BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 19602984)

  • 1. American Clinical MEG Society (ACMEGS) position statement: the value of magnetoencephalography (MEG)/magnetic source imaging (MSI) in noninvasive presurgical evaluation of patients with medically intractable localization-related epilepsy.
    Bagic A; Funke ME; Ebersole J;
    J Clin Neurophysiol; 2009 Aug; 26(4):290-3. PubMed ID: 19602984
    [No Abstract]   [Full Text] [Related]  

  • 2. Use of magnetoencephalography in the presurgical evaluation of epilepsy patients.
    Shibasaki H; Ikeda A; Nagamine T
    Clin Neurophysiol; 2007 Jul; 118(7):1438-48. PubMed ID: 17452007
    [TBL] [Abstract][Full Text] [Related]  

  • 3. American Clinical MEG Society (ACMEGS) Position Statement #2: The Value of Magnetoencephalography (MEG)/Magnetic Source Imaging (MSI) in Noninvasive Presurgical Mapping of Eloquent Cortices of Patients Preparing for Surgical Interventions.
    Bagić AI; Bowyer SM; Kirsch HE; Funke ME; Burgess RC;
    J Clin Neurophysiol; 2017 May; 34(3):189-195. PubMed ID: 28059855
    [No Abstract]   [Full Text] [Related]  

  • 4. [High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)].
    Gavaret M; Badier JM; Chauvel P
    Neurochirurgie; 2008 May; 54(3):185-90. PubMed ID: 18417162
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lateralizing language with magnetic source imaging: validation based on the Wada test.
    Doss RC; Zhang W; Risse GL; Dickens DL
    Epilepsia; 2009 Oct; 50(10):2242-8. PubMed ID: 19674060
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Utilization of magnetoencephalography results to obtain favourable outcomes in epilepsy surgery.
    Fischer MJ; Scheler G; Stefan H
    Brain; 2005 Jan; 128(Pt 1):153-7. PubMed ID: 15563514
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comment: A systematic review on MEG and its use in the presurgical evaluation of localization-related epilepsy.
    Fischer MJ; Rampp S; Scheler G; Stefan H
    Epilepsy Res; 2008 Dec; 82(2-3):238-9; author reply 240-1. PubMed ID: 18789653
    [No Abstract]   [Full Text] [Related]  

  • 8. Commentary on Lau et al., 2008. A systematic review on MEG and its use in the presurgical evaluation of localization-related epilepsy.
    Lewine JD
    Epilepsy Res; 2008 Dec; 82(2-3):235-6; author reply 240-1. PubMed ID: 18976885
    [No Abstract]   [Full Text] [Related]  

  • 9. A response to the article of Lau et al. "A systematic review on MEG and its use in the presurgical evaluation of localization related epilepsy", Epilepsy Research 2008;79(May (2-3)):97-104.
    Papanicolaou AC; Castillo E; Pataraia E; Wheless J; Breier J; Simos P
    Epilepsy Res; 2008 Dec; 82(2-3):237; author reply 240-1. PubMed ID: 18824327
    [No Abstract]   [Full Text] [Related]  

  • 10. Contribution of magnetic source imaging to the presurgical work-up of patients with refractory partial epilepsy.
    De Tiège X; Op de Beeck M; Bourguignon M; Legros B; Carette E; Vonck K; Boon P; Baleriaux D; Goldman S; Van Bogaert P
    JBR-BTR; 2008; 91(6):249-53. PubMed ID: 19202999
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Magnetic source imaging versus intracranial electroencephalogram in epilepsy surgery: a prospective study.
    Knowlton RC; Elgavish R; Howell J; Blount J; Burneo JG; Faught E; Kankirawatana P; Riley K; Morawetz R; Worthington J; Kuzniecky RI
    Ann Neurol; 2006 May; 59(5):835-42. PubMed ID: 16634031
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lobar localization information in epilepsy patients: MEG--a useful tool in routine presurgical diagnosis.
    Paulini A; Fischer M; Rampp S; Scheler G; Hopfengärtner R; Kaltenhäuser M; Dörfler A; Buchfelder M; Stefan H
    Epilepsy Res; 2007 Sep; 76(2-3):124-30. PubMed ID: 17719204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Magnetoencephalography in presurgical epilepsy diagnosis.
    Rampp S; Stefan H
    Expert Rev Med Devices; 2007 May; 4(3):335-47. PubMed ID: 17488228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Magnetoencephalography in neurosurgery.
    Mäkelä JP; Forss N; Jääskeläinen J; Kirveskari E; Korvenoja A; Paetau R
    Neurosurgery; 2006 Sep; 59(3):493-510; discussion 510-1. PubMed ID: 16955031
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Localization of epileptic foci in children with intractable epilepsy secondary to multiple cortical tubers by using synthetic aperture magnetometry kurtosis.
    Sugiyama I; Imai K; Yamaguchi Y; Ochi A; Akizuki Y; Go C; Akiyama T; Snead OC; Rutka JT; Drake JM; Widjaja E; Chuang SH; Cheyne D; Otsubo H
    J Neurosurg Pediatr; 2009 Dec; 4(6):515-22. PubMed ID: 19951036
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A systematic review on MEG and its use in the presurgical evaluation of localization-related epilepsy.
    Lau M; Yam D; Burneo JG
    Epilepsy Res; 2008 May; 79(2-3):97-104. PubMed ID: 18353615
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [New developments in clinical neurophysiology: magnetoencephalography. Contributions of magnetoencephalography to the study of epilepsy].
    Parra J; Velis DN
    Rev Neurol; 2000 Feb 16-29; 30(4):364-70. PubMed ID: 10789148
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetoencephalography adds to the surgical evaluation process.
    Stefan H; Rampp S; Knowlton RC
    Epilepsy Behav; 2011 Feb; 20(2):172-7. PubMed ID: 20934391
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Magnetic source imaging versus intracranial electroencephalogram: Neocortical versus temporolimbic epilepsy surgery.
    Wennberg R
    Ann Neurol; 2006 Aug; 60(2):271. PubMed ID: 16862587
    [No Abstract]   [Full Text] [Related]  

  • 20. Magnetic source imaging.
    Stefan H
    Rev Neurol (Paris); 2009 Oct; 165(10):742-5. PubMed ID: 19733871
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.