These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 19699567)

  • 1. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws.
    Wang Y; Mori R; Ozoe N; Nakai T; Uchio Y
    Clin Biomech (Bristol, Avon); 2009 Nov; 24(9):781-5. PubMed ID: 19699567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct.
    DiPaola CP; Jacobson JA; Awad H; Conrad BP; Rechtine GR
    J Spinal Disord Tech; 2007 Jul; 20(5):369-73. PubMed ID: 17607102
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screw orientation and plate type (variable- vs. fixed-angle) effect strength of fixation for in vitro biomechanical testing of the Synthes CSLP.
    Dipaola CP; Jacobson JA; Awad H; Conrad BP; Rechtine GR
    Spine J; 2008; 8(5):717-22. PubMed ID: 17983846
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pullout strengths of cannulated and noncannulated cancellous bone screws.
    Thompson JD; Benjamin JB; Szivek JA
    Clin Orthop Relat Res; 1997 Aug; (341):241-9. PubMed ID: 9269180
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws.
    Brown GA; McCarthy T; Bourgeault CA; Callahan DJ
    J Orthop Res; 2000 Mar; 18(2):307-12. PubMed ID: 10815833
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of bone materials on the screw pull-out strength in human spine.
    Zhang QH; Tan SH; Chou SM
    Med Eng Phys; 2006 Oct; 28(8):795-801. PubMed ID: 16414303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fine thread versus coarse thread. A comparison of the maximum holding power.
    Gausepohl T; Möhring R; Pennig D; Koebke J
    Injury; 2001 Dec; 32 Suppl 4():SD1-7. PubMed ID: 11812471
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of pull-out force of unicortical versus bicortical screws in proximal phalanges of the hand: a human cadaveric study.
    Khalid M; Theivendran K; Cheema M; Rajaratnam V; Deshmukh SC
    Clin Biomech (Bristol, Avon); 2008 Nov; 23(9):1136-40. PubMed ID: 18649977
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models.
    Patel PS; Shepherd DE; Hukins DW
    Med Eng Phys; 2010 Oct; 32(8):822-8. PubMed ID: 20558097
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical tests and finite element models for bone holding power of tibial locking screws.
    Hou SM; Hsu CC; Wang JL; Chao CK; Lin J
    Clin Biomech (Bristol, Avon); 2004 Aug; 19(7):738-45. PubMed ID: 15288461
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface-bound bisphosphonates enhance screw fixation in rats--increasing effect up to 8 weeks after insertion.
    Wermelin K; Tengvall P; Aspenberg P
    Acta Orthop; 2007 Jun; 78(3):385-92. PubMed ID: 17611854
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of screw pullout rate on screw purchase in synthetic cancellous bone.
    Zdero R; Schemitsch EH
    J Biomech Eng; 2009 Feb; 131(2):024501. PubMed ID: 19102576
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors affecting the pullout strength of cancellous bone screws.
    Chapman JR; Harrington RM; Lee KM; Anderson PA; Tencer AF; Kowalski D
    J Biomech Eng; 1996 Aug; 118(3):391-8. PubMed ID: 8872262
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of thread pitch on pull-out strength of laparoscopic myoma screws.
    Tintara H; Aiyarak P; Mitarnun W; Geater A
    J Obstet Gynaecol Res; 2006 Aug; 32(4):428-33. PubMed ID: 16882270
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws.
    Seebeck J; Goldhahn J; Städele H; Messmer P; Morlock MM; Schneider E
    J Orthop Res; 2004 Nov; 22(6):1237-42. PubMed ID: 15475203
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses.
    Chao CK; Hsu CC; Wang JL; Lin J
    J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Experimental studies of the biomechanics of scaphoid screws].
    Kaudela KH; Berger W; Lugner P; Wozasek GE
    Unfallchirurg; 1996 Feb; 99(2):130-5. PubMed ID: 8881229
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Holding power of orthopedic screws in the large metacarpal and metatarsal bones of calves.
    Blikslager AT; Bowman KF; Abrams CF; Seaboch TR; Hunt EL
    Am J Vet Res; 1994 Mar; 55(3):415-8. PubMed ID: 8192269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone.
    Battula S; Schoenfeld AJ; Sahai V; Vrabec GA; Tank J; Njus GO
    J Trauma; 2008 Apr; 64(4):990-5. PubMed ID: 18404066
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing bending strength of tibial locking screws: mechanical tests and finite element analyses.
    Chao CK; Hsu CC; Wang JL; Lin J
    Clin Biomech (Bristol, Avon); 2007 Jan; 22(1):59-66. PubMed ID: 16959388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]