318 related articles for article (PubMed ID: 19719487)
1. Use of radiofrequency perforation for lead placement in biventricular or conventional endocardial pacing after mustard or senning operations for D-transposition of the great arteries.
Chakrabarti S; Szantho G; Turner MS; Stuart G; Martin RP
Pacing Clin Electrophysiol; 2009 Sep; 32(9):1123-9. PubMed ID: 19719487
[TBL] [Abstract][Full Text] [Related]
2. An approach to ablate and pace:AV junction ablation and pacemaker implantation performed concurrently from the same venous access site.
Issa ZF
Pacing Clin Electrophysiol; 2007 Sep; 30(9):1116-20. PubMed ID: 17725755
[TBL] [Abstract][Full Text] [Related]
3. A novel approach for endocardial resynchronization therapy: initial experience with transapical implantation of the left ventricular lead.
Kassai I; Mihalcz A; Foldesi C; Kardos A; Szili-Torok T
Heart Surg Forum; 2009 Jun; 12(3):E137-40. PubMed ID: 19546062
[TBL] [Abstract][Full Text] [Related]
4. Video-assisted thoracoscopic implantation of the left ventricular pacing lead for cardiac resynchronization therapy.
Jutley RS; Waller DA; Loke I; Skehan D; Ng A; Stafford P; Chin D; Spyt TJ
Pacing Clin Electrophysiol; 2008 Jul; 31(7):812-8. PubMed ID: 18684277
[TBL] [Abstract][Full Text] [Related]
5. Successful balloon dilatation of the valve of Vieussens for left ventricular lead placement.
Hasdemir C; Alp A; Can LH
Pacing Clin Electrophysiol; 2009 Jun; 32(6):828-9. PubMed ID: 19545352
[TBL] [Abstract][Full Text] [Related]
6. Preprocedural imaging in patients with transposition of the great arteries facilitates placement of cardiac resynchronization therapy leads.
Ruckdeschel ES; Quaife R; Lewkowiez L; Kay J; Sauer WH; Collins KK; Nguyen DT
Pacing Clin Electrophysiol; 2014 May; 37(5):546-53. PubMed ID: 24313876
[TBL] [Abstract][Full Text] [Related]
7. Permanent pacing using a coronary sinus lead in a patient with univentricular physiology: an extended application of biventricular pacing technology.
Hsieh MJ; Yeh KH; Satish OS; Wang CC
Europace; 2006 Feb; 8(2):147-50. PubMed ID: 16627429
[TBL] [Abstract][Full Text] [Related]
8. Left ventricular dysfunction after cardiac resynchronization therapy in congenital heart disease patients with a failing systemic right ventricle.
Kiesewetter C; Michael K; Morgan J; Veldtman GR
Pacing Clin Electrophysiol; 2008 Feb; 31(2):159-62. PubMed ID: 18233967
[TBL] [Abstract][Full Text] [Related]
9. Usefulness of a pacing guidewire to facilitate left ventricular lead implantation in cardiac resynchronization therapy.
de Cock CC; Res JC; Hendriks ML; Allaart CP
Pacing Clin Electrophysiol; 2009 Apr; 32(4):446-9. PubMed ID: 19335852
[TBL] [Abstract][Full Text] [Related]
10. Interventions in leaks and obstructions of the interatrial baffle late after Mustard and Senning correction for transposition of the great arteries.
Daehnert I; Hennig B; Wiener M; Rotzsch C
Catheter Cardiovasc Interv; 2005 Nov; 66(3):400-7. PubMed ID: 16208709
[TBL] [Abstract][Full Text] [Related]
11. [Stenosis of the superior caval canal after Mustard and Senning procedures: treatment by dilatation and stent implantation. Two case reports].
Villain E; Saliba Z; Bonhoeffer P; Iserin L; Bonnet D; Kachaner J
Arch Mal Coeur Vaiss; 2001 Feb; 94(2):139-43. PubMed ID: 11265552
[TBL] [Abstract][Full Text] [Related]
12. [Clinical analysis of surgical procedures and outcomes for corrected transposition of great arteries with heart anomaly].
Fang MH; Zhu HY; Wang ZW; Song HC; Zhang NB; Zhe J
Zhonghua Wai Ke Za Zhi; 2008 Apr; 46(8):570-3. PubMed ID: 18844048
[TBL] [Abstract][Full Text] [Related]
13. Nontraditional surgical approaches for implantation of pacemaker and cardioverter defibrillator systems in patients with limited venous access.
Jaroszewski DE; Altemose GT; Scott LR; Srivasthan K; Devaleria PA; Lackey J; Arabia FA
Ann Thorac Surg; 2009 Jul; 88(1):112-6. PubMed ID: 19559206
[TBL] [Abstract][Full Text] [Related]
14. Rescue permanent iliac vein pacing after epicardial lead failure: an unusual reversal of pacing fortune.
Gupta A; Halleran SM; Krishnan K; Trohman RG
Europace; 2008 Oct; 10(10):1236-8. PubMed ID: 18606617
[TBL] [Abstract][Full Text] [Related]
15. Implantation of left ventricular leads using a telescopic catheter system.
Zanon F; Baracca E; Pastore G; Aggio S; Rigatelli G; Dondina C; Marras G; Braggion G; Boaretto G; Cardaioli P; Galasso M; Zonzin P; Barold SS
Pacing Clin Electrophysiol; 2006 Nov; 29(11):1266-72. PubMed ID: 17100682
[TBL] [Abstract][Full Text] [Related]
16. Biventricular device implantation in a patient with congenitally corrected transposition and left-sided superior vena cava.
Rogers DP; Walker F; Chow AW; Lambiase PD
Pacing Clin Electrophysiol; 2008 Apr; 31(4):499-502. PubMed ID: 18373771
[TBL] [Abstract][Full Text] [Related]
17. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.
Hofferberth SC; Alexander ME; Mah DY; Bautista-Hernandez V; del Nido PJ; Fynn-Thompson F
J Thorac Cardiovasc Surg; 2016 Jan; 151(1):131-8. PubMed ID: 26410005
[TBL] [Abstract][Full Text] [Related]
18. A novel approach to transvenous dual-chamber pacing lead placement and cardiac defibrillator implantation after tricuspid valve replacement.
Lopez JA; Lufschanowski R
J Cardiovasc Electrophysiol; 2008 Aug; 19(8):873-5. PubMed ID: 18179526
[TBL] [Abstract][Full Text] [Related]
19. Radiofrequency-assisted transseptal perforation for electrophysiology procedures in children and adults with repaired congenital heart disease.
Esch JJ; Triedman JK; Cecchin F; Alexander ME; Walsh EP
Pacing Clin Electrophysiol; 2013 May; 36(5):607-11. PubMed ID: 23380019
[TBL] [Abstract][Full Text] [Related]
20. Transvenous pacing via a disconnected superior vena cava in a patient with transposition of the great arteries.
Steadman CD; Clift P; Thorne SA; De Giovanni JV
Pacing Clin Electrophysiol; 2008 Sep; 31(9):1226-8. PubMed ID: 18834479
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]