97 related articles for article (PubMed ID: 19640758)
1. [Dose delivered to the patient by megavoltage cone beam computed tomography imaging].
Isambert A; Ferreira IH; Bossi A; Beaudré A; Nicula LE; Lefkopoulos D
Cancer Radiother; 2009 Sep; 13(5):358-64. PubMed ID: 19640758
[TBL] [Abstract][Full Text] [Related]
2. Patient dose considerations for routine megavoltage cone-beam CT imaging.
Morin O; Gillis A; Descovich M; Chen J; Aubin M; Aubry JF; Chen H; Gottschalk AR; Xia P; Pouliot J
Med Phys; 2007 May; 34(5):1819-27. PubMed ID: 17555263
[TBL] [Abstract][Full Text] [Related]
3. Megavoltage cone beam computed tomography dose and the necessity of reoptimization for imaging dose-integrated intensity-modulated radiotherapy for prostate cancer.
Akino Y; Koizumi M; Sumida I; Takahashi Y; Ogata T; Ota S; Isohashi F; Konishi K; Yoshioka Y
Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1715-22. PubMed ID: 21620584
[TBL] [Abstract][Full Text] [Related]
4. Estimation of rectal dose using daily megavoltage cone-beam computed tomography and deformable image registration.
Akino Y; Yoshioka Y; Fukuda S; Maruoka S; Takahashi Y; Yagi M; Mizuno H; Isohashi F; Ogawa K
Int J Radiat Oncol Biol Phys; 2013 Nov; 87(3):602-8. PubMed ID: 24074934
[TBL] [Abstract][Full Text] [Related]
5. Testicular doses in image-guided radiotherapy of prostate cancer.
Deng J; Chen Z; Yu JB; Roberts KB; Peschel RE; Nath R
Int J Radiat Oncol Biol Phys; 2012 Jan; 82(1):e39-47. PubMed ID: 21489702
[TBL] [Abstract][Full Text] [Related]
6. Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes.
Aubry JF; Cheung J; Morin O; Gottschalk A; Beaulieu L; Pouliot J
J Appl Clin Med Phys; 2009 Jan; 10(1):33-42. PubMed ID: 19223832
[TBL] [Abstract][Full Text] [Related]
7. Experimental evaluation of actual delivered dose using mega-voltage cone-beam CT and direct point dose measurement.
Matsubara K; Kohno R; Nishioka S; Shibuya T; Ariji T; Akimoto T; Saitoh H
Med Dosim; 2013; 38(2):153-9. PubMed ID: 23266165
[TBL] [Abstract][Full Text] [Related]
8. Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification.
Sidhu K; Ford EC; Spirou S; Yorke E; Chang J; Mueller K; Todor D; Rosenzweig K; Mageras G; Chui C; Ling CC; Amols H
Int J Radiat Oncol Biol Phys; 2003 Mar; 55(3):757-67. PubMed ID: 12573763
[TBL] [Abstract][Full Text] [Related]
9. Image quality improvement in megavoltage cone beam CT using an imaging beam line and a sintered pixelated array system.
Breitbach EK; Maltz JS; Gangadharan B; Bani-Hashemi A; Anderson CM; Bhatia SK; Stiles J; Edwards DS; Flynn RT
Med Phys; 2011 Nov; 38(11):5969-79. PubMed ID: 22047361
[TBL] [Abstract][Full Text] [Related]
10. Patient-specific three-dimensional concomitant dose from cone beam computed tomography exposure in image-guided radiotherapy.
Spezi E; Downes P; Jarvis R; Radu E; Staffurth J
Int J Radiat Oncol Biol Phys; 2012 May; 83(1):419-26. PubMed ID: 22027261
[TBL] [Abstract][Full Text] [Related]
11. Low-dose megavoltage cone-beam computed tomography using a novel multi-layer imager (MLI).
Myronakis M; Huber P; Lehmann M; Fueglistaller R; Jacobson M; Hu YH; Baturin P; Wang A; Shi M; Harris T; Morf D; Berbeco R
Med Phys; 2020 Apr; 47(4):1827-1835. PubMed ID: 31930516
[TBL] [Abstract][Full Text] [Related]
12. Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon target.
Faddegon BA; Wu V; Pouliot J; Gangadharan B; Bani-Hashemi A
Med Phys; 2008 Dec; 35(12):5777-86. PubMed ID: 19175135
[TBL] [Abstract][Full Text] [Related]
13. 3D in vivo dosimetry using megavoltage cone-beam CT and EPID dosimetry.
van Elmpt W; Nijsten S; Petit S; Mijnheer B; Lambin P; Dekker A
Int J Radiat Oncol Biol Phys; 2009 Apr; 73(5):1580-7. PubMed ID: 19306755
[TBL] [Abstract][Full Text] [Related]
14. Analysis of interfraction prostate motion using megavoltage cone beam computed tomography.
Bylund KC; Bayouth JE; Smith MC; Hass AC; Bhatia SK; Buatti JM
Int J Radiat Oncol Biol Phys; 2008 Nov; 72(3):949-56. PubMed ID: 19014783
[TBL] [Abstract][Full Text] [Related]
15. Dose recalculation and the Dose-Guided Radiation Therapy (DGRT) process using megavoltage cone-beam CT.
Cheung J; Aubry JF; Yom SS; Gottschalk AR; Celi JC; Pouliot J
Int J Radiat Oncol Biol Phys; 2009 Jun; 74(2):583-92. PubMed ID: 19345518
[TBL] [Abstract][Full Text] [Related]
16. Low-dose 2.5 MV cone-beam computed tomography with thick CsI flat-panel imager.
Tang G; Moussot C; Morf D; Seppi E; Amols H
J Appl Clin Med Phys; 2016 Jul; 17(4):235-245. PubMed ID: 27455493
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric characterization and application of an imaging beam line with a carbon electron target for megavoltage cone beam computed tomography.
Flynn RT; Hartmann J; Bani-Hashemi A; Nixon E; Alfredo R; Siochi C; Pennington EC; Bayouth JE
Med Phys; 2009 Jun; 36(6):2181-92. PubMed ID: 19610307
[TBL] [Abstract][Full Text] [Related]
18. Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy.
Mock U; Bogner J; Georg D; Auberger T; Pötter R
Strahlenther Onkol; 2005 Jul; 181(7):448-55. PubMed ID: 15995838
[TBL] [Abstract][Full Text] [Related]
19. Potential role of intensity modulated proton beams in prostate cancer radiotherapy.
Cella L; Lomax A; Miralbell R
Int J Radiat Oncol Biol Phys; 2001 Jan; 49(1):217-23. PubMed ID: 11163518
[TBL] [Abstract][Full Text] [Related]
20. Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CT.
Walter C; Boda-Heggemann J; Wertz H; Loeb I; Rahn A; Lohr F; Wenz F
Radiother Oncol; 2007 Dec; 85(3):418-23. PubMed ID: 18023491
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]