These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 19640638)

  • 1. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry.
    Shamsipur M; Dezaki AS; Akhond M; Sharghi H; Paziraee Z; Alizadeh K
    J Hazard Mater; 2009 Dec; 172(2-3):566-73. PubMed ID: 19640638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel flow injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion.
    Shamsipur M; Mizani F; Mousavi MF; Alizadeh N; Alizadeh K; Eshghi H; Karami H
    Anal Chim Acta; 2007 Apr; 589(1):22-32. PubMed ID: 17397648
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lead-selective poly(vinyl chloride) electrodes based on some synthesized benzo-substituted macrocyclic diamides.
    Kazemi SY; Shamsipur M; Sharghi H
    J Hazard Mater; 2009 Dec; 172(1):68-73. PubMed ID: 19643538
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Highly selective potentiometric determination of mercury(II) ions using 1-furan-2-yl-4-(4-nitrophenyl)-2-phenyl-5H-imidazole-3-oxide based membrane electrodes.
    Mahajan RK; Puri RK; Marwaha A; Kaur I; Mahajan MP
    J Hazard Mater; 2009 Aug; 167(1-3):237-43. PubMed ID: 19185990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands.
    Singh AK; Singh P; Banerjee S; Mehtab S
    Anal Chim Acta; 2009 Feb; 633(1):109-18. PubMed ID: 19110124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fabrication of novel coated pyrolytic graphite electrodes for the selective nano-level monitoring of Cd²⁺ ions in biological and environmental samples using polymeric membrane of newly synthesized macrocycle.
    Sahani MK; Singh AK; Jain AK; Upadhyay A; Kumar A; Singh UP; Narang S
    Anal Chim Acta; 2015 Feb; 860():51-60. PubMed ID: 25682247
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A polyvinylchloride-based cadmium ion-selective electrode using [Mo₂(OAc)₂(H₂-calix[4]arene)] as an electroactive material.
    Tyagi S; Agarwal H; Ikram S
    Water Sci Technol; 2010; 62(11):2510-8. PubMed ID: 21099036
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine.
    Mizani F; Salmanzadeh Ardabili S; Ganjaliab MR; Faridbod F; Payehghadr M; Azmoodeh M
    Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():861-868. PubMed ID: 25687018
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle.
    Singh AK; Singh P
    Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PVC membrane and coated graphite potentiometric sensors based on Et4todit for selective determination of samarium(III).
    Shamsipur M; Hosseini M; Alizadeh K; Talebpour Z; Mousavi MF; Ganjali MR; Arca M; Lippolis V
    Anal Chem; 2003 Nov; 75(21):5680-6. PubMed ID: 14588005
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel PVC-membrane optical sensor for highly sensitive and selective determination of UO2(2+) ion based on a recently synthesized benzo-substituted macrocyclic diamide and dibenzoylmethane.
    Shamsipur M; Zargoosh K; Mizani F; Eshghi H; Rostami F
    Spectrochim Acta A Mol Biomol Spectrosc; 2010 Sep; 77(1):319-23. PubMed ID: 20635469
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores.
    Singh AK; Gupta VK; Gupta B
    Anal Chim Acta; 2007 Feb; 585(1):171-8. PubMed ID: 17386662
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases.
    Gupta VK; Al Khayat M; Singh AK; Pal MK
    Anal Chim Acta; 2009 Feb; 634(1):36-43. PubMed ID: 19154807
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A fast response cadmium-selective polymeric membrane electrode based on N,N'-(4-methyl-1,2-phenylene)diquinoline-2-carboxamide as a new neutral carrier.
    Rezaei B; Meghdadi S; Zarandi RF
    J Hazard Mater; 2008 May; 153(1-2):179-86. PubMed ID: 17881121
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nano-level monitoring of Yb(III) by fabrication of coated graphite electrode based on newly synthesized hexaaza macrocyclic ligand.
    Singh AK; Singh P
    Anal Chim Acta; 2009 Jun; 643(1-2):74-82. PubMed ID: 19446066
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow Injection Potentiometric Determination of Cd2+ Ions Using a Coated Graphite Plasticized PVC-Membrane Electrode Based on 1, 3-Bis(2-cyanobenzene)triazene.
    Shamsipur M; Sahari S; Payehghadr M; Alizadeh K
    Acta Chim Slov; 2011 Sep; 58(3):555-62. PubMed ID: 24062116
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Potentiometric polymeric membrane electrodes for mercury detection using calixarene ionophores.
    Tyagi S; Agarwal H; Ikram S
    Water Sci Technol; 2010; 61(3):693-704. PubMed ID: 20150706
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
    Singh AK; Saxena P; Mehtab S; Gupta B
    Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode.
    Singh AK; Singh P; Bhattacharjee G
    Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
    Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
    Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.