BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 19673217)

  • 1. The accuracy of the pencil beam convolution and anisotropic analytical algorithms in predicting the dose effects due to attenuation from immobilization devices and large air gaps.
    Gray A; Oliver LD; Johnston PN
    Med Phys; 2009 Jul; 36(7):3181-91. PubMed ID: 19673217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
    Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
    Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
    [TBL] [Abstract][Full Text] [Related]  

  • 3. SU-E-T-529: Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA).
    Rana S; Rogers K
    Med Phys; 2012 Jun; 39(6Part18):3827. PubMed ID: 28518491
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
    Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
    Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Photon scatter in portal images: accuracy of a fluence based pencil beam superposition algorithm.
    McCurdy BM; Pistorius S
    Med Phys; 2000 May; 27(5):913-22. PubMed ID: 10841394
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Testing of the analytical anisotropic algorithm for photon dose calculation.
    Van Esch A; Tillikainen L; Pyykkonen J; Tenhunen M; Helminen H; Siljamäki S; Alakuijala J; Paiusco M; Lori M; Huyskens DP
    Med Phys; 2006 Nov; 33(11):4130-48. PubMed ID: 17153392
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions.
    Oinam AS; Singh L
    J Appl Clin Med Phys; 2010 Aug; 11(4):3351. PubMed ID: 21081894
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations.
    Gagné IM; Zavgorodni S
    J Appl Clin Med Phys; 2006 Jun; 8(1):33-46. PubMed ID: 17592451
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films.
    Rana S; Pokharel S
    Gulf J Oncolog; 2013 Jul; 1(14):63-9. PubMed ID: 23996869
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber.
    Kesen ND; Akbas U; Koksal C; Bilge H
    J Xray Sci Technol; 2019; 27(2):361-369. PubMed ID: 30856153
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy.
    Shirey RJ; Wu HT
    J Appl Clin Med Phys; 2018 Jan; 19(1):164-173. PubMed ID: 29239528
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water.
    Fogliata A; Nicolini G; Vanetti E; Clivio A; Cozzi L
    Phys Med Biol; 2006 Mar; 51(6):1421-38. PubMed ID: 16510953
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison between measured and calculated dynamic wedge dose distributions using the anisotropic analytic algorithm and pencil-beam convolution.
    Caprile PF; Venencia CD; Besa P
    J Appl Clin Med Phys; 2006 Aug; 8(1):47-54. PubMed ID: 17592453
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm.
    Yoo S; Wu Q; O'Daniel J; Horton J; Yin FF
    Radiother Oncol; 2012 May; 103(2):172-7. PubMed ID: 22349127
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose prediction accuracy of anisotropic analytical algorithm and pencil beam convolution algorithm beyond high density heterogeneity interface.
    Rana SB
    South Asian J Cancer; 2013 Jan; 2(1):26-30. PubMed ID: 24455541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The accuracy of dose calculations by anisotropic analytical algorithms for stereotactic radiotherapy in nasopharyngeal carcinoma.
    Kan MW; Cheung JY; Leung LH; Lau BM; Yu PK
    Phys Med Biol; 2011 Jan; 56(2):397-413. PubMed ID: 21178236
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy.
    Hirata K; Nakamura M; Yoshimura M; Mukumoto N; Nakata M; Ito H; Inokuchi H; Matsuo Y; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2015 Jul; 16(4):52–64. PubMed ID: 26218997
    [TBL] [Abstract][Full Text] [Related]  

  • 18. SU-D-211-01: Effect of Immobilization/support Devices and Air Gap on Skin Doses for Stereotactic Body Radiotherapy with Abdominal Compression Device.
    Peng Y
    Med Phys; 2012 Jun; 39(6Part3):3610. PubMed ID: 28517396
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the Eclipse AAA algorithm at extended SSD.
    Hussain A; Villarreal-Barajas E; Brown D; Dunscombe P
    J Appl Clin Med Phys; 2010 Jun; 11(3):3213. PubMed ID: 20717088
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric evaluation of photon dose calculation under jaw and MLC shielding.
    Fogliata A; Clivio A; Vanetti E; Nicolini G; Belosi MF; Cozzi L
    Med Phys; 2013 Oct; 40(10):101706. PubMed ID: 24089896
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.