765 related articles for article (PubMed ID: 19610319)
1. Inference of the optimal pretarget electron beam parameters in a Monte Carlo virtual linac model through simulated annealing.
Bush K; Zavgorodni S; Beckham W
Med Phys; 2009 Jun; 36(6):2309-19. PubMed ID: 19610319
[TBL] [Abstract][Full Text] [Related]
2. Sci-Fri AM: YIS-03: Simulated annealing optimization of the pre-target electron beam in Monte Carlo virtual linac models.
Bush K; Zavgorodni S; Beckham W
Med Phys; 2008 Jul; 35(7Part3):3410. PubMed ID: 28512888
[TBL] [Abstract][Full Text] [Related]
3. Monte carlo electron source model validation for an Elekta Precise linac.
Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
[TBL] [Abstract][Full Text] [Related]
4. Determination of the initial beam parameters in Monte Carlo linac simulation.
Aljarrah K; Sharp GC; Neicu T; Jiang SB
Med Phys; 2006 Apr; 33(4):850-8. PubMed ID: 16696460
[TBL] [Abstract][Full Text] [Related]
5. Characteristics of elliptical sources in BEAMnrc Monte Carlo system: implementation and application.
Kim S
Med Phys; 2009 Apr; 36(4):1046-52. PubMed ID: 19472609
[TBL] [Abstract][Full Text] [Related]
6. Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set.
Keall PJ; Siebers JV; Libby B; Mohan R
Med Phys; 2003 Apr; 30(4):574-82. PubMed ID: 12722809
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode.
Feng Z; Yue H; Zhang Y; Wu H; Cheng J; Su X
Radiat Oncol; 2016 Feb; 11():30. PubMed ID: 26921246
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of a medical linear accelerator for radiotherapy use.
Serrano B; Hachem A; Franchisseur E; Hérault J; Marcié S; Costa A; Bensadoun RJ; Barthe J; Gérard JP
Radiat Prot Dosimetry; 2006; 119(1-4):506-9. PubMed ID: 16644964
[TBL] [Abstract][Full Text] [Related]
9. The use of an extra-focal electron source to model collimator-scattered electrons using the pencil-beam redefinition algorithm.
Boyd RA; Hogstrom KR; White RA; Antolak JA
Med Phys; 2002 Nov; 29(11):2571-83. PubMed ID: 12462724
[TBL] [Abstract][Full Text] [Related]
10. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams.
Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N
Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo linear accelerator simulation of megavoltage photon beams: independent determination of initial beam parameters.
Almberg SS; Frengen J; Kylling A; Lindmo T
Med Phys; 2012 Jan; 39(1):40-7. PubMed ID: 22225273
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beam.
Borges C; Zarza-Moreno M; Heath E; Teixeira N; Vaz P
Med Phys; 2012 Jan; 39(1):415-23. PubMed ID: 22225311
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
Almberg SS; Frengen J; Lindmo T
Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
[TBL] [Abstract][Full Text] [Related]
14. Experimental determination of electron source parameters for accurate Monte Carlo calculation of large field electron therapy.
Huang VW; Seuntjens J; Devic S; Verhaegen F
Phys Med Biol; 2005 Mar; 50(5):779-86. PubMed ID: 15798254
[TBL] [Abstract][Full Text] [Related]
15. Modeling the truebeam linac using a CAD to Geant4 geometry implementation: dose and IAEA-compliant phase space calculations.
Constantin M; Perl J; LoSasso T; Salop A; Whittum D; Narula A; Svatos M; Keall PJ
Med Phys; 2011 Jul; 38(7):4018-24. PubMed ID: 21858999
[TBL] [Abstract][Full Text] [Related]
16. Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18MV photon beam: Determination of initial electron beam parameters.
Najafzadeh M; Hoseini-Ghafarokhi M; Bolagh RSM; Haghparast M; Zarifi S; Nickfarjam A; Farhood B; Chow JCL
J Xray Sci Technol; 2019; 27(6):1047-1070. PubMed ID: 31498147
[TBL] [Abstract][Full Text] [Related]
17. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
18. Influence of initial electron beam characteristics on monte carlo calculated absorbed dose distributions for linear accelerator electron beams.
Björk P; Knöös T; Nilsson P
Phys Med Biol; 2002 Nov; 47(22):4019-41. PubMed ID: 12476980
[TBL] [Abstract][Full Text] [Related]
19. DeepBeam: a machine learning framework for tuning the primary electron beam of the PRIMO Monte Carlo software.
Tabor Z; Kabat D; Waligórski MPR
Radiat Oncol; 2021 Jun; 16(1):124. PubMed ID: 34187495
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.
Bednarz B; Xu XG
Phys Med Biol; 2009 Feb; 54(4):N43-57. PubMed ID: 19141879
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]