These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 19730010)

  • 1. Urgent exchange of a HeartMate II left ventricular assist device after percutaneous lead fracture.
    Jafar M; Gregoric ID; Radovancevic R; Cohn WE; McGuire N; Frazier OH
    ASAIO J; 2009; 55(5):523-4. PubMed ID: 19730010
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
    John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
    Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Late-onset driveline infections: the Achilles' heel of prolonged left ventricular assist device support.
    Zierer A; Melby SJ; Voeller RK; Guthrie TJ; Ewald GA; Shelton K; Pasque MK; Moon MR; Damiano RJ; Moazami N
    Ann Thorac Surg; 2007 Aug; 84(2):515-20. PubMed ID: 17643627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.
    John R; Kamdar F; Liao K; Colvin-Adams M; Miller L; Joyce L; Boyle A
    J Thorac Cardiovasc Surg; 2008 Nov; 136(5):1318-23. PubMed ID: 19026822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heartmate II axial-flow left ventricular assist system: management, clinical review and personal experience.
    Loforte A; Montalto A; Ranocchi F; Casali G; Luzi G; Monica PL; Sbaraglia F; Polizzi V; Distefano G; Musumeci F
    J Cardiovasc Med (Hagerstown); 2009 Oct; 10(10):765-71. PubMed ID: 19465866
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved durability of the HeartMate XVE left ventricular assist device provides safe mechanical support up to 1 year but is associated with high risk of device failure in the second year.
    Martin J; Friesewinkel O; Benk C; Sorg S; Schultz S; Beyersdorf F
    J Heart Lung Transplant; 2006 Apr; 25(4):384-90. PubMed ID: 16563965
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical experience with sternotomy versus subcostal approach for exchange of the HeartMate XVE to the HeartMate II ventricular assist device.
    Gregoric ID; Bruckner BA; Jacob L; Kar B; Cohn WE; La Francesca S; Frazier OH
    Ann Thorac Surg; 2008 May; 85(5):1646-9. PubMed ID: 18442556
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.
    Patel ND; Weiss ES; Schaffer J; Ullrich SL; Rivard DC; Shah AS; Russell SD; Conte JV
    Ann Thorac Surg; 2008 Sep; 86(3):832-40; discussion 832-40. PubMed ID: 18721570
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Urgent pump exchange for stroke resulting from a distorted HeartMate XVE inflow conduit.
    Frazier OH; Forrester MD; Gemmato C; Gregoric ID
    J Heart Lung Transplant; 2007 Jun; 26(6):646-8. PubMed ID: 17543792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. HeartMate left ventricular assist system exchange: results and technical considerations.
    Adamson RM; Dembitsky WP; Baradarian S; Chammas J; Jaski B; Hoagland P; McCalmont V; Ortiz K; Stahovich M; Chillcott S
    ASAIO J; 2009; 55(6):598-601. PubMed ID: 19779301
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and clinical management of life-threatening left ventricular assist device failure.
    Birks EJ; Tansley PD; Yacoub MH; Bowles CT; Hipkin M; Hardy J; Banner NR; Khaghani A
    J Heart Lung Transplant; 2004 Aug; 23(8):964-9. PubMed ID: 15312826
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Exchange techniques for implantable ventricular assist devices.
    Gregoric ID
    ASAIO J; 2008; 54(1):14-9. PubMed ID: 18204310
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Left ventricular mechanical assist devices and cardiac device interactions: an observational case series.
    Foo D; Walker BD; Kuchar DL; Thorburn CW; Tay A; Hayward CS; Macdonald P; Keogh A; Kotlyar E; Spratt P; Jansz P
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):879-87. PubMed ID: 19572863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Identification of device malfunction in patients supported with the HeartMate XVE left ventricular assist system.
    Haft JW; Suzuki Y; Aaronson KD; Dyke DB; Wright S; Poirier VL; Pagani FD
    ASAIO J; 2007; 53(3):298-303. PubMed ID: 17515718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality.
    Moazami N; Milano CA; John R; Sun B; Adamson RM; Pagani FD; Smedira N; Slaughter MS; Farrar DJ; Frazier OH;
    Ann Thorac Surg; 2013 Feb; 95(2):500-5. PubMed ID: 23261114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients.
    Kamdar F; Boyle A; Liao K; Colvin-adams M; Joyce L; John R
    J Heart Lung Transplant; 2009 Apr; 28(4):352-9. PubMed ID: 19332262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous lead dysfunction in the HeartMate II left ventricular assist device.
    Kalavrouziotis D; Tong MZ; Starling RC; Massiello A; Soltesz E; Smedira NG; Fryc R; Heatley G; Farrar DJ; Moazami N
    Ann Thorac Surg; 2014 Apr; 97(4):1373-8. PubMed ID: 24492061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Successful percutaneous management of acute left ventricular assist device stoppage.
    Chrysant GS; Horstmanshof DA; Snyder T; Chaffin JS; Elkins CC; Kanaly PJ; Long JW
    ASAIO J; 2010; 56(5):483-5. PubMed ID: 20811171
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.
    Malehsa D; Meyer AL; Bara C; Strüber M
    Eur J Cardiothorac Surg; 2009 Jun; 35(6):1091-3. PubMed ID: 19303790
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pump exchange for cable damage in patients supported with HeartMate II left ventricular assist device.
    Potapov EV; Kaufmann F; Stepanenko A; Hening E; Vierecke J; Löw A; Lehmkuhl E; Dranishnikov N; Hetzer R; Krabatsch T
    ASAIO J; 2012; 58(6):578-82. PubMed ID: 23103699
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.