BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 19616909)

  • 21. The GGO lesions detected by computer-aided detection system on chest MDCT images.
    Lee JW; Jeong JW; Lee S; Yoo DS; Kim S
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1983-5. PubMed ID: 17945689
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A retrospective study of chest tomosynthesis as a tool for optimizing the use of computed tomography resources and reducing patient radiation exposure.
    Johnsson ÅA; Vikgren J; Båth M
    Acad Radiol; 2014 Nov; 21(11):1427-33. PubMed ID: 25097012
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.
    Choo JY; Lee KY; Yu A; Kim JH; Lee SH; Choi JW; Kang EY; Oh YW
    Eur Radiol; 2016 Sep; 26(9):3147-54. PubMed ID: 26662264
    [TBL] [Abstract][Full Text] [Related]  

  • 24. EFFECT OF RADIATION DOSE LEVEL ON ACCURACY AND PRECISION OF MANUAL SIZE MEASUREMENTS IN CHEST TOMOSYNTHESIS EVALUATED USING SIMULATED PULMONARY NODULES.
    Söderman C; Johnsson ÅA; Vikgren J; Norrlund RR; Molnar D; Svalkvist A; Månsson LG; Båth M
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):188-98. PubMed ID: 26994093
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detection of Pulmonary Nodule Growth with Chest Tomosynthesis: A Human Observer Study Using Simulated Nodules.
    Söderman C; Johnsson ÅA; Vikgren J; Norrlund RR; Molnar D; Mirzai M; Svalkvist A; Månsson LG; Båth M
    Acad Radiol; 2019 Apr; 26(4):508-518. PubMed ID: 29903641
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Quantitative nodule detection in low dose chest CT scans: new template modeling and evaluation for CAD system design.
    Farag AA; El-Baz A; Gimelfarb G; El-Ghar MA; Eldiasty T
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):720-8. PubMed ID: 16685910
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Development of a digital chest phantom for studies on energy subtraction techniques].
    Hayashi N; Taniguchi A; Noto K; Shimosegawa M; Ogura T; Doi K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Mar; 70(3):191-8. PubMed ID: 24647055
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted).
    Ebner L; Bütikofer Y; Ott D; Huber A; Landau J; Roos JE; Heverhagen JT; Christe A
    AJR Am J Roentgenol; 2015 Apr; 204(4):727-35. PubMed ID: 25794062
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging.
    Godfrey DJ; McAdams HP; Dobbins JT
    Med Phys; 2006 Mar; 33(3):655-67. PubMed ID: 16878569
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease.
    Lee G; Jeong YJ; Kim KI; Song JW; Kang DM; Kim YD; Lee JW
    Clin Radiol; 2013 Apr; 68(4):376-82. PubMed ID: 23177084
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Detection of lung nodules. New opportunities in chest radiography].
    Pötter-Lang S; Schalekamp S; Schaefer-Prokop C; Uffmann M
    Radiologe; 2014 May; 54(5):455-61. PubMed ID: 24789046
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Nodule detection in digital chest radiography: effect of system noise.
    Håkansson M; Båth M; Börjesson S; Kheddache S; Johnsson AA; Månsson LG
    Radiat Prot Dosimetry; 2005; 114(1-3):97-101. PubMed ID: 15933088
    [TBL] [Abstract][Full Text] [Related]  

  • 33. INFLUENCE OF THE IN-PLANE ARTEFACT IN CHEST TOMOSYNTHESIS ON PULMONARY NODULE SIZE MEASUREMENTS.
    Söderman C; Johnsson ÅA; Vikgren J; Norrlund RR; Molnar D; Svalkvist A; Månsson LG; Båth M
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):199-203. PubMed ID: 26769904
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules.
    Yamada Y; Shiomi E; Hashimoto M; Abe T; Matsusako M; Saida Y; Ogawa K
    Radiology; 2018 Apr; 287(1):333-339. PubMed ID: 29206596
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Volumetric measurement pulmonary ground-glass opacity nodules with multi-detector CT: effect of various tube current on measurement accuracy--a chest CT phantom study.
    Linning E; Daqing M
    Acad Radiol; 2009 Aug; 16(8):934-9. PubMed ID: 19409818
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A dual-view digital tomosynthesis imaging technique for improved chest imaging.
    Zhong Y; Lai CJ; Wang T; Shaw CC
    Med Phys; 2015 Sep; 42(9):5238-51. PubMed ID: 26328973
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Lung nodule detection in pediatric chest CT: quantitative relationship between image quality and radiologist performance.
    Li X; Samei E; Barnhart HX; Gaca AM; Hollingsworth CL; Maxfield CM; Carrico CW; Colsher JG; Frush DP
    Med Phys; 2011 May; 38(5):2609-18. PubMed ID: 21776798
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection.
    Kim SM; Chung MJ; Lee KS; Kang H; Song IY; Lee EJ; Hwang HS
    Acta Radiol; 2013 Jul; 54(6):634-9. PubMed ID: 23528563
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of clinical experience of chest tomosynthesis on detection of pulmonary nodules.
    Zachrisson S; Vikgren J; Svalkvist A; Johnsson AA; Boijsen M; Flinck A; Månsson LG; Kheddache S; Båth M
    Acta Radiol; 2009 Oct; 50(8):884-91. PubMed ID: 19639475
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13mSv.
    Messerli M; Kluckert T; Knitel M; Rengier F; Warschkow R; Alkadhi H; Leschka S; Wildermuth S; Bauer RW
    Eur J Radiol; 2016 Dec; 85(12):2217-2224. PubMed ID: 27842670
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.