These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

539 related articles for article (PubMed ID: 19601489)

  • 1. The issue of corrosion in dental implants: a review.
    Olmedo DG; Tasat DR; Duffó G; Guglielmotti MB; Cabrini RL
    Acta Odontol Latinoam; 2009; 22(1):3-9. PubMed ID: 19601489
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomaterial optimization in total disc arthroplasty.
    Hallab N; Link HD; McAfee PC
    Spine (Phila Pa 1976); 2003 Oct; 28(20):S139-52. PubMed ID: 14560185
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Corrosion behaviour of Ti-15Mo alloy for dental implant applications.
    Kumar S; Narayanan TS
    J Dent; 2008 Jul; 36(7):500-7. PubMed ID: 18468762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Titanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release.
    Morais LS; Serra GG; Muller CA; Andrade LR; Palermo EF; Elias CN; Meyers M
    Acta Biomater; 2007 May; 3(3):331-9. PubMed ID: 17257912
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Biodeterioration and corrosion of metallic implants and prostheses].
    López GD
    Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The electrochemical behavior of titanium and dental casting in modelling oral conditions].
    Pelsoczi-Kovács I; Kutsán G; Rauscher A; Fazekas A
    Fogorv Sz; 2005 Dec; 98(6):251-5. PubMed ID: 16468487
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An experimental model to study implant corrosion.
    Duffo G; Barreiro M; Olmedo D; Crosa M; Guglielmotti MB; Cabrini RL
    Acta Odontol Latinoam; 1999; 12(1):3-10. PubMed ID: 12905911
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.
    Gil FJ; Canedo R; Padrós A; Bañeres MV; Arano JM
    Biomed Mater Eng; 2003; 13(1):27-34. PubMed ID: 12652020
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Corrosion at the marginal gap of implant-supported suprastructures and implant failure.
    Guindy JS; Schiel H; Schmidli F; Wirz J
    Int J Oral Maxillofac Implants; 2004; 19(6):826-31. PubMed ID: 15623057
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion of implantable materials and aging of bone.
    Voitik AJ
    J Dent Technol; 1996 Jun; 13(5):24-32. PubMed ID: 9516274
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An overview of the corrosion aspect of dental implants (titanium and its alloys).
    Chaturvedi TP
    Indian J Dent Res; 2009; 20(1):91-8. PubMed ID: 19336868
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Are new TiNbZr alloys potential substitutes of the Ti6Al4V alloy for dental applications? An electrochemical corrosion study.
    Ribeiro AL; Hammer P; Vaz LG; Rocha LA
    Biomed Mater; 2013 Dec; 8(6):065005. PubMed ID: 24280708
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry].
    Hoffmann B; Kokott A; Shafranska O; Detsch R; Winter S; Eisenbarth E; Peters K; Breme J; Kirkpatrick CJ; Ziegler G
    Biomed Tech (Berl); 2005 Oct; 50(10):320-9. PubMed ID: 16300047
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.
    Krischak GD; Gebhard F; Mohr W; Krivan V; Ignatius A; Beck A; Wachter NJ; Reuter P; Arand M; Kinzl L; Claes LE
    Arch Orthop Trauma Surg; 2004 Mar; 124(2):104-13. PubMed ID: 14727127
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys for orthopedic implant applications.
    Samuel S; Nag S; Nasrazadani S; Ukirde V; El Bouanani M; Mohandas A; Nguyen K; Banerjee R
    J Biomed Mater Res A; 2010 Sep; 94(4):1251-6. PubMed ID: 20694992
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Corrosion and other electrochemical aspects of biomaterials.
    Bundy KJ
    Crit Rev Biomed Eng; 1994; 22(3-4):139-251. PubMed ID: 8598129
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of fluoride on the corrosion behavior of Ti and Ti6Al4V dental implants coupled with different superstructures.
    Anwar EM; Kheiralla LS; Tammam RH
    J Oral Implantol; 2011 Jun; 37(3):309-17. PubMed ID: 20545548
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Genotoxicity of corrosion eluates obtained from endosseous implants.
    Ribeiro DA; Matsumoto MA; Padovan LE; Marques ME; Salvadori DM
    Implant Dent; 2007 Mar; 16(1):101-9. PubMed ID: 17356376
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Local effect of titanium implant corrosion: an experimental study in rats.
    Olmedo DG; Duffó G; Cabrini RL; Guglielmotti MB
    Int J Oral Maxillofac Surg; 2008 Nov; 37(11):1032-8. PubMed ID: 18602796
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.