508 related articles for article (PubMed ID: 19696700)
1. Transconjunctival 20-gauge pars plana vitrectomy using a single entry cannulated sutureless system.
Kim JE; Shah SN; Choi DL; Han DP; Connor TB
Retina; 2009 Oct; 29(9):1294-8. PubMed ID: 19696700
[TBL] [Abstract][Full Text] [Related]
2. Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy.
Woo SJ; Park KH; Hwang JM; Kim JH; Yu YS; Chung H
Retina; 2009 Apr; 29(4):456-63. PubMed ID: 19174725
[TBL] [Abstract][Full Text] [Related]
3. Postoperative complications and intraocular pressure in 943 consecutive cases of 23-gauge transconjunctival pars plana vitrectomy with 1-year follow-up.
Parolini B; Prigione G; Romanelli F; Cereda MG; Sartore M; Pertile G
Retina; 2010 Jan; 30(1):107-11. PubMed ID: 19816241
[TBL] [Abstract][Full Text] [Related]
4. Closure of sclerotomies after 25- and 23-gauge transconjunctival sutureless pars plana vitrectomy evaluated by optical coherence tomography.
Sawada T; Kakinoki M; Sawada O; Kawamura H; Ohji M
Ophthalmic Res; 2011; 45(3):122-8. PubMed ID: 20847574
[TBL] [Abstract][Full Text] [Related]
5. Outcomes and complications of rhegmatogenous retinal detachment repair with selective sutureless 25-gauge pars plana vitrectomy.
Bourla DH; Bor E; Axer-Siegel R; Mimouni K; Weinberger D
Am J Ophthalmol; 2010 Apr; 149(4):630-634.e1. PubMed ID: 20138604
[TBL] [Abstract][Full Text] [Related]
6. A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery.
Oshima Y; Wakabayashi T; Sato T; Ohji M; Tano Y
Ophthalmology; 2010 Jan; 117(1):93-102.e2. PubMed ID: 19880185
[TBL] [Abstract][Full Text] [Related]
7. A NOVEL TECHNIQUE FOR SECURING SCLEROTOMIES IN 20-GAUGE TRANSCONJUNCTIVAL PARS PLANA VITRECTOMY: Surgical Outcomes and Complications in 529 Consecutive Cases.
Abouammoh MA; Abouammoh MA; Gale JS; Arevalo JF; Sharma S
Retina; 2016 May; 36(5):974-80. PubMed ID: 26509222
[TBL] [Abstract][Full Text] [Related]
8. Safety of 20-gauge transconjunctival sutureless vitrectomy.
Papaefthymiou I; Petropoulos IK; Mangioris G; Mendrinos E; Pournaras CJ
Ophthalmologica; 2013; 230(4):207-14. PubMed ID: 24029384
[TBL] [Abstract][Full Text] [Related]
9. Rate of sclerotomy suturing in 23-gauge primary vitrectomy.
Duval R; Hui JM; Rezaei KA
Retina; 2014 Apr; 34(4):679-83. PubMed ID: 23975007
[TBL] [Abstract][Full Text] [Related]
10. Modified 20-gauge sutureless single-step sclerotomies for pars plana vitrectomy.
Saad A; Assi A
Retina; 2009 Jun; 29(6):848-53. PubMed ID: 19516122
[No Abstract] [Full Text] [Related]
11. Oblique sclerotomy technique for prevention of incompetent wound closure in transconjunctival 25-gauge vitrectomy.
López-Guajardo L; Pareja-Esteban J; Teus-Guezala MA
Am J Ophthalmol; 2006 Jun; 141(6):1154-6. PubMed ID: 16765698
[TBL] [Abstract][Full Text] [Related]
12. Short-term safety of 23-gauge single-step transconjunctival vitrectomy surgery.
Chieh JJ; Rogers AH; Wiegand TW; Baumal CR; Reichel E; Duker JS
Retina; 2009; 29(10):1486-90. PubMed ID: 19696698
[TBL] [Abstract][Full Text] [Related]
13. Visual outcomes with 23-gauge transconjunctival sutureless vitrectomy.
Tewari A; Shah GK; Fang A
Retina; 2008 Feb; 28(2):258-62. PubMed ID: 18301031
[TBL] [Abstract][Full Text] [Related]
14. Self-sealing sclerotomies for sutureless pars plana vitrectomy.
Rahman R; Rosen PH; Riddell C; Towler H
Ophthalmic Surg Lasers; 2000; 31(6):462-6. PubMed ID: 11095122
[TBL] [Abstract][Full Text] [Related]
15. Effect of intravitreal gas tamponade for sutureless vitrectomy wounds: three-dimensional corneal and anterior segment optical coherence tomography study.
Yamane S; Kadonosono K; Inoue M; Kobayashi S; Watanabe Y; Arakawa A
Retina; 2011 Apr; 31(4):702-6. PubMed ID: 21242862
[TBL] [Abstract][Full Text] [Related]
16. Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study.
Takashina H; Watanabe A; Tsuneoka H
BMC Ophthalmol; 2015 Dec; 15():171. PubMed ID: 26626403
[TBL] [Abstract][Full Text] [Related]
17. A novel technique of tangential, circumferential, scleral tunnel in 20-gauge transconjunctival sutureless vitrectomy: optical coherence tomography-aided analysis of wound integrity and clinical outcome.
Awan MA; Lyall DA; Koshy ZR
Br J Ophthalmol; 2012 Feb; 96(2):193-6. PubMed ID: 21653213
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of wound closure in oblique 23-gauge sutureless sclerotomies with visante optical coherence tomography.
Taban M; Sharma S; Ventura AA; Kaiser PK
Am J Ophthalmol; 2009 Jan; 147(1):101-107.e1. PubMed ID: 18835474
[TBL] [Abstract][Full Text] [Related]
19. Endophthalmitis after pars plana vitrectomy a 20- and 25-gauge comparison.
Hu AY; Bourges JL; Shah SP; Gupta A; Gonzales CR; Oliver SC; Schwartz SD
Ophthalmology; 2009 Jul; 116(7):1360-5. PubMed ID: 19576499
[TBL] [Abstract][Full Text] [Related]
20. Modified sutureless sclerotomies for pars plana vitrectomy.
Yeshurun I; Rock T; Bartov E
Am J Ophthalmol; 2004 Nov; 138(5):866-7. PubMed ID: 15531327
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]