These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
221 related articles for article (PubMed ID: 19714380)
21. Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation. Pittman SD; Ayas NT; MacDonald MM; Malhotra A; Fogel RB; White DP Sleep; 2004 Aug; 27(5):923-33. PubMed ID: 15453551 [TBL] [Abstract][Full Text] [Related]
22. Is portable monitoring for diagnosing obstructive sleep apnea syndrome suitable in elderly population? Polese JF; Santos-Silva R; de Oliveira Ferrari PM; Sartori DE; Tufik S; Bittencourt L Sleep Breath; 2013 May; 17(2):679-86. PubMed ID: 22752758 [TBL] [Abstract][Full Text] [Related]
23. Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Chinese Adults. Xu L; Han F; Keenan BT; Kneeland-Szanto E; Yan H; Dong X; Chang Y; Zhao L; Zhang X; Li J; Pack AI; Kuna ST J Clin Sleep Med; 2017 May; 13(5):675-683. PubMed ID: 28356181 [TBL] [Abstract][Full Text] [Related]
24. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. Rofail LM; Wong KK; Unger G; Marks GB; Grunstein RR Sleep; 2010 Aug; 33(8):1106-14. PubMed ID: 20815194 [TBL] [Abstract][Full Text] [Related]
25. Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP. Desai H; Patel A; Patel P; Grant BJ; Mador MJ Sleep Breath; 2009 Nov; 13(4):383-90. PubMed ID: 19408029 [TBL] [Abstract][Full Text] [Related]
26. Validation of the MediByte® type 3 portable monitor compared with polysomnography for screening of obstructive sleep apnea. Driver HS; Pereira EJ; Bjerring K; Toop F; Stewart SC; Munt PW; Fitzpatrick MF Can Respir J; 2011; 18(3):137-43. PubMed ID: 21766076 [TBL] [Abstract][Full Text] [Related]
27. Assessment of Mandibular Movement Monitoring With Machine Learning Analysis for the Diagnosis of Obstructive Sleep Apnea. Pépin JL; Letesson C; Le-Dong NN; Dedave A; Denison S; Cuthbert V; Martinot JB; Gozal D JAMA Netw Open; 2020 Jan; 3(1):e1919657. PubMed ID: 31968116 [TBL] [Abstract][Full Text] [Related]
28. [Utility of the type 3 portable monitor for the diagnosis of patients with obstructive sleep apnea]. Wen YF; Chang Y; Xu LY; Dong XS; Zhao L; Zhang XL; Li J; Zuo YH; Zhang W; Gao YH; Han F Zhonghua Yi Xue Za Zhi; 2019 Oct; 99(38):2994-2999. PubMed ID: 31607031 [No Abstract] [Full Text] [Related]
29. Diagnosis of obstructive sleep apnea by peripheral arterial tonometry: meta-analysis. Yalamanchali S; Farajian V; Hamilton C; Pott TR; Samuelson CG; Friedman M JAMA Otolaryngol Head Neck Surg; 2013 Dec; 139(12):1343-50. PubMed ID: 24158564 [TBL] [Abstract][Full Text] [Related]
30. Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea. BaHammam AS; Sharif M; Gacuan DE; George S Med Sci Monit; 2011 Feb; 17(2):MT13-9. PubMed ID: 21278698 [TBL] [Abstract][Full Text] [Related]
31. Validation of a portable monitoring system for the diagnosis of obstructive sleep apnea syndrome. Santos-Silva R; Sartori DE; Truksinas V; Truksinas E; Alonso FF; Tufik S; Bittencourt LR Sleep; 2009 May; 32(5):629-36. PubMed ID: 19480230 [TBL] [Abstract][Full Text] [Related]
32. Diagnosis and initial management of obstructive sleep apnea without polysomnography: a randomized validation study. Mulgrew AT; Fox N; Ayas NT; Ryan CF Ann Intern Med; 2007 Feb; 146(3):157-66. PubMed ID: 17283346 [TBL] [Abstract][Full Text] [Related]
33. Reliability of SleepStrip as a screening test in obstructive sleep apnea patients. Dinç AE; Yılmaz M; Tutar H; Aydil U; Kızıl Y; Damar M; Kemaloğlu YK Eur Arch Otorhinolaryngol; 2014 Oct; 271(10):2813-8. PubMed ID: 24861563 [TBL] [Abstract][Full Text] [Related]
34. Validation of the screening tool ApneaLink Stehling F; Keull J; Olivier M; Große-Onnebrink J; Mellies U; Stuck BA Sleep Med; 2017 Sep; 37():13-18. PubMed ID: 28899523 [TBL] [Abstract][Full Text] [Related]
35. [Utility of portable monitoring device with airflow, oxygen saturation and respiratory effort in the diagnosis of sleep apnea hypopnea syndrome]. Yan H; Dong XS; Li YQ; Liu YN; Li J; An P; Zhao L; Gao ZC; Han F Zhonghua Yi Xue Za Zhi; 2013 Feb; 93(6):415-8. PubMed ID: 23660258 [TBL] [Abstract][Full Text] [Related]
36. Short-Term Variability in Apnea-Hypopnea Index during Extended Home Portable Monitoring. Prasad B; Usmani S; Steffen AD; Van Dongen HP; Pack FM; Strakovsky I; Staley B; Dinges D; Maislin G; Pack AI; Weaver TE J Clin Sleep Med; 2016 Jun; 12(6):855-63. PubMed ID: 26857059 [TBL] [Abstract][Full Text] [Related]
37. Nasal pressure recordings to detect obstructive sleep apnea. de Almeida FR; Ayas NT; Otsuka R; Ueda H; Hamilton P; Ryan FC; Lowe AA Sleep Breath; 2006 Jun; 10(2):62-9. PubMed ID: 16502297 [TBL] [Abstract][Full Text] [Related]
38. An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea. Goodrich S; Orr WC Sleep Med; 2009 Jan; 10(1):118-22. PubMed ID: 18083629 [TBL] [Abstract][Full Text] [Related]
39. [Evaluation of a portable device based on peripheral arterial tone in the detection of obstructive sleep apnea]. Zhang J; Wang CY; Wang NY; Liu JQ; Du JY; Zhou GX; Yan ZF; Wen XH; Li L; Liu JF Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2012 Feb; 47(2):112-6. PubMed ID: 22455808 [TBL] [Abstract][Full Text] [Related]