These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 19693398)
21. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow. Saxena R; Lemmon J; Ellis J; Yoganathan A J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943 [TBL] [Abstract][Full Text] [Related]
22. Three-dimensional flow images by reconstruction from two-dimensional vector velocity maps. Bohs LN; Friemel BH; Kisslo J; Harfe DT; Nightingale KR; Trahey GE J Am Soc Echocardiogr; 1995; 8(6):915-23. PubMed ID: 8611292 [TBL] [Abstract][Full Text] [Related]
23. Velocity measurement accuracy in optical microhemodynamics: experiment and simulation. Chayer B; L Pitts K; Cloutier G; Fenech M Physiol Meas; 2012 Oct; 33(10):1585-602. PubMed ID: 22945542 [TBL] [Abstract][Full Text] [Related]
24. In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles. Lima R; Wada S; Takeda M; Tsubota K; Yamaguchi T J Biomech; 2007; 40(12):2752-7. PubMed ID: 17399723 [TBL] [Abstract][Full Text] [Related]
25. Temperature and velocity measurement fields of fluids using a schlieren system. Martínez-González A; Guerrero-Viramontes JA; Moreno-Hernández D Appl Opt; 2012 Jun; 51(16):3519-25. PubMed ID: 22695589 [TBL] [Abstract][Full Text] [Related]
26. Particle Image Velocimetry of Oil-Water Two-Phase Flow with High Water Cut and Low Flow Velocity in a Horizontal Small-Diameter Pipe. Han L; Wang H; Liu X; Xie R; Mu H; Fu C Sensors (Basel); 2019 Jun; 19(12):. PubMed ID: 31208105 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of magnetic resonance velocimetry for steady flow. Ku DN; Biancheri CL; Pettigrew RI; Peifer JW; Markou CP; Engels H J Biomech Eng; 1990 Nov; 112(4):464-72. PubMed ID: 2273875 [TBL] [Abstract][Full Text] [Related]
28. Simultaneous three-dimensional velocimetry and thermometry in gaseous flows using the stereoscopic vibrationally excited nitric oxide monitoring technique. Pan F; Sánchez-González R; McIlvoy MH; Bowersox RD; North SW Opt Lett; 2016 Apr; 41(7):1376-9. PubMed ID: 27192240 [TBL] [Abstract][Full Text] [Related]
29. 3-D Velocity and Volume Flow Measurement In Vivo Using Speckle Decorrelation and 2-D High-Frame-Rate Contrast-Enhanced Ultrasound. Zhou X; Leow CH; Rowland E; Riemer K; Rubin JM; Weinberg PD; Tang MX IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Dec; 65(12):2233-2244. PubMed ID: 29994672 [TBL] [Abstract][Full Text] [Related]
30. Inter-Laboratory Characterization of the Velocity Field in the FDA Blood Pump Model Using Particle Image Velocimetry (PIV). Hariharan P; Aycock KI; Buesen M; Day SW; Good BC; Herbertson LH; Steinseifer U; Manning KB; Craven BA; Malinauskas RA Cardiovasc Eng Technol; 2018 Dec; 9(4):623-640. PubMed ID: 30291585 [TBL] [Abstract][Full Text] [Related]
31. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses. Akutsu T; Saito J J Artif Organs; 2006; 9(3):165-78. PubMed ID: 16998702 [TBL] [Abstract][Full Text] [Related]
32. Complex flow patterns in a real-size intracranial aneurysm phantom: phase contrast MRI compared with particle image velocimetry and computational fluid dynamics. van Ooij P; Guédon A; Poelma C; Schneiders J; Rutten MC; Marquering HA; Majoie CB; VanBavel E; Nederveen AJ NMR Biomed; 2012 Jan; 25(1):14-26. PubMed ID: 21480417 [TBL] [Abstract][Full Text] [Related]
34. In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. Vennemann P; Kiger KT; Lindken R; Groenendijk BC; Stekelenburg-de Vos S; ten Hagen TL; Ursem NT; Poelmann RE; Westerweel J; Hierck BP J Biomech; 2006; 39(7):1191-200. PubMed ID: 15896796 [TBL] [Abstract][Full Text] [Related]
35. Measurement of a velocity field in microvessels using a high resolution PIV technique. Sugii Y; Nishio S; Okamoto K Ann N Y Acad Sci; 2002 Oct; 972():331-6. PubMed ID: 12496037 [TBL] [Abstract][Full Text] [Related]
36. Doppler pressure field deduced from the Doppler velocity field in an observation plane in a fluid. Ohtsuki S; Tanaka M Ultrasound Med Biol; 2003 Oct; 29(10):1431-8. PubMed ID: 14597340 [TBL] [Abstract][Full Text] [Related]
37. Flow and transport effect caused by the stalk contraction cycle of Zhou J; Ryu S; Admiraal D Biomicrofluidics; 2017 May; 11(3):034119. PubMed ID: 28670352 [No Abstract] [Full Text] [Related]
38. Optimal Plane Selection for Measuring Post-prandial Blood Flow Increase within the Superior Mesenteric Artery: Analysis Using 4D Flow and Computational Fluid Dynamics. Sugiyama M; Takehara Y; Kawate M; Ooishi N; Terada M; Isoda H; Sakahara H; Naganawa S; Johnson KM; Wieben O; Wakayama T; Nozaki A; Kabasawa H Magn Reson Med Sci; 2020 Dec; 19(4):366-374. PubMed ID: 32009062 [TBL] [Abstract][Full Text] [Related]
39. In vitro flow investigations in the aortic arch during cardiopulmonary bypass with stereo-PIV. Büsen M; Kaufmann TA; Neidlin M; Steinseifer U; Sonntag SJ J Biomech; 2015 Jul; 48(10):2005-11. PubMed ID: 25907548 [TBL] [Abstract][Full Text] [Related]
40. Acoustic radiation- and streaming-induced microparticle velocities determined by microparticle image velocimetry in an ultrasound symmetry plane. Barnkob R; Augustsson P; Laurell T; Bruus H Phys Rev E Stat Nonlin Soft Matter Phys; 2012 Nov; 86(5 Pt 2):056307. PubMed ID: 23214876 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]