; Acosta JC
    Rev Bras Cir Cardiovasc; 2015; 30(2):139-47. PubMed ID: 26107444
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Esophageal damage during radiofrequency ablation of atrial fibrillation: impact of energy settings, lesion sets, and esophageal visualization.
    Martinek M; Bencsik G; Aichinger J; Hassanein S; Schoefl R; Kuchinka P; Nesser HJ; Purerfellner H
    J Cardiovasc Electrophysiol; 2009 Jul; 20(7):726-33. PubMed ID: 19207781
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: a single-catheter approach to pulmonary vein antrum isolation.
    Arruda MS; He DS; Friedman P; Nakagawa H; Bruce C; Azegami K; Anders R; Kozel P; Chiavetta A; Marad P; MacAdam D; Jackman W; Wilber DJ
    J Cardiovasc Electrophysiol; 2007 Feb; 18(2):206-11. PubMed ID: 17338769
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of cool tip versus 8-mm tip catheter in achieving electrical isolation of pulmonary veins for long-term control of atrial fibrillation: a prospective randomized pilot study.
    Dixit S; Gerstenfeld EP; Callans DJ; Cooper JM; Lin D; Russo AM; Verdino RJ; Patel VV; Kimmel SE; Ratcliffe SJ; Hsia HH; Nayak HM; Zado E; Ren JF; Marchlinski FE
    J Cardiovasc Electrophysiol; 2006 Oct; 17(10):1074-9. PubMed ID: 16879626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time monitoring of luminal esophageal temperature during left atrial radiofrequency catheter ablation for atrial fibrillation: observations about esophageal heating during ablation at the pulmonary vein ostia and posterior left atrium.
    Perzanowski C; Teplitsky L; Hranitzky PM; Bahnson TD
    J Cardiovasc Electrophysiol; 2006 Feb; 17(2):166-70. PubMed ID: 16533254
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Esophageal injury and temperature monitoring during atrial fibrillation ablation.
    Singh SM; d'Avila A; Doshi SK; Brugge WR; Bedford RA; Mela T; Ruskin JN; Reddy VY
    Circ Arrhythm Electrophysiol; 2008 Aug; 1(3):162-8. PubMed ID: 19808410
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prevention of atrial-esophageal fistula after catheter ablation of atrial fibrillation.
    Dagres N; Anastasiou-Nana M
    Curr Opin Cardiol; 2011 Jan; 26(1):1-5. PubMed ID: 21099683
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.