BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 19610312)

  • 1. Influence of phantom material and dimensions on experimental 192Ir dosimetry.
    Carlsson Tedgren A; Carlsson GA
    Med Phys; 2009 Jun; 36(6):2228-35. PubMed ID: 19610312
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources.
    Antonovic L; Gustafsson H; Carlsson GA; Carlsson Tedgren A
    Med Phys; 2009 Jun; 36(6):2236-47. PubMed ID: 19610313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo-based beam quality and phantom scatter corrections for solid-state detectors in 60Co and 192Ir brachytherapy dosimetry.
    Subhalaxmi M; Selvam TP
    J Appl Clin Med Phys; 2014 Nov; 15(6):4907. PubMed ID: 25493516
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
    Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Water equivalent phantom materials for ¹⁹²Ir brachytherapy.
    Schoenfeld AA; Harder D; Poppe B; Chofor N
    Phys Med Biol; 2015 Dec; 60(24):9403-20. PubMed ID: 26579946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The collapsed cone algorithm for (192)Ir dosimetry using phantom-size adaptive multiple-scatter point kernels.
    Tedgren ÅC; Plamondon M; Beaulieu L
    Phys Med Biol; 2015 Jul; 60(13):5313-23. PubMed ID: 26108232
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Phantom size in brachytherapy source dosimetric studies.
    Pérez-Calatayud J; Granero D; Ballester F
    Med Phys; 2004 Jul; 31(7):2075-81. PubMed ID: 15305460
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
    Chofor N; Harder D; Selbach HJ; Poppe B
    Z Med Phys; 2016 Sep; 26(3):238-50. PubMed ID: 26387927
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of water-mimicking solid phantom materials for use in HDR and LDR brachytherapy dosimetry.
    Schoenfeld AA; Thieben M; Harder D; Poppe B; Chofor N
    Phys Med Biol; 2017 Nov; 62(24):N561-N572. PubMed ID: 29072195
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP; Sahoo S; Vishwakarma RS
    Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
    Austerlitz C; Campos CA
    Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy.
    Poon E; Verhaegen F
    Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source.
    Karaiskos P; Angelopoulos A; Sakelliou L; Sandilos P; Antypas C; Vlachos L; Koutsouveli E
    Med Phys; 1998 Oct; 25(10):1975-84. PubMed ID: 9800706
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
    Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
    Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric characterization of round HDR 192Ir accuboost applicators for breast brachytherapy.
    Rivard MJ; Melhus CS; Wazer DE; Bricault RJ
    Med Phys; 2009 Nov; 36(11):5027-32. PubMed ID: 19994513
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo characterization of high atomic number inorganic scintillators for in vivo dosimetry in
    Kaveckyte V; Jørgensen EB; Kertzscher G; Johansen JG; Carlsson Tedgren Å
    Med Phys; 2022 Jul; 49(7):4715-4730. PubMed ID: 35443079
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources.
    Baltas D; Geramani K; Ioannidis GT; Hierholz K; Rogge B; Kolotas C; Müller-Sievers K; Milickovic N; Kober B; Zamboglou N
    Int J Radiat Oncol Biol Phys; 1999 Feb; 43(3):653-61. PubMed ID: 10078653
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.