These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 19643471)

  • 1. Clinical fracture of cross-linked UHMWPE acetabular liners.
    Furmanski J; Anderson M; Bal S; Greenwald AS; Halley D; Penenberg B; Ries M; Pruitt L
    Biomaterials; 2009 Oct; 30(29):5572-82. PubMed ID: 19643471
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implant wear mechanisms--basic approach.
    Bhatt H; Goswami T
    Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
    Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
    Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE.
    Gomoll A; Wanich T; Bellare A
    J Orthop Res; 2002 Nov; 20(6):1152-6. PubMed ID: 12472222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retrieved highly crosslinked UHMWPE acetabular liners have similar wear damage as conventional UHMWPE.
    Schroder DT; Kelly NH; Wright TM; Parks ML
    Clin Orthop Relat Res; 2011 Feb; 469(2):387-94. PubMed ID: 20844998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly cross-linked vs conventional polyethylene: no differences in rim notching from micromotion on retrieved acetabular liners.
    Paterson NR; Teeter MG; Macdonald SJ; McCalden RW; Howard JL; Naudie DD
    J Arthroplasty; 2012 Oct; 27(9):1616-1621.e1. PubMed ID: 22608684
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of patient gait on the material properties of UHMWPE in hip replacements.
    Davey SM; Orr JF; Buchanan FJ; Nixon JR; Bennett D
    Biomaterials; 2005 Aug; 26(24):4993-5001. PubMed ID: 15769535
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of retrieved acetabular components of three polyethylene types.
    Salineros MJ; Crowninshield RD; Laurent M; Wimmer MA; Jacobs JJ
    Clin Orthop Relat Res; 2007 Dec; 465():140-9. PubMed ID: 17632415
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Review of the evolution of the cementless acetabular cup.
    Ries MD
    Orthopedics; 2008 Dec; 31(12 Suppl 2):. PubMed ID: 19298028
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Surface cross-linked UHMWPE can enable the use of larger femoral heads in total joints.
    Oral E; Neils AL; Lyons C; Fung M; Doshi B; Muratoglu OK
    J Orthop Res; 2013 Jan; 31(1):59-66. PubMed ID: 22847503
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator.
    Taddei P; Affatato S; Fagnano C; Toni A
    Biomacromolecules; 2006 Jun; 7(6):1912-20. PubMed ID: 16768414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The basis for a second-generation highly cross-linked UHMWPE.
    Dumbleton JH; D'Antonio JA; Manley MT; Capello WN; Wang A
    Clin Orthop Relat Res; 2006 Dec; 453():265-71. PubMed ID: 17016228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation.
    Ong KL; Rundell S; Liepins I; Laurent R; Markel D; Kurtz SM
    J Orthop Res; 2009 Nov; 27(11):1467-72. PubMed ID: 19489047
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fractures of a single design of highly cross-linked polyethylene acetabular liners: an analysis of voluntary reports to the United States Food and Drug Administration.
    Ast MP; John TK; Labbisiere A; Robador N; Valle AG
    J Arthroplasty; 2014 Jun; 29(6):1231-5. PubMed ID: 24444569
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of severely fractured glenoid components: clinical consequences of biomechanics, design, and materials selection on implant performance.
    Ansari F; Lee T; Malito L; Martin A; Gunther SB; Harmsen S; Norris TR; Ries M; Van Citters D; Pruitt L
    J Shoulder Elbow Surg; 2016 Jul; 25(7):1041-50. PubMed ID: 26775748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners.
    Wannomae KK; Christensen SD; Freiberg AA; Bhattacharyya S; Harris WH; Muratoglu OK
    Biomaterials; 2006 Mar; 27(9):1980-7. PubMed ID: 16271756
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator.
    D'Lima DD; Hermida JC; Chen PC; Colwell CW
    J Orthop Res; 2003 Sep; 21(5):761-6. PubMed ID: 12919860
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals.
    Wannomae KK; Bhattacharyya S; Freiberg A; Estok D; Harris WH; Muratoglu O
    J Arthroplasty; 2006 Oct; 21(7):1005-11. PubMed ID: 17027543
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.
    Oral E; Christensen SD; Malhi AS; Wannomae KK; Muratoglu OK
    J Arthroplasty; 2006 Jun; 21(4):580-91. PubMed ID: 16781413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Highly cross-linked polyethylene bearing surfaces in total hip arthroplasty.
    Atienza C; Maloney WJ
    J Surg Orthop Adv; 2008; 17(1):27-33. PubMed ID: 18284901
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.