These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
375 related articles for article (PubMed ID: 19652949)
21. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography. Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321 [TBL] [Abstract][Full Text] [Related]
22. Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation. Zhao Z; Wang W; Zhang Z; Xu M; Frerichs I; Wu J; Moeller K Physiol Meas; 2018 Mar; 39(3):034003. PubMed ID: 29431700 [TBL] [Abstract][Full Text] [Related]
23. The EIT-based global inhomogeneity index is highly correlated with regional lung opening in patients with acute respiratory distress syndrome. Zhao Z; Pulletz S; Frerichs I; Müller-Lisse U; Möller K BMC Res Notes; 2014 Feb; 7():82. PubMed ID: 24502320 [TBL] [Abstract][Full Text] [Related]
24. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial. Bikker IG; Preis C; Egal M; Bakker J; Gommers D Crit Care; 2011 Aug; 15(4):R193. PubMed ID: 21834953 [TBL] [Abstract][Full Text] [Related]
25. Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure. Frerichs I; Hahn G; Hellige G IEEE Trans Med Imaging; 1999 Sep; 18(9):764-73. PubMed ID: 10571381 [TBL] [Abstract][Full Text] [Related]
26. Integrated EIT system for functional lung ventilation imaging. Jang GY; Ayoub G; Kim YE; Oh TI; Chung CR; Suh GY; Woo EJ Biomed Eng Online; 2019 Jul; 18(1):83. PubMed ID: 31345220 [TBL] [Abstract][Full Text] [Related]
27. Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation: an observational study during the spontaneous breathing trial. Wisse JJ; Goos TG; Jonkman AH; Somhorst P; Reiss IKM; Endeman H; Gommers D Respir Res; 2024 Apr; 25(1):179. PubMed ID: 38664685 [TBL] [Abstract][Full Text] [Related]
28. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Meier T; Luepschen H; Karsten J; Leibecke T; Grossherr M; Gehring H; Leonhardt S Intensive Care Med; 2008 Mar; 34(3):543-50. PubMed ID: 17653529 [TBL] [Abstract][Full Text] [Related]
29. Tidal ventilation distribution during pressure-controlled ventilation and pressure support ventilation in post-cardiac surgery patients. Blankman P; VAN DER Kreeft SM; Gommers D Acta Anaesthesiol Scand; 2014 Sep; 58(8):997-1006. PubMed ID: 25039666 [TBL] [Abstract][Full Text] [Related]
30. Lung computed tomography density distribution in a porcine model of one-lung ventilation. Kozian A; Schilling T; Schütze H; Heres F; Hachenberg T; Hedenstierna G Br J Anaesth; 2009 Apr; 102(4):551-60. PubMed ID: 19224926 [TBL] [Abstract][Full Text] [Related]
31. Influence of tidal volume on ventilation inhomogeneity assessed by electrical impedance tomography during controlled mechanical ventilation. Becher T; Kott M; Schädler D; Vogt B; Meinel T; Weiler N; Frerichs I Physiol Meas; 2015 Jun; 36(6):1137-46. PubMed ID: 26007294 [TBL] [Abstract][Full Text] [Related]
32. Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography. Markhorst DG; Groeneveld AB; Heethaar RM; Zonneveld E; Van Genderingen HR J Med Eng Technol; 2009; 33(4):281-7. PubMed ID: 19384703 [TBL] [Abstract][Full Text] [Related]
33. Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study. Becher TH; Bui S; Zick G; Bläser D; Schädler D; Weiler N; Frerichs I Crit Care; 2014 Dec; 18(6):679. PubMed ID: 25492307 [TBL] [Abstract][Full Text] [Related]
34. Early individualized positive end-expiratory pressure guided by electrical impedance tomography in acute respiratory distress syndrome: a randomized controlled clinical trial. He H; Chi Y; Yang Y; Yuan S; Long Y; Zhao P; Frerichs I; Fu F; Möller K; Zhao Z Crit Care; 2021 Jun; 25(1):230. PubMed ID: 34193224 [TBL] [Abstract][Full Text] [Related]
35. Regional lung opening and closing pressures in patients with acute lung injury. Pulletz S; Adler A; Kott M; Elke G; Gawelczyk B; Schädler D; Zick G; Weiler N; Frerichs I J Crit Care; 2012 Jun; 27(3):323.e11-8. PubMed ID: 22033052 [TBL] [Abstract][Full Text] [Related]
36. Comparison of low and high positive end-expiratory pressure during low tidal volume ventilation in robotic gynaecological surgical patients using electrical impedance tomography: A randomised controlled trial. Chun EH; Baik HJ; Moon HS; Jeong K Eur J Anaesthesiol; 2019 Sep; 36(9):641-648. PubMed ID: 31306184 [TBL] [Abstract][Full Text] [Related]
37. Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? Frerichs I; Dargaville PA; Dudykevych T; Rimensberger PC Intensive Care Med; 2003 Dec; 29(12):2312-2316. PubMed ID: 14566457 [TBL] [Abstract][Full Text] [Related]
38. A lung area estimation method for analysis of ventilation inhomogeneity based on electrical impedance tomography. Zhao Z; Steinmann D; Müller-Zivkovic D; Martin J; Frerichs I; Guttmann J; Möller K J Xray Sci Technol; 2010; 18(2):171-82. PubMed ID: 20495244 [TBL] [Abstract][Full Text] [Related]
39. Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre. Dargaville PA; Rimensberger PC; Frerichs I Intensive Care Med; 2010 Nov; 36(11):1953-61. PubMed ID: 20689920 [TBL] [Abstract][Full Text] [Related]
40. Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing. Vogt B; Pulletz S; Elke G; Zhao Z; Zabel P; Weiler N; Frerichs I J Appl Physiol (1985); 2012 Oct; 113(7):1154-61. PubMed ID: 22898553 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]