155 related articles for article (PubMed ID: 19602613)

  • 1. Dialytic phosphate removal: a modifiable measure of dialysis efficacy in automated peritoneal dialysis.
    Schmitt CP; Borzych D; Nau B; Wühl E; Zurowska A; Schaefer F
    Perit Dial Int; 2009; 29(4):465-71. PubMed ID: 19602613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Peritoneal phosphate removal varies by peritoneal dialysis regimen: an underestimated parameter of phosphate control.
    Botelho C; Rodrigues A; Oliveira JC; Cabrita A
    J Nephrol; 2013; 26(1):183-90. PubMed ID: 22460184
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Phosphate Removal by Peritoneal Dialysis: The Effect of Transporter Status and Peritoneal Dialysis Prescription.
    Courivaud C; Davenport A
    Perit Dial Int; 2016; 36(1):85-93. PubMed ID: 26224788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Peritoneal membrane phosphate transport status: a cornerstone in phosphate handling in peritoneal dialysis.
    Bernardo AP; Contesse SA; Bajo MA; Rodrigues A; Del Peso G; Ossorio M; Cabrita A; Selgas R
    Clin J Am Soc Nephrol; 2011 Mar; 6(3):591-7. PubMed ID: 21115631
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Peritoneal phosphate clearance is influenced by peritoneal dialysis modality, independent of peritoneal transport characteristics.
    Badve SV; Zimmerman DL; Knoll GA; Burns KD; McCormick BB
    Clin J Am Soc Nephrol; 2008 Nov; 3(6):1711-7. PubMed ID: 18815242
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Peritoneal equilibration test curves and adequacy of dialysis in children on automated peritoneal dialysis.
    Sliman GA; Klee KM; Gall-Holden B; Watkins SL
    Am J Kidney Dis; 1994 Nov; 24(5):813-8. PubMed ID: 7977324
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of individual ultrafiltration time (APEX) and purification phosphate time by peritoneal equilibration test: application to individual peritoneal dialysis modality prescription in children.
    Fischbach M; Lahlou A; Eyer D; Desprez P; Geisert J
    Perit Dial Int; 1996; 16 Suppl 1():S557-60. PubMed ID: 8728270
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of the dialysis fluid buffer on peritoneal membrane function in children.
    Schmitt CP; Nau B; Gemulla G; Bonzel KE; Hölttä T; Testa S; Fischbach M; John U; Kemper MJ; Sander A; Arbeiter K; Schaefer F
    Clin J Am Soc Nephrol; 2013 Jan; 8(1):108-15. PubMed ID: 23124784
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Phosphate clearance in peritoneal dialysis.
    Debowska M; Gomez R; Pinto J; Waniewski J; Lindholm B
    Sci Rep; 2020 Oct; 10(1):17504. PubMed ID: 33060672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of clearances on tidal peritoneal dialysis and intermittent peritoneal dialysis.
    Piraino B; Bender F; Bernardini J
    Perit Dial Int; 1994; 14(2):145-8. PubMed ID: 8043667
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Phosphate elimination in modalities of hemodialysis and peritoneal dialysis.
    Kuhlmann MK
    Blood Purif; 2010; 29(2):137-44. PubMed ID: 20093819
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Influencing factors in the control of phosphorus in peritoneal dialysis. Therapeutic options].
    Gallar P; Ortega O; Gutiérrez M; Muñoz M; Hilara L; Oliet A; Rodríguez I; Giménez E; Vigil A
    Nefrologia; 2000; 20(4):355-61. PubMed ID: 11039261
    [TBL] [Abstract][Full Text] [Related]  

  • 13. No significant differences in peritoneal fluid handling in children using PH-neutral or acidic solutions.
    Nourse P; van de Kar NC; Willems HL; Schröder CH
    Perit Dial Int; 2006; 26(5):587-92. PubMed ID: 16973515
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of intraperitoneal pressure, ultrafiltration and purification dwell times for individual peritoneal dialysis prescription in children.
    Fischbach M; Desprez P; Terzic J; Lahlou A; Mengus L; Geisert J
    Clin Nephrol; 1996 Jul; 46(1):14-6. PubMed ID: 8832143
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Peritoneal Phosphate Clearance: Determinants and Association With Mortality.
    Li J; Zhang W; Wang X; Sun N; Li L; Chang W
    Semin Dial; 2024; 37(3):259-268. PubMed ID: 38506151
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The beneficial influence on the effectiveness of automated peritoneal dialysis of varying the dwell time (short/long) and fill volume (small/large): a randomized controlled trial.
    Fischbach M; Issad B; Dubois V; Taamma R
    Perit Dial Int; 2011; 31(4):450-8. PubMed ID: 21454393
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous flow peritoneal dialysis: assessment of fluid and solute removal in a high-flow model of "fresh dialysate single pass".
    Freida P; Issad B
    Perit Dial Int; 2003; 23(4):348-55. PubMed ID: 12968842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The short PET in pediatrics.
    Warady BA; Jennings J
    Perit Dial Int; 2007; 27(4):441-5. PubMed ID: 17602153
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Phosphate clearance in peritoneal dialysis: automated PD compared with continuous ambulatory PD.
    Sawin DA; Himmele R; Diaz-Buxo JA
    Adv Perit Dial; 2012; 28():120-5. PubMed ID: 23311227
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of the effectiveness, safety, and biocompatibility of icodextrin in automated peritoneal dialysis. The Dextrin in APD in Amsterdam (DIANA) Group.
    Posthuma N; ter Wee PM; Donker AJ; Oe PL; Peers EM; Verbrugh HA
    Perit Dial Int; 2000; 20 Suppl 2():S106-13. PubMed ID: 10911654