These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 19705199)

  • 1. Thrombus formation after percutaneous catheterization and manual compression of the femoral artery in heparinized sheep.
    Kim YH; Pavcnik D; Kakizawa H; Uchida BT; Burke A; Loriaux M; Keller FS; Rosch J
    Cardiovasc Intervent Radiol; 2010 Apr; 33(2):321-9. PubMed ID: 19705199
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemostatic efficacy of chitosan-based bandage for closure of percutaneous arterial access sites: An experimental study in heparinized sheep model.
    Kranokpiraksa P; Pavcnik D; Kakizawa H; Uchida BT; Jeromel M; Keller FS; Rösch J
    Radiol Oncol; 2010 Jun; 44(2):86-91. PubMed ID: 22933896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Vascular hemostasis bandage compared to standard manual compression after cardiac catheterization in children.
    Waragai T; Morgan G; Ralston T; Chaturvedi R; Lee KJ; Benson L
    Catheter Cardiovasc Interv; 2011 Aug; 78(2):262-6. PubMed ID: 21538780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous vascular hemostasis device for interventional procedures.
    Merino A; Faulkner C; Corvalan A; Sanborn TA
    Cathet Cardiovasc Diagn; 1992 Aug; 26(4):319-22. PubMed ID: 1394422
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous femoral closure following stent-graft placement: use of the Perclose device.
    Quinn SF; Kim J
    Cardiovasc Intervent Radiol; 2004; 27(3):231-6. PubMed ID: 15037951
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical compression versus haemostatic wound dressing after femoral artery sheath removal: a prospective, randomized study.
    Schwarz T; Rastan A; Pochert V; Sixt S; Schwarzwälder U; Bürgelin KH; Büttner HJ; Müller C; Neumann FJ; Zeller T
    Vasa; 2009 Feb; 38(1):53-9. PubMed ID: 19229804
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.
    Sanborn TA; Gibbs HH; Brinker JA; Knopf WD; Kosinksi EJ; Roubin GS
    J Invasive Cardiol; 1999 Sep; 11 Suppl B():6B-13B. PubMed ID: 10745611
    [TBL] [Abstract][Full Text] [Related]  

  • 8. USage of chitosan for Femoral (USF) haemostasis after percutaneous procedures: a comparative open label study.
    Arbel J; Rozenbaum E; Reges O; Neuman Y; Levi A; Erel J; Haskia AR; Caneti M; Sherf M; Mosseri M
    EuroIntervention; 2011 Apr; 6(9):1104-9. PubMed ID: 21518684
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The brachial artery: a critical access for endovascular procedures.
    Alvarez-Tostado JA; Moise MA; Bena JF; Pavkov ML; Greenberg RK; Clair DG; Kashyap VS
    J Vasc Surg; 2009 Feb; 49(2):378-85; discussion 385. PubMed ID: 19028057
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of vascular closure devices vs manual compression after femoral artery puncture: the ISAR-CLOSURE randomized clinical trial.
    Schulz-Schüpke S; Helde S; Gewalt S; Ibrahim T; Linhardt M; Haas K; Hoppe K; Böttiger C; Groha P; Bradaric C; Schmidt R; Bott-Flügel L; Ott I; Goedel J; Byrne RA; Schneider S; Burgdorf C; Morath T; Kufner S; Joner M; Cassese S; Hoppmann P; Hengstenberg C; Pache J; Fusaro M; Massberg S; Mehilli J; Schunkert H; Laugwitz KL; Kastrati A;
    JAMA; 2014 Nov; 312(19):1981-7. PubMed ID: 25399273
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Manual versus mechanical compression for femoral artery hemostasis after cardiac catheterization.
    Simon A; Bumgarner B; Clark K; Israel S
    Am J Crit Care; 1998 Jul; 7(4):308-13. PubMed ID: 9656045
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The safety and efficacy of the StarClose Vascular Closure System: the ultrasound substudy of the CLIP study.
    Jaff MR; Hadley G; Hermiller JB; Simonton C; Hinohara T; Cannon L; Reisman M; Braden G; Fletcher DR; Zapien M; Chou TM; DiDonato K
    Catheter Cardiovasc Interv; 2006 Nov; 68(5):684-9. PubMed ID: 17039509
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of a 21G micropuncture needle and a regular 19G access needle for antegrade arterial access into the superficial femoral artery.
    Gutzeit A; Schoch E; Reischauer C; Hergan K; Jenelten R; Binkert CA
    Cardiovasc Intervent Radiol; 2014 Apr; 37(2):343-7. PubMed ID: 23839004
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility study of NeoMend, a percutaneous arterial closure device that uses a nonthrombogenic bioadhesive.
    Funovics MA; Wolf F; Philipp MO; Kee S; Tichy B; Dirisamer A; Rand T; Lammer J
    AJR Am J Roentgenol; 2003 Feb; 180(2):533-8. PubMed ID: 12540467
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of different methods for achieving hemostasis after arterial sheath removal.
    McConnell MK; McDilda K; Bridges R; Marsh N; Jenkins G; Dowdy J; Prasnikar M
    J Cardiovasc Nurs; 2012; 27(4):E1-5. PubMed ID: 21912270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and safety of antegrade common femoral artery access closure using the Angio-Seal device: experience with 1889 interventions for critical limb ischemia in diabetic patients.
    Lupattelli T; Tannouri F; Garaci FG; Papa G; Pangos M; Somalvico F; Caravaggi C; Faglia E
    J Endovasc Ther; 2010 Jun; 17(3):366-75. PubMed ID: 20557177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective study on ultrasound-guided compression therapy or thrombin injection for treatment of iatrogenic false aneurysms in patients receiving full-dose anti-platelet therapy.
    Görge G; Kunz T; Kirstein M
    Z Kardiol; 2003 Jul; 92(7):564-70. PubMed ID: 12883841
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Role of femoral vessel catheterization and altered hemostasis in the development of extraperitoneal hematomas: CT study in 44 patients.
    Quint LE; Holland D; Korobkin M; Cascade PN
    AJR Am J Roentgenol; 1993 Apr; 160(4):855-8. PubMed ID: 8456681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A randomized comparison of a novel bioabsorbable vascular closure device versus manual compression in the achievement of hemostasis after percutaneous femoral procedures: the ECLIPSE (Ensure's Vascular Closure Device Speeds Hemostasis Trial).
    Wong SC; Bachinsky W; Cambier P; Stoler R; Aji J; Rogers JH; Hermiller J; Nair R; Hutman H; Wang H;
    JACC Cardiovasc Interv; 2009 Aug; 2(8):785-93. PubMed ID: 19695549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Evaluation of a hemostatic device with percutaneous collagen application (VasoSeal) compared to a mechanical compression system (Compressar) after transfemoral catheterization of patients suffering from arterial occlusive disease].
    Neudecker A; Manke C; Lenhart M; Zorger N; Paetzel C; Feuerbach S; Link J
    Rofo; 2003 May; 175(5):676-81. PubMed ID: 12743862
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.