134 related articles for article (PubMed ID: 19615928)

  • 1. [Quality control of a kV cone beam computed tomography imaging system].
    Marguet M; Bodez V
    Cancer Radiother; 2009 Sep; 13(5):345-52. PubMed ID: 19615928
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy.
    Bissonnette JP; Moseley D; White E; Sharpe M; Purdie T; Jaffray DA
    Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S57-61. PubMed ID: 18406939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Quality control of megavoltage cone beam CT imaging system].
    Isambert A; Ferreira IH; Nicula LE; Bonniaud G; Lefkopoulos D
    Cancer Radiother; 2008 Dec; 12(8):781-7. PubMed ID: 18691926
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator.
    Saw CB; Yang Y; Li F; Yue NJ; Ding C; Komanduri K; Huq S; Heron DE
    Med Dosim; 2007; 32(2):80-5. PubMed ID: 17472886
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of field-of-view and patient size on CT numbers from cone-beam computed tomography.
    Seet KY; Barghi A; Yartsev S; Van Dyk J
    Phys Med Biol; 2009 Oct; 54(20):6251-62. PubMed ID: 19794246
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Investigation on the 3 D geometric accuracy and on the image quality (MTF, SNR and NPS) of volume tomography units (CT, CBCT and DVT)].
    Blendl C; Fiebich M; Voigt JM; Selbach M; Uphoff C
    Rofo; 2012 Jan; 184(1):24-31. PubMed ID: 22076796
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An evaluation of the stability of image-quality parameters of Varian on-board imaging (OBI) and EPID imaging systems.
    Stanley DN; Papanikolaou N; Gutierrez AN
    J Appl Clin Med Phys; 2015 Mar; 16(2):5088. PubMed ID: 26103178
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A quantitative image quality comparison of four different image guided radiotherapy devices.
    Stützel J; Oelfke U; Nill S
    Radiother Oncol; 2008 Jan; 86(1):20-4. PubMed ID: 18031854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.
    Sykes JR; Lindsay R; Dean CJ; Brettle DS; Magee DR; Thwaites DI
    Phys Med Biol; 2008 Oct; 53(19):5275-93. PubMed ID: 18758000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the truebeam machine performance check (MPC): OBI X-ray tube alignment procedure.
    Barnes MP; Pomare D; Menk FW; Moraro B; Greer PB
    J Appl Clin Med Phys; 2018 Nov; 19(6):68-78. PubMed ID: 30178521
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Elekta Precise Table characteristics of IGRT remote table positioning.
    Riis HL; Zimmermann SJ
    Acta Oncol; 2009; 48(2):267-70. PubMed ID: 18756401
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems.
    Du LY; Umoh J; Nikolov HN; Pollmann SI; Lee TY; Holdsworth DW
    Phys Med Biol; 2007 Dec; 52(23):7087-108. PubMed ID: 18029995
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the effects of sagging shifts on isocenter accuracy and image quality of cone-beam CT from kV on-board imagers.
    Ali I; Ahmad S
    J Appl Clin Med Phys; 2009 Jul; 10(3):180-194. PubMed ID: 19692976
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A quality assurance program for image quality of cone-beam CT guidance in radiation therapy.
    Bissonnette JP; Moseley DJ; Jaffray DA
    Med Phys; 2008 May; 35(5):1807-15. PubMed ID: 18561655
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A feasibility study on the use of digital tomosynthesis with individually-acquired megavoltage portal images for target localization.
    Sarkar V; Shi C; Rassiah-Szegedi P; Eng T; Diaz A; Papanikolaou N
    J BUON; 2009; 14(1):103-8. PubMed ID: 19365878
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Absorbed dose and image quality of Varian TrueBeam CBCT compared with OBI CBCT.
    Kawahara D; Ozawa S; Nakashima T; Suzuki T; Tsuneda M; Tanaka S; Ohno Y; Murakami Y; Nagata Y
    Phys Med; 2016 Dec; 32(12):1628-1633. PubMed ID: 27923551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multipurpose quality assurance phantom for the small animal radiation research platform (SARRP).
    Ngwa W; Tsiamas P; Zygmanski P; Makrigiorgos GM; Berbeco RI
    Phys Med Biol; 2012 May; 57(9):2575-86. PubMed ID: 22491061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator.
    Sharpe MB; Moseley DJ; Purdie TG; Islam M; Siewerdsen JH; Jaffray DA
    Med Phys; 2006 Jan; 33(1):136-44. PubMed ID: 16485420
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cyberknife image-guided delivery and quality assurance.
    Dieterich S; Pawlicki T
    Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S126-30. PubMed ID: 18406910
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system.
    Pang G; Bani-Hashemi A; Au P; O'Brien PF; Rowlands JA; Morton G; Lim T; Cheung P; Loblaw A
    Phys Med Biol; 2008 Feb; 53(4):999-1013. PubMed ID: 18263954
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.