435 related articles for article (PubMed ID: 19673206)
21. Impact of target-to-background ratio, target size, emission scan duration, and activity on physical figures of merit for a 3D LSO-based whole body PET/CT scanner.
Brambilla M; Matheoud R; Secco C; Sacchetti G; Comi S; Rudoni M; Carriero A; Inglese E
Med Phys; 2007 Oct; 34(10):3854-65. PubMed ID: 17985631
[TBL] [Abstract][Full Text] [Related]
22. 4D numerical observer for lesion detection in respiratory-gated PET.
Lorsakul A; Li Q; Trott CM; Hoog C; Petibon Y; Ouyang J; Laine AF; El Fakhri G
Med Phys; 2014 Oct; 41(10):102504. PubMed ID: 25281979
[TBL] [Abstract][Full Text] [Related]
23. The impact of iterative reconstruction protocol, signal-to-background ratio and background activity on measurement of PET spatial resolution.
Rezaei S; Ghafarian P; Bakhshayesh-Karam M; Uribe CF; Rahmim A; Sarkar S; Ay MR
Jpn J Radiol; 2020 Mar; 38(3):231-239. PubMed ID: 31894449
[TBL] [Abstract][Full Text] [Related]
24. Reliability of predicting image signal-to-noise ratio using noise equivalent count rate in PET imaging.
Chang T; Chang G; Clark JW; Diab RH; Rohren E; Mawlawi OR
Med Phys; 2012 Oct; 39(10):5891-900. PubMed ID: 23039628
[TBL] [Abstract][Full Text] [Related]
25. Reduction of emission time for [68Ga]Ga-PSMA PET/CT using the digital biograph vision: a phantom study.
Fragoso Costa P; Jentzen W; SÜßELBECK F; Fendler WP; Rischpler C; Herrmann K; Conti M; Kersting D; Weber M
Q J Nucl Med Mol Imaging; 2023 Mar; 67(1):57-68. PubMed ID: 34309334
[TBL] [Abstract][Full Text] [Related]
26. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
27. Adaptive Autoregressive Model for Reduction of Noise in SPECT.
Takalo R; Hytti H; Ihalainen H; Sohlberg A
Comput Math Methods Med; 2015; 2015():494691. PubMed ID: 26089966
[TBL] [Abstract][Full Text] [Related]
28. Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.
Lartizien C; Kinahan PE; Swensson R; Comtat C; Lin M; Villemagne V; Trébossen R
J Nucl Med; 2003 Feb; 44(2):276-90. PubMed ID: 12571221
[TBL] [Abstract][Full Text] [Related]
29. Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM).
Cheng JK; Matthews J; Sossi V; Anton-Rodriguez J; Salomon A; Boellaard R
Phys Med Biol; 2017 Aug; 62(16):6666-6687. PubMed ID: 28644152
[TBL] [Abstract][Full Text] [Related]
30. Optimization of PET/CT image quality using the GE 'Sharp IR' point-spread function reconstruction algorithm.
Vennart NJ; Bird N; Buscombe J; Cheow HK; Nowosinska E; Heard S
Nucl Med Commun; 2017 Jun; 38(6):471-479. PubMed ID: 28394818
[TBL] [Abstract][Full Text] [Related]
31. Quantitative and Qualitative Improvement of Low-Count [
Seo Y; Khalighi MM; Wangerin KA; Deller TW; Wang YH; Jivan S; Kohi MP; Aggarwal R; Flavell RR; Behr SC; Evans MJ
Mol Imaging Biol; 2020 Feb; 22(1):208-216. PubMed ID: 30993558
[TBL] [Abstract][Full Text] [Related]
32. Detection of sub-centimeter lesions using digital TOF-PET/CT system combined with Bayesian penalized likelihood reconstruction algorithm.
Miwa K; Wagatsuma K; Nemoto R; Masubuchi M; Kamitaka Y; Yamao T; Hiratsuka S; Yamaguchi M; Yoshii T; Kobayashi R; Miyaji N; Ishii K
Ann Nucl Med; 2020 Oct; 34(10):762-771. PubMed ID: 32623569
[TBL] [Abstract][Full Text] [Related]
33. Simultaneous 99mTc-MDP/123I-MIBG tumor imaging using SPECT-CT: phantom and constructed patient studies.
Rakvongthai Y; El Fakhri G; Lim R; Bonab AA; Ouyang J
Med Phys; 2013 Oct; 40(10):102506. PubMed ID: 24089927
[TBL] [Abstract][Full Text] [Related]
34. Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.
Okuda K; Nakajima K; Yamada M; Wakabayashi H; Ichikawa H; Arai H; Matsuo S; Taki J; Hashimoto M; Kinuya S
Ann Nucl Med; 2014 Jan; 28(1):60-8. PubMed ID: 24214735
[TBL] [Abstract][Full Text] [Related]
35. Physical performance of the new hybrid PET∕CT Discovery-690.
Bettinardi V; Presotto L; Rapisarda E; Picchio M; Gianolli L; Gilardi MC
Med Phys; 2011 Oct; 38(10):5394-411. PubMed ID: 21992359
[TBL] [Abstract][Full Text] [Related]
36. A modified OSEM algorithm for PET reconstruction using wavelet processing.
Lee NY; Choi Y
Comput Methods Programs Biomed; 2005 Dec; 80(3):236-45. PubMed ID: 16274838
[TBL] [Abstract][Full Text] [Related]
37. Characterization and simulation of noise in PET images reconstructed with OSEM: Development of a method for the generation of synthetic images.
Castro P; Huerga C; Chamorro P; Garayoa J; Roch M; Pérez L
Rev Esp Med Nucl Imagen Mol (Engl Ed); 2018; 37(4):229-236. PubMed ID: 29678630
[TBL] [Abstract][Full Text] [Related]
38. A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction.
Merlin T; Visvikis D; Fernandez P; Lamare F
Med Phys; 2015 Feb; 42(2):804-19. PubMed ID: 25652494
[TBL] [Abstract][Full Text] [Related]
39. Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation.
Tong S; Alessio AM; Kinahan PE
Phys Med Biol; 2010 Mar; 55(5):1453-73. PubMed ID: 20150683
[TBL] [Abstract][Full Text] [Related]
40. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.
Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A
Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]