159 related articles for article (PubMed ID: 19692982)
1. Construction of anthropomorphic phantoms for use in dosimetry studies.
Winslow JF; Hyer DE; Fisher RF; Tien CJ; Hintenlang DE
J Appl Clin Med Phys; 2009 Aug; 10(3):195-204. PubMed ID: 19692982
[TBL] [Abstract][Full Text] [Related]
2. Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology.
Jones AK; Hintenlang DE; Bolch WE
Med Phys; 2003 Aug; 30(8):2072-81. PubMed ID: 12945973
[TBL] [Abstract][Full Text] [Related]
3. Three-Dimensional Printing for Construction of Tissue-Equivalent Anthropomorphic Phantoms and Determination of Conceptus Dose.
Hoerner MR; Maynard MR; Rajon DA; Bova FJ; Hintenlang DE
AJR Am J Roentgenol; 2018 Dec; 211(6):1283-1290. PubMed ID: 30354270
[TBL] [Abstract][Full Text] [Related]
4. Tomographic physical phantom of the newborn child with real-time dosimetry I. Methods and techniques for construction.
Jones AK; Simon TA; Bolch WE; Holman MM; Hintenlang DE
Med Phys; 2006 Sep; 33(9):3274-82. PubMed ID: 17022222
[TBL] [Abstract][Full Text] [Related]
5. Relative stopping power measurements to aid in the design of anthropomorphic phantoms for proton radiotherapy.
Grant RL; Summers PA; Neihart JL; Blatnica AP; Sahoo N; Gillin MT; Followill DS; Ibbott GS
J Appl Clin Med Phys; 2014 Mar; 15(2):4523. PubMed ID: 24710437
[TBL] [Abstract][Full Text] [Related]
6. Dynamic lung phantom commissioning for 4D dose assessment in proton therapy.
Kostiukhina N; Palmans H; Stock M; Georg D; Knäusl B
Phys Med Biol; 2019 Nov; 64(23):235001. PubMed ID: 31652424
[TBL] [Abstract][Full Text] [Related]
7. A customizable anthropomorphic phantom for dosimetric verification of 3D-printed lung, tissue, and bone density materials.
Tino RB; Yeo AU; Brandt M; Leary M; Kron T
Med Phys; 2022 Jan; 49(1):52-69. PubMed ID: 34796527
[TBL] [Abstract][Full Text] [Related]
8. Canine anatomic phantom for preclinical dosimetry in internal emitter therapy.
Padilla L; Lee C; Milner R; Shahlaee A; Bolch WE
J Nucl Med; 2008 Mar; 49(3):446-52. PubMed ID: 18287264
[TBL] [Abstract][Full Text] [Related]
9. The UF series of tomographic computational phantoms of pediatric patients.
Lee C; Williams JL; Lee C; Bolch WE
Med Phys; 2005 Dec; 32(12):3537-48. PubMed ID: 16475752
[TBL] [Abstract][Full Text] [Related]
10. Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.
Welch D; Harken AD; Randers-Pehrson G; Brenner DJ
Phys Med Biol; 2015 May; 60(9):3589-98. PubMed ID: 25860401
[TBL] [Abstract][Full Text] [Related]
11. An anthropomorphic multimodality (CT/MRI) head phantom prototype for end-to-end tests in ion radiotherapy.
Gallas RR; Hünemohr N; Runz A; Niebuhr NI; Jäkel O; Greilich S
Z Med Phys; 2015 Dec; 25(4):391-399. PubMed ID: 26189015
[TBL] [Abstract][Full Text] [Related]
12. Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models.
Lee C; Lodwick D; Hasenauer D; Williams JL; Lee C; Bolch WE
Phys Med Biol; 2007 Jun; 52(12):3309-33. PubMed ID: 17664546
[TBL] [Abstract][Full Text] [Related]
13. The ADAM-pelvis phantom-an anthropomorphic, deformable and multimodal phantom for MRgRT.
Niebuhr NI; Johnen W; Echner G; Runz A; Bach M; Stoll M; Giske K; Greilich S; Pfaffenberger A
Phys Med Biol; 2019 Feb; 64(4):04NT05. PubMed ID: 30630152
[TBL] [Abstract][Full Text] [Related]
14. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
[TBL] [Abstract][Full Text] [Related]
15. A tissue-equivalent phantom series for mammography dosimetry.
Argo WP; Hintenlang K; Hintenlang DE
J Appl Clin Med Phys; 2004; 5(4):112-9. PubMed ID: 15738925
[TBL] [Abstract][Full Text] [Related]
16. An anthropomorphic maxillofacial phantom using 3-dimensional printing, polyurethane rubber and epoxy resin for dental imaging and dosimetry.
Badiuk SR; Sasaki DK; Rickey DW
Dentomaxillofac Radiol; 2022 Jan; 51(1):20200323. PubMed ID: 34133225
[TBL] [Abstract][Full Text] [Related]
17. Feasibility and accuracy of UF/NCI phantoms and Monte Carlo retrospective dosimetry in children treated on National Wilms Tumor Study protocols.
Kalapurakal JA; Gopalakrishnan M; Mille M; Helenowski I; Peterson S; Rigsby C; Laurie F; Jung JW; Fitzgerald TJ; Lee C
Pediatr Blood Cancer; 2018 Dec; 65(12):e27395. PubMed ID: 30101560
[TBL] [Abstract][Full Text] [Related]
18. Toward automated and personalized organ dose determination in CT examinations - A comparison of two tissue characterization models for Monte Carlo organ dose calculation with a Therapy Planning System.
Källman HE; Traneus E; Ahnesjö A
Med Phys; 2019 Feb; 46(2):1012-1023. PubMed ID: 30582891
[TBL] [Abstract][Full Text] [Related]
19. Manufacturing and evaluation of a multi-purpose Iranian head and neck anthropomorphic phantom called MIHAN.
Ahmadi M; Ramezani Anarestani M; Hariri Tabrizi S; Azma Z
Med Biol Eng Comput; 2021 Aug; 59(7-8):1611-1620. PubMed ID: 34268670
[TBL] [Abstract][Full Text] [Related]
20. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry.
MacDougall ND; Pitchford WG; Smith MA
Phys Med Biol; 2002 Oct; 47(20):R107-21. PubMed ID: 12433119
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]