These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 19580796)

  • 1. Interference on the laboratory measurement of bilirubin: the effect of in vitro interactions.
    de Cordova CM; Nogara MS; de Cordova MM
    Clin Chim Acta; 2009 Sep; 407(1-2):77-9. PubMed ID: 19580796
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of the interference due to haemoglobin, bilirubin and lipids on Immulite 2500 assays: a practical approach.
    Steen G; Klerk A; Laan Kv; Eppens EF
    Ann Clin Biochem; 2011 Mar; 48(Pt 2):170-5. PubMed ID: 21355012
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Serum bilirubin measurements in hemolyzed samples.
    McDonagh AF; Lo SF; Maisels MJ; Watchko JF
    Clin Chim Acta; 2011 Jun; 412(13-14):1275; author reply 1276. PubMed ID: 21439950
    [No Abstract]   [Full Text] [Related]  

  • 4. Evaluation of bilirubin concentration in hemolysed samples, is it really impossible? The altitude-curve cartography approach to interfered assays.
    Brunori P; Masi P; Faggiani L; Villani L; Tronchin M; Galli C; Laube C; Leoni A; Demi M; La Gioia A
    Clin Chim Acta; 2011 Apr; 412(9-10):774-7. PubMed ID: 21238446
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Some aspects of bilirubin determination in the newborn using dimethyl sulfoxide.
    Baginski ES; Epstein E; Zak B
    Ann Clin Lab Sci; 1980; 10(6):486-92. PubMed ID: 7447390
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].
    Gobert De Paepe E; Munteanu G; Schischmanoff PO; Porquet D
    Ann Biol Clin (Paris); 2008; 66(2):175-82. PubMed ID: 18390427
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Does bilirubin interfere with capillary electrophoresis of serum proteins?].
    Hellara I; Fekih O; Triki S; Elmay A; Neffati F; Najjar MF
    Ann Biol Clin (Paris); 2014; 72(1):124-8. PubMed ID: 24492101
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of the XAS test for sera screening with visible interference in the ARS analyzer].
    Soulier Majidi M; Ciupek C; Blanchard M; Quillet P
    Ann Biol Clin (Paris); 2001; 59(2):193-7. PubMed ID: 11282524
    [No Abstract]   [Full Text] [Related]  

  • 9. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.
    García-González E; Aramendía M; González-Tarancón R; Romero-Sánchez N; Rello L
    Clin Chem Lab Med; 2017 Jul; 55(8):1178-1185. PubMed ID: 28076302
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reassessment of the unbound concentrations of unconjugated bilirubin in relation to neurotoxicity in vitro.
    Ostrow JD; Pascolo L; Tiribelli C
    Pediatr Res; 2003 Dec; 54(6):926. PubMed ID: 14661625
    [No Abstract]   [Full Text] [Related]  

  • 11. An inter-laboratory survey of paediatric bilirubin analyses.
    St John A; Penberthy LA
    J Clin Pathol; 1979 Aug; 32(8):794-7. PubMed ID: 512039
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Use of a quantitative method of determination of blood bilirubin in clinical practice].
    Bogoiavlenskaia NV
    Lab Delo; 1974; 8(0):504. PubMed ID: 4139382
    [No Abstract]   [Full Text] [Related]  

  • 13. [Quantitative determination of the serum bilirubin level].
    Bakalova R
    Vutr Boles; 1974; 13(3):103-8. PubMed ID: 4446576
    [No Abstract]   [Full Text] [Related]  

  • 14. [Influence of visible interferences on biochemical assays realised on Au 5231, AU 5223 (Olympus) and CL 7200 (Shimadzu)].
    Frémont S; Combe AM; Mecrin M; Tronel H; Galland AV; Scholl C; Nicolas JP
    Ann Biol Clin (Paris); 1996; 54(8-9):309-20. PubMed ID: 9092310
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Matrix and bilirubin interference for high-sensitivity cardiac troponin I.
    Simons J; Beach L; Clark L; Kavsak PA
    Clin Chim Acta; 2015 Mar; 442():49-51. PubMed ID: 25603408
    [No Abstract]   [Full Text] [Related]  

  • 16. [Blood chemical analysis. F. Fluctuations in the bilirubin contents caused by changes in instrument, reagents, and sample containers used in the test].
    Iizuka K; Miyake K; Igari J
    Rinsho Byori; 1996 Nov; Suppl 103():187-91. PubMed ID: 9190405
    [No Abstract]   [Full Text] [Related]  

  • 17. How paraproteins can affect laboratory assays: spurious results and biological effects.
    King RI; Florkowski CM
    Pathology; 2010; 42(5):397-401. PubMed ID: 20632813
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biases in antibody-based single-phase assays for free thyroxine due to protein-bound analyte.
    Tanhehco YC; Peck Palmer OM; Derrico LS; Sepulveda JL; Blair HC
    Clin Chim Acta; 2009 Aug; 406(1-2):176-8. PubMed ID: 19500559
    [No Abstract]   [Full Text] [Related]  

  • 19. Should gender-related reference values be used for total bilirubin?
    Saegeman VS; Vierendeels I; Moens MJ; Moerman J
    Clin Chem Lab Med; 2009; 47(10):1309-10. PubMed ID: 19751143
    [No Abstract]   [Full Text] [Related]  

  • 20. [Changes in peripheral blood composition during 18- and 24-day cosmic flights].
    Legen'kov VI; Balakhovskiĭ IS; Beregovkin AV; Moshkalo ZS; Sorokina GV
    Kosm Biol Med; 1973; 7(1):39-45. PubMed ID: 4756285
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.