BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

594 related articles for article (PubMed ID: 19701090)

  • 1. Does the 40-Hz auditory steady-state response show the binaural masking level difference?
    Ishida IM; Stapells DR
    Ear Hear; 2009 Dec; 30(6):713-5. PubMed ID: 19701090
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Brain stem and cortical mechanisms underlying the binaural masking level difference in humans: an auditory steady-state response study.
    Wong WY; Stapells DR
    Ear Hear; 2004 Feb; 25(1):57-67. PubMed ID: 14770018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of contralateral noise on 40-Hz and 80-Hz auditory steady-state responses.
    Maki A; Kawase T; Kobayashi T
    Ear Hear; 2009 Oct; 30(5):584-9. PubMed ID: 19550336
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel type of auditory responses: temporal dynamics of 40-Hz steady-state responses induced by changes in sound localization.
    Ross B
    J Neurophysiol; 2008 Sep; 100(3):1265-77. PubMed ID: 18632891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neuromagnetic evaluation of binaural unmasking.
    Sasaki T; Kawase T; Nakasato N; Kanno A; Ogura M; Tominaga T; Kobayashi T
    Neuroimage; 2005 Apr; 25(3):684-9. PubMed ID: 15808969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multiple auditory steady-state response thresholds to bone-conduction stimuli in young infants with normal hearing.
    Small SA; Stapells DR
    Ear Hear; 2006 Jun; 27(3):219-28. PubMed ID: 16672791
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Human auditory steady state responses to binaural and monaural beats.
    Schwarz DW; Taylor P
    Clin Neurophysiol; 2005 Mar; 116(3):658-68. PubMed ID: 15721080
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effective masking levels for bone conduction auditory steady state responses in infants and adults with normal hearing.
    Hansen EE; Small SA
    Ear Hear; 2012; 33(2):257-66. PubMed ID: 21926629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Equivalent dipoles of the binaural interaction components and their comparison with binaurally evoked human auditory 40 Hz steady-state evoked potentials.
    Zaaroor M; Bleich N; Mittelman N; Pratt H
    Ear Hear; 2003 Jun; 24(3):248-56. PubMed ID: 12799547
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of auditory steady-state responses and auditory brainstem responses in audiometric assessment of adults with sensorineural hearing loss.
    Lin YH; Ho HC; Wu HP
    Auris Nasus Larynx; 2009 Apr; 36(2):140-5. PubMed ID: 18620826
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cortical steady-state responses to central and peripheral auditory beats.
    Draganova R; Ross B; Wollbrink A; Pantev C
    Cereb Cortex; 2008 May; 18(5):1193-200. PubMed ID: 17827173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neuromagnetic auditory steady-state responses to amplitude modulated sounds following dichotic or monaural presentation.
    Lazzouni L; Ross B; Voss P; Lepore F
    Clin Neurophysiol; 2010 Feb; 121(2):200-7. PubMed ID: 20005163
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparative study between auditory steady-state responses, auditory brain-stem responses and liminar tonal audiometry].
    Martínez Fernández A; Alañón Fernández MA; Ayala Martínez LF; Alvarez Alvarez AB; Miranda León MT; Sainz Quevedo M
    Acta Otorrinolaringol Esp; 2007; 58(7):290-5. PubMed ID: 17683695
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of across-frequency processes in dichotic listening conditions.
    Nitschmann M; Verhey JL; Kollmeier B
    J Acoust Soc Am; 2009 Dec; 126(6):3188-98. PubMed ID: 20000932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evidence for differential modulation of primary and nonprimary auditory cortex by forward masking in tinnitus.
    Roberts LE; Bosnyak DJ; Bruce IC; Gander PE; Paul BT
    Hear Res; 2015 Sep; 327():9-27. PubMed ID: 25937134
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Meta-analysis of variables that affect accuracy of threshold estimation via measurement of the auditory steady-state response (ASSR).
    Tlumak AI; Rubinstein E; Durrant JD
    Int J Audiol; 2007 Nov; 46(11):692-710. PubMed ID: 17978952
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Responses of neurons in the inferior colliculus to binaural masking level difference stimuli measured by rate-versus-level functions.
    Jiang D; McAlpine D; Palmer AR
    J Neurophysiol; 1997 Jun; 77(6):3085-106. PubMed ID: 9212259
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of 40 Hz auditory steady-state response (ASSR) and cortical auditory evoked potential (CAEP) thresholds in awake adult subjects.
    Tomlin D; Rance G; Graydon K; Tsialios I
    Int J Audiol; 2006 Oct; 45(10):580-8. PubMed ID: 17062499
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neuromagnetic responses to binaural beat in human cerebral cortex.
    Karino S; Yumoto M; Itoh K; Uno A; Yamakawa K; Sekimoto S; Kaga K
    J Neurophysiol; 2006 Oct; 96(4):1927-38. PubMed ID: 16790592
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection and differentiation of sensorineural hearing loss in mice using auditory steady-state responses and transient auditory brainstem responses.
    Pauli-Magnus D; Hoch G; Strenzke N; Anderson S; Jentsch TJ; Moser T
    Neuroscience; 2007 Nov; 149(3):673-84. PubMed ID: 17869440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.