  • 1. Comparing ceramic-metal to metal-metal total hip replacements--a simulator study of metal wear and ion release in 32- and 38-mm bearings.
    Ishida T; Clarke IC; Donaldson TK; Shirasu H; Shishido T; Yamamoto K
    J Biomed Mater Res B Appl Biomater; 2009 Nov; 91(2):887-896. PubMed ID: 19598291
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of ceramic-on-metal and metal-on-metal hip prostheses under adverse conditions.
    Williams S; Al-Hajjar M; Isaac GH; Fisher J
    J Biomed Mater Res B Appl Biomater; 2013 Jul; 101(5):770-5. PubMed ID: 23359608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
    Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
    Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface engineering: a low wearing solution for metal-on-metal hip surface replacements.
    Leslie IJ; Williams S; Brown C; Anderson J; Isaac G; Hatto P; Ingham E; Fisher J
    J Biomed Mater Res B Appl Biomater; 2009 Aug; 90(2):558-65. PubMed ID: 19195030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings.
    Halim T; Clarke IC; Burgett-Moreno MD; Donaldson TK; Savisaar C; Bowsher JG
    Bone Joint Res; 2014 Mar; 4(3):29-37. PubMed ID: 25736072
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear performance of ceramic-on-metal hip bearings.
    Reinders J; Sonntag R; Heisel C; Reiner T; Vot L; Kretzer JP
    PLoS One; 2013; 8(8):e73252. PubMed ID: 24009743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis.
    Firkins PJ; Tipper JL; Ingham E; Stone MH; Farrar R; Fisher J
    J Biomech; 2001 Oct; 34(10):1291-8. PubMed ID: 11522308
    [TBL] [Abstract][Full Text] [Related]  

  • 8. What is a "normal" wear pattern for metal-on-metal hip bearings?
    Bowsher JG; Clarke IC; Williams PA; Donaldson TK
    J Biomed Mater Res B Appl Biomater; 2009 Oct; 91(1):297-308. PubMed ID: 19582850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.
    Isaac GH; Brockett C; Breckon A; van der Jagt D; Williams S; Hardaker C; Fisher J; Schepers A
    J Bone Joint Surg Br; 2009 Sep; 91(9):1134-41. PubMed ID: 19721036
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations.
    Phipatanakul WP; Johnson SA; Good V; Clarke IC
    J Biomed Mater Res; 1998 Feb; 39(2):229-33. PubMed ID: 9457552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear of surface-engineered metal-on-metal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup.
    Leslie I; Williams S; Isaac G; Hatto P; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2013 Apr; 227(4):345-9. PubMed ID: 23637209
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Clinical efficacy and serum cobalt, chromium metal ion concentrations after total hip arthroplasty with three different hard-on-hard bearings].
    Cheng XW; Shen B; Zheng B; Yang J; Zhou ZK; Kang PD; Pei FX
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2013 Mar; 44(2):218-21, 230. PubMed ID: 23745259
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Alternative materials to improve total hip replacement tribology.
    Santavirta S; Böhler M; Harris WH; Konttinen YT; Lappalainen R; Muratoglu O; Rieker C; Salzer M
    Acta Orthop Scand; 2003 Aug; 74(4):380-8. PubMed ID: 14521286
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints.
    Koseki H; Tomita M; Yonekura A; Higuchi T; Sunagawa S; Baba K; Osaki M
    Int J Nanomedicine; 2017; 12():4111-4116. PubMed ID: 28615939
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants.
    Catelas I; Medley JB; Campbell PA; Huk OL; Bobyn JD
    J Biomed Mater Res B Appl Biomater; 2004 Aug; 70(2):167-78. PubMed ID: 15264297
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model.
    Oonishi H; Clarke IC; Good V; Amino H; Ueno M
    J Biomed Mater Res A; 2004 Sep; 70(4):523-32. PubMed ID: 15307156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial.
    Engh CA; Sritulanondha S; Korczak A; Whalen TD; Naudie DD; McCalden RW; MacDonald SJ
    Clin Orthop Relat Res; 2016 Feb; 474(2):447-55. PubMed ID: 26135473
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty?
    Khan M; Kuiper JH; Richardson JB
    Proc Inst Mech Eng H; 2007 Nov; 221(8):929-42. PubMed ID: 18161253
    [TBL] [Abstract][Full Text] [Related]  