176 related articles for article (PubMed ID: 19579524)
1. Effect of implant design on initial stability of tapered implants.
Chong L; Khocht A; Suzuki JB; Gaughan J
J Oral Implantol; 2009; 35(3):130-5. PubMed ID: 19579524
[TBL] [Abstract][Full Text] [Related]
2. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone.
Kim YS; Lim YJ
Clin Oral Implants Res; 2011 Oct; 22(10):1179-1184. PubMed ID: 21320170
[TBL] [Abstract][Full Text] [Related]
3. Self-cutting blades and their influence on primary stability of tapered dental implants in a simulated low-density bone model: a laboratory study.
Kim DR; Lim YJ; Kim MJ; Kwon HB; Kim SH
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Nov; 112(5):573-80. PubMed ID: 21439865
[TBL] [Abstract][Full Text] [Related]
4. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
[TBL] [Abstract][Full Text] [Related]
5. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754
[TBL] [Abstract][Full Text] [Related]
6. Resonance frequency analysis measurements of implants at placement surgery.
Ostman PO; Hellman M; Wendelhag I; Sennerby L
Int J Prosthodont; 2006; 19(1):77-83; discussion 84. PubMed ID: 16479765
[TBL] [Abstract][Full Text] [Related]
7. Influence of implant geometry on primary insertion stability and simulated peri-implant bone loss: an in vitro study using resonance frequency analysis and damping capacity assessment.
Lachmann S; Laval JY; Axmann D; Weber H
Int J Oral Maxillofac Implants; 2011; 26(2):347-55. PubMed ID: 21483888
[TBL] [Abstract][Full Text] [Related]
8. Identification of stability changes for immediately placed dental implants.
West JD; Oates TW
Int J Oral Maxillofac Implants; 2007; 22(4):623-30. PubMed ID: 17929524
[TBL] [Abstract][Full Text] [Related]
9. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants.
Kahraman S; Bal BT; Asar NV; Turkyilmaz I; Tözüm TF
J Oral Rehabil; 2009 Oct; 36(10):755-61. PubMed ID: 19758410
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study.
Marković A; Calvo-Guirado JL; Lazić Z; Gómez-Moreno G; Ćalasan D; Guardia J; Čolic S; Aguilar-Salvatierra A; Gačić B; Delgado-Ruiz R; Janjić B; Mišić T
Clin Implant Dent Relat Res; 2013 Jun; 15(3):341-9. PubMed ID: 22171668
[TBL] [Abstract][Full Text] [Related]
11. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.
Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL
J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592
[TBL] [Abstract][Full Text] [Related]
12. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants.
Al-Nawas B; Wagner W; Grötz KA
Int J Oral Maxillofac Implants; 2006; 21(5):726-32. PubMed ID: 17066633
[TBL] [Abstract][Full Text] [Related]
13. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
Çehreli S; Arman-Özçırpıcı A
Am J Orthod Dentofacial Orthop; 2012 Feb; 141(2):187-95. PubMed ID: 22284286
[TBL] [Abstract][Full Text] [Related]
14. Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study.
Tözüm TF; Bal BT; Turkyilmaz I; Gülay G; Tulunoglu I
J Oral Rehabil; 2010 Mar; 37(3):217-24. PubMed ID: 20002537
[TBL] [Abstract][Full Text] [Related]
15. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone.
Bilhan H; Geckili O; Mumcu E; Bozdag E; Sünbüloğlu E; Kutay O
J Oral Rehabil; 2010 Dec; 37(12):900-7. PubMed ID: 20529176
[TBL] [Abstract][Full Text] [Related]
16. Primary stability of turned and acid-etched screw-type implants: a removal torque and histomorphometric study in rabbits.
Fernandes Ede L; Unikowski IL; Teixeira ER; da Costa NP; Shinkai RS
Int J Oral Maxillofac Implants; 2007; 22(6):886-92. PubMed ID: 18271369
[TBL] [Abstract][Full Text] [Related]
17. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
Sul YT; Jönsson J; Yoon GS; Johansson C
Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742
[TBL] [Abstract][Full Text] [Related]
18. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
[TBL] [Abstract][Full Text] [Related]
19. Secondary stability assessment of titanium implants with an alkali-etched surface: a resonance frequency analysis study in beagle dogs.
Strnad J; Urban K; Povysil C; Strnad Z
Int J Oral Maxillofac Implants; 2008; 23(3):502-12. PubMed ID: 18700375
[TBL] [Abstract][Full Text] [Related]
20. Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials.
Bardyn T; Gédet P; Hallermann W; Büchler P
Int J Oral Maxillofac Implants; 2009; 24(6):1006-14. PubMed ID: 20162104
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]