These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 19585854)

  • 21. Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial.
    Cune M; van Kampen F; van der Bilt A; Bosman F
    Int J Prosthodont; 2005; 18(2):99-105. PubMed ID: 15889656
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tissue-supported implant overdentures.
    Guerra LR; Finger IM; Block MS
    Implant Dent; 1992; 1(1):69-77. PubMed ID: 1288799
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mandibular implant-retained overdenture with magnets: a case report.
    Tan AS; Walmsley AD
    Dent Update; 2004 Mar; 31(2):104-8. PubMed ID: 15065374
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Magnetic denture retention systems: inexpensive and efficient.
    Gillings BR
    Int Dent J; 1984 Sep; 34(3):184-97. PubMed ID: 6384053
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Overdenture retained by teeth using a definitive denture base technique: a case report.
    Nascimento DF; dos Santos JF; Marchini L
    Eur J Prosthodont Restor Dent; 2010 Sep; 18(3):98-101. PubMed ID: 21077416
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of location and number of endosseous implants on retention and stability of magnetically retained mandibular overdentures: an in vitro study.
    Wahab LA; Sadig W
    Int J Prosthodont; 2008; 21(6):511-3. PubMed ID: 19149068
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The extent of maintenance required by implant-retained mandibular overdentures: a 3-year report.
    Davis DM; Rogers JO; Packer ME
    Int J Oral Maxillofac Implants; 1996; 11(6):767-74. PubMed ID: 8990639
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Bar overdentures utilizing the Locator attachment.
    Schneider AL; Kurtzman GM
    Gen Dent; 2001; 49(2):210-4. PubMed ID: 12004703
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A practical and predictable clinical technique to pick up stud attachments for implant-retained overdentures.
    Gittleman NB; Sayek S
    Pract Proced Aesthet Dent; 2006; 18(10):648, 650-1. PubMed ID: 17283696
    [No Abstract]   [Full Text] [Related]  

  • 30. [Denture stability in the partially edentulous jaw].
    Toyoda S; Morikawa M
    Hotetsu Rinsho; 1983; Spec No():146-52. PubMed ID: 6364100
    [No Abstract]   [Full Text] [Related]  

  • 31. Strain characteristics of Marburg double crown-retained implant overdentures compared with bar and ball-retained implant overdentures, with and without a rigid major connector.
    Kazokoğlu FŞ; Akaltan F
    J Prosthet Dent; 2014 Dec; 112(6):1416-24. PubMed ID: 24969407
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Implant-stabilized overdentures.
    Davis DM
    Dent Update; 1997 Apr; 24(3):106-9. PubMed ID: 9515375
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Implant supported overdentures--the Birmingham experience.
    Walmsley AD; Frame JW
    J Dent; 1997 Jan; 25 Suppl 1():S43-7. PubMed ID: 9080752
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Magnet retained overdentures using the Astra dental implant system.
    Walmsley AD; Brady CL; Smith PL; Frame JW
    Br Dent J; 1993 Jun; 174(11):399-404. PubMed ID: 8504028
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Masticatory function with mandibular implant-supported overdentures fitted with different attachment types.
    van der Bilt A; van Kampen FM; Cune MS
    Eur J Oral Sci; 2006 Jun; 114(3):191-6. PubMed ID: 16776767
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Does a prosthodontist spend more time providing mandibular two-implant overdentures than conventional dentures?
    Takanashi Y; Penrod JR; Chehade A; Klemetti E; Savard A; Lund JP; Feine JS
    Int J Prosthodont; 2002; 15(4):397-403. PubMed ID: 12170856
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values.
    Michelinakis G; Barclay CW; Smith PW
    Int J Prosthodont; 2006; 19(5):507-12. PubMed ID: 17323731
    [TBL] [Abstract][Full Text] [Related]  

  • 38. When to choose which retention element to use for removable dental prostheses.
    Zitzmann NU; Rohner U; Weiger R; Krastl G
    Int J Prosthodont; 2009; 22(2):161-7. PubMed ID: 19418863
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fabrication of a fractured mandibular bar-retained implant overdenture without implant-level impression making: a clinical report.
    Uludag B
    J Prosthodont; 2012 Dec; 21(8):622-5. PubMed ID: 22938207
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Viability of magnetic denture retainers: a 3-year case report.
    Thean HP; Khor SK; Loh PL
    Quintessence Int; 2001; 32(7):517-20. PubMed ID: 11495563
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.